title: Brewery Tank Blanketing Gas Analyser
url: https://www.sarveshanalytics.com/applications/brewery-winery-and-tank-blanketing.html
description: Tank blanketing gas analyser with ACCURRA-S 6030, 3015. Beer and wine tanks are blanketed to keep oxygen out. Made in Pune.
updated: 2026-11-02
source: html
---

Food, agriculture and cold chain

# CO2 and oxygen analysis for brewery, winery and tank blanketing

Beer and wine tanks are blanketed to keep oxygen out. Sarvesh supplies ACCURRA-S 6030, 3015, built in Pune, with sampling matched to the stream.

- ISO 9001:2015, certified by TÜV
- Designed and built in Pune since 2002
- Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO

 Quick answer

Use ACCURRA-S 6030, 3015. Beer and wine tanks are blanketed to keep oxygen out. Dissolved oxygen is a liquid-phase measurement and not covered.

Updated 2 November 2026 · Figures from Sarvesh datasheets

## The measurement and why it matters

Beer and wine tanks are blanketed to keep oxygen out. This is a good fit, with one configuration or sample-handling point to confirm before we quote.

In stores, packing lines and tanks, gas composition controls shelf life and quality: oxygen and CO2 in fruit stores, nitrogen purity in packaging, CO2 blanketing in tanks. A continuous reading replaces periodic manual checks.

These samples are usually clean and close to atmospheric pressure, so the sample pump matters. Models 3015 and M015 are supplied without one. Tell us the sample pressure and we will confirm the sample path and add a pump where it is needed.

Typical buyers in India: breweries, wineries. Where this matches your plant, send us the gas, range, pressure and temperature at the tapping point and we will confirm the analyser and sample path.

## Models and ranges

| Model | Measures | Range | Sensor and notes |
|---|---|---|---|
| 6030 | Carbon dioxide | 0 to 20 % or 0 to 100 % | NDIR |
| 3015 | Trace oxygen | 0 to 1000 ppm (min range 0 to 100 ppm) | Electrochemical; no internal pump, no auto-calibration |

## Process notes

### What the analyser reads here

Gases of interest: CO2, O2. Analyser fit: ACCURRA-S 6030, 3015.

The table above lists each model with its range; where a row says to confirm the range, we check it against the datasheet for your application before quoting.

### What to settle before ordering

Dissolved oxygen is a liquid-phase measurement and not covered.

We would rather confirm these points at the start than discover them at commissioning, so please include them with your process details.

## Related applications

This page overlaps with:

- [Fermenter and bioreactor off-gas](https://www.sarveshanalytics.com/applications/fermenter-and-bioreactor-off-gas.html)

## Sampling and installation

- Every ACCURRA-S has an internal fine filter and rotameter. Regulate sample pressure and flow externally; the catalogue recommends about 1 LPM and a sample pressure of 2 to 10 psig.
- Models 3015, M015, 3130 and 3190 are supplied without an internal sample pump. Tell us the sample pressure and we will confirm the sample path or add a pump.
- Models 3015 and M015 have no auto-calibration, so plan a calibration routine with the right reference gas.
- Keep sample lines short, clean and dry, and vent the sample somewhere safe.

ACCURRA-S sample specification: non-corrosive, non-toxic, non-flammable, non-condensing and dry, free from entrained oil; sample pressure 2 to 10 psig, regulated externally; flow about 1 LPM; dust below 3 micron. Where your sample differs, we design conditioning around it.

## Send us your process data

**What the data sheet asks for**

Send what you have and we will ask for the rest.

- The gases to measure, the range, and the accuracy you need
- Background gases and their typical composition
- Sample temperature, pressure and dew point at the tapping point
- Dust level, and whether the gas carries tar, oil or condensable vapour
- Process connection and, for ducts, the duct diameter
- Where the sample vents to, and at what pressure
- Area classification of the tapping point and of the analyser location, and the IP protection needed
- Distance between the tapping point and the analyser
- Outputs you need: 4-20 mA, dual range, relays, Modbus RTU
- Calibration approach, calibration gas available, and whether blowback is required
- Utilities at site: power supply, instrument air, nitrogen, steam and cooling water, and the ambient temperature range
- Gases and ranges: CO2, O2
- The point to confirm: Dissolved oxygen is a liquid-phase measurement and not covered.

## Recommended Sarvesh products

[

### ACCURRA-S

Trace, percent and purity analysis of O2, CO, CO2, CH4 and dew point. View ACCURRA-S

](https://www.sarveshanalytics.com/safe-gas-analyser.html)[

### SV-200 / SV-400 vaporisers

Vaporiser for cryogenic and wet samples. View SV-200 / SV-400 vaporisers

](https://www.sarveshanalytics.com/sample-vaporisers.html)

## Frequently asked questions

**Which analyser suits brewery, winery and tank blanketing?**

ACCURRA-S 6030, 3015 Beer and wine tanks are blanketed to keep oxygen out.

**What should I check before ordering for brewery, winery and tank blanketing?**

Dissolved oxygen is a liquid-phase measurement and not covered.

**Who typically needs this?**

Typical buyers in India: breweries, wineries.

**Can Sarvesh support a variation of this application?**

Yes. If your process differs from the usual case, send the details. Application engineering is where we start every project, and bespoke applications are welcome.

## More in Food, agriculture and cold chain

- [Controlled-atmosphere (CA and ULO) fruit stores](https://www.sarveshanalytics.com/applications/controlled-atmosphere-ca-and-ulo-fruit-stores.html)
- [Fruit ripening rooms](https://www.sarveshanalytics.com/applications/fruit-ripening-rooms.html)
- [Modified-atmosphere packaging gas mixer verification](https://www.sarveshanalytics.com/applications/modified-atmosphere-packaging-gas-mixer-verification.html)
- [Nitrogen supply purity for food and beverage packaging](https://www.sarveshanalytics.com/applications/nitrogen-supply-purity-for-food-and-beverage-packaging.html)
- [**All food, agriculture and cold chain applications**](https://www.sarveshanalytics.com/industries/food-agriculture-cold-chain-gas-analysers.html)
- [Browse analysers by gas](https://www.sarveshanalytics.com/gas-analyser.html)