title: Bright Annealing Furnace Hydrogen Analyser
url: https://www.sarveshanalytics.com/applications/bright-annealing-of-copper-tube-stainless-steel-and-wire.html
description: Bright annealing hydrogen analyser with ACCURRA-S M015 and ACCURRA-TCD. Hydrogen-nitrogen atmospheres and dew point set surface finish. Made in Pune.
updated: 2026-11-02
source: html
---

Steel, heat treatment and furnaces

# Hydrogen and dew point analysis for bright annealing of tube, strip and wire

Hydrogen-nitrogen atmospheres and dew point set surface finish. Sarvesh supplies ACCURRA-S M015 and ACCURRA-TCD, built in Pune, with sampling matched to the stream.

- ISO 9001:2015, certified by TÜV
- Designed and built in Pune since 2002
- Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO

 Quick answer

Use TCD (H2 in N2), M015. Hydrogen-nitrogen atmospheres and dew point set surface finish. Sampling after the furnace exit or muffle.

Updated 2 November 2026 · Figures from Sarvesh datasheets

## The measurement and why it matters

Hydrogen-nitrogen atmospheres and dew point set surface finish. This application matches the catalogue specification directly.

In furnaces, chambers and dry rooms the atmosphere is part of the recipe. A few ppm of oxygen, a dew point or a hydrogen share decides surface finish, yield or safety, and a leak or a drifting gas supply shows up in the analyser before it shows up in the product.

These atmospheres are usually clean at the analyser but can be hot, sooty or particulate-laden at the furnace take-off. Sample from the right point, keep lines short and use dry stainless tubing. Tell us the furnace or chamber volume and flow so we can confirm the sample path.

Typical buyers in India: copper tube makers, stainless strip and wire makers, bright-annealing furnace OEMs. Where this matches your plant, send us the gas, range, pressure and temperature at the tapping point and we will confirm the analyser and sample path.

## Models and ranges

| Model | Measures | Range | Sensor and notes |
|---|---|---|---|
| M015 | Dew point | -80 to +20 C | Ceramic sensor; no internal pump, no auto-calibration |
| ACCURRA-TCD | Binary gas analysis (H2, dew point) | Binary mixtures | Thermal conductivity, no reference gas |

## Process notes

### What the analyser reads here

Gases of interest: H2, dew point. Analyser fit: TCD (H2 in N2), M015.

The table above lists each model with its range; where a row says to confirm the range, we check it against the datasheet for your application before quoting.

### What to settle before ordering

Sampling after the furnace exit or muffle.

We would rather confirm these points at the start than discover them at commissioning, so please include them with your process details.

## Related applications

This page overlaps with:

- [Heat-treatment furnace atmosphere](https://www.sarveshanalytics.com/applications/heat-treatment-furnace-atmosphere.html)

## Sampling and installation

- Every ACCURRA-S has an internal fine filter and rotameter. Regulate sample pressure and flow externally; the catalogue recommends about 1 LPM and a sample pressure of 2 to 10 psig.
- Models 3015, M015, 3130 and 3190 are supplied without an internal sample pump. Tell us the sample pressure and we will confirm the sample path or add a pump.
- Models 3015 and M015 have no auto-calibration, so plan a calibration routine with the right reference gas.
- Keep sample lines short, clean and dry, and vent the sample somewhere safe.

ACCURRA-S sample specification: non-corrosive, non-toxic, non-flammable, non-condensing and dry, free from entrained oil; sample pressure 2 to 10 psig, regulated externally; flow about 1 LPM; dust below 3 micron. Where your sample differs, we design conditioning around it.

## Send us your process data

**What the data sheet asks for**

Send what you have and we will ask for the rest.

- The gases to measure, the range, and the accuracy you need
- Background gases and their typical composition
- Sample temperature, pressure and dew point at the tapping point
- Dust level, and whether the gas carries tar, oil or condensable vapour
- Process connection and, for ducts, the duct diameter
- Where the sample vents to, and at what pressure
- Area classification of the tapping point and of the analyser location, and the IP protection needed
- Distance between the tapping point and the analyser
- Outputs you need: 4-20 mA, dual range, relays, Modbus RTU
- Calibration approach, calibration gas available, and whether blowback is required
- Utilities at site: power supply, instrument air, nitrogen, steam and cooling water, and the ambient temperature range
- Gases and ranges: H2, dew point
- The point to confirm: Sampling after the furnace exit or muffle.

## Recommended Sarvesh products

[

### ACCURRA-S

Trace, percent and purity analysis of O2, CO, CO2, CH4 and dew point. View ACCURRA-S

](https://www.sarveshanalytics.com/safe-gas-analyser.html)[

### ACCURRA-TCD

Binary purity or percentage with no reference gas. View ACCURRA-TCD

](https://www.sarveshanalytics.com/binary-tcd-thermal-conductivity-analysers.html)

## Frequently asked questions

**Which analyser suits bright annealing of copper tube, stainless steel and wire?**

TCD (H2 in N2), M015 Hydrogen-nitrogen atmospheres and dew point set surface finish.

**What should I check before ordering for bright annealing of copper tube, stainless steel and wire?**

Sampling after the furnace exit or muffle.

**Who typically needs this?**

Typical buyers in India: copper tube makers, stainless strip and wire makers, bright-annealing furnace OEMs.

**Can Sarvesh support a variation of this application?**

Yes. If your process differs from the usual case, send the details. Application engineering is where we start every project, and bespoke applications are welcome.

## More in Steel, heat treatment and furnaces

- [Heat-treatment furnace atmosphere](https://www.sarveshanalytics.com/applications/heat-treatment-furnace-atmosphere.html)
- [Steel plant process gases](https://www.sarveshanalytics.com/applications/steel-plant-process-gas-analysis.html)
- [Float glass bath atmosphere](https://www.sarveshanalytics.com/applications/float-glass-bath-and-furnace-atmosphere.html)
- [Cold rolling mill furnaces](https://www.sarveshanalytics.com/applications/cold-rolling-mill-furnace-atmosphere.html)
- [Powder metallurgy and metal injection moulding sintering](https://www.sarveshanalytics.com/applications/powder-metallurgy-and-metal-injection-moulding-sintering.html)
- [Aluminium controlled-atmosphere brazing furnaces](https://www.sarveshanalytics.com/applications/aluminium-controlled-atmosphere-brazing-furnaces.html)
- [Carburising and endothermic gas carbon potential](https://www.sarveshanalytics.com/applications/carburising-and-endothermic-gas-carbon-potential.html)
- [Continuous annealing and galvanising line atmospheres (HNX)](https://www.sarveshanalytics.com/applications/continuous-annealing-and-galvanising-line-atmospheres-hnx.html)
- [Foundry cupola and melting furnace gas](https://www.sarveshanalytics.com/applications/foundry-cupola-and-melting-furnace-gas.html)
- [**All steel, heat treatment and furnaces applications**](https://www.sarveshanalytics.com/industries/steel-metals-heat-treatment-gas-analysers.html)
- [Browse analysers by gas](https://www.sarveshanalytics.com/gas-analyser.html)