# CO2 purity and trace oxygen analysis for dry ice and liquid CO2 plants

Beverage and dry-ice CO2 is sold on purity; trace oxygen is a typical limit. Sarvesh supplies ACCURRA-S 6030, 3015, built in Pune, with sampling matched to the stream.

- ISO 9001:2015, certified by TÜV
- Designed and built in Pune since 2002
- Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO

 Quick answer

Use ACCURRA-S 6030 (CO2 up to 100 %), 3015. Beverage and dry-ice CO2 is sold on purity; trace oxygen is a typical limit. Sample must be dry and free of oil; add conditioning for process streams.

Updated 2 November 2026 · Figures from Sarvesh datasheets

## The measurement and why it matters

Beverage and dry-ice CO2 is sold on purity; trace oxygen is a typical limit. This application matches the catalogue specification directly.

Industrial gas producers, distributors and users all buy and sell on a purity figure. A reading taken continuously, at the point where gas changes hands or enters a process, lets a plant release a batch with confidence instead of waiting for a laboratory result.

Most gas-handling streams are clean, dry and pressurised, which suits the ACCURRA-S sample specification. The points to settle are usually the sample path (vaporised, regulated and vented safely) and whether the stream is a binary mixture, which is the condition for ACCURRA-TCD.

Typical buyers in India: CO2 gas producers, dry-ice makers, beverage fillers. Where this matches your plant, send us the gas, range, pressure and temperature at the tapping point and we will confirm the analyser and sample path.

## Models and ranges

| Model | Measures | Range | Sensor and notes |
|---|---|---|---|
| 6030 | Carbon dioxide | 0 to 20 % or 0 to 100 % | NDIR |
| 3015 | Trace oxygen | 0 to 1000 ppm (min range 0 to 100 ppm) | Electrochemical; no internal pump, no auto-calibration |

## Process notes

### What the analyser reads here

Gases of interest: CO2, O2 ppm. Analyser fit: ACCURRA-S 6030 (CO2 up to 100 %), 3015.

The table above lists each model with its range; where a row says to confirm the range, we check it against the datasheet for your application before quoting.

### What to settle before ordering

Sample must be dry and free of oil; add conditioning for process streams.

We would rather confirm these points at the start than discover them at commissioning, so please include them with your process details.

## Sampling and installation

- Every ACCURRA-S has an internal fine filter and rotameter. Regulate sample pressure and flow externally; the catalogue recommends about 1 LPM and a sample pressure of 2 to 10 psig.
- Models 3015, M015, 3130 and 3190 are supplied without an internal sample pump. Tell us the sample pressure and we will confirm the sample path or add a pump.
- Models 3015 and M015 have no auto-calibration, so plan a calibration routine with the right reference gas.
- Keep sample lines short, clean and dry, and vent the sample somewhere safe.

ACCURRA-S sample specification: non-corrosive, non-toxic, non-flammable, non-condensing and dry, free from entrained oil; sample pressure 2 to 10 psig, regulated externally; flow about 1 LPM; dust below 3 micron. Where your sample differs, we design conditioning around it.

## Send us your process data

**What the data sheet asks for**

Send what you have and we will ask for the rest.

- The gases to measure, the range, and the accuracy you need
- Background gases and their typical composition
- Sample temperature, pressure and dew point at the tapping point
- Dust level, and whether the gas carries tar, oil or condensable vapour
- Process connection and, for ducts, the duct diameter
- Where the sample vents to, and at what pressure
- Area classification of the tapping point and of the analyser location, and the IP protection needed
- Distance between the tapping point and the analyser
- Outputs you need: 4-20 mA, dual range, relays, Modbus RTU
- Calibration approach, calibration gas available, and whether blowback is required
- Utilities at site: power supply, instrument air, nitrogen, steam and cooling water, and the ambient temperature range
- Gases and ranges: CO2, O2 ppm
- The point to confirm: Sample must be dry and free of oil; add conditioning for process streams.

## Recommended Sarvesh products

[

### ACCURRA-S

Trace, percent and purity analysis of O2, CO, CO2, CH4 and dew point. View ACCURRA-S

](https://www.sarveshanalytics.com/safe-gas-analyser.html)[

### SV-200 / SV-400 vaporisers

Vaporiser for cryogenic and wet samples. View SV-200 / SV-400 vaporisers

](https://www.sarveshanalytics.com/sample-vaporisers.html)

## Frequently asked questions

**Which analyser suits dry ice and liquid CO2 plant purity?**

ACCURRA-S 6030 (CO2 up to 100 %), 3015 Beverage and dry-ice CO2 is sold on purity; trace oxygen is a typical limit.

**What should I check before ordering for dry ice and liquid CO2 plant purity?**

Sample must be dry and free of oil; add conditioning for process streams.

**Who typically needs this?**

Typical buyers in India: CO2 gas producers, dry-ice makers, beverage fillers.

**Can Sarvesh support a variation of this application?**

Yes. If your process differs from the usual case, send the details. Application engineering is where we start every project, and bespoke applications are welcome.

## Further reading

- [Rotronic: monitoring compressed air systems](https://www.rotronic.com/rms/applications/monitoring-compressed-air-systems)

## More in Air separation and industrial gases

- [Oxygen purity in air separation plants](https://www.sarveshanalytics.com/applications/oxygen-purity-air-separation-plant.html)
- [Medical oxygen plant purity monitoring](https://www.sarveshanalytics.com/applications/medical-oxygen-plant-purity-monitoring.html)
- [Nitrogen purity and trace oxygen](https://www.sarveshanalytics.com/applications/nitrogen-purity-trace-oxygen.html)
- [Dew point and trace moisture in process gases](https://www.sarveshanalytics.com/applications/dew-point-and-trace-moisture-in-process-gases.html)
- [Gas purity certification and cylinder filling](https://www.sarveshanalytics.com/applications/gas-purity-certification-and-cylinder-filling.html)
- [Liquid oxygen, nitrogen and argon tanker and bulk-storage quality check](https://www.sarveshanalytics.com/applications/liquid-oxygen-nitrogen-and-argon-tanker-and-bulk-storage-quality-check.html)
- [Argon recovery and purification](https://www.sarveshanalytics.com/applications/argon-recovery-and-purification.html)
- [Helium purity and recovery](https://www.sarveshanalytics.com/applications/helium-purity-and-recovery.html)
- [Food-grade CO2 recovery from distilleries, breweries and fermentation](https://www.sarveshanalytics.com/applications/food-grade-co2-recovery-from-distilleries-breweries-and-fermentation.html)
- [Medical nitrous oxide purity](https://www.sarveshanalytics.com/applications/medical-nitrous-oxide-purity.html)
- [Compressed-air and instrument-air dew point (ISO 8573)](https://www.sarveshanalytics.com/applications/compressed-air-and-instrument-air-dew-point-iso-8573.html)
- [Medical-air and breathing-air quality](https://www.sarveshanalytics.com/applications/medical-air-and-breathing-air-quality.html)
- [Laser-cutting nitrogen and oxygen assist-gas purity](https://www.sarveshanalytics.com/applications/laser-cutting-nitrogen-and-oxygen-assist-gas-purity.html)
- [**All air separation and industrial gases applications**](https://www.sarveshanalytics.com/industries/industrial-gas-plant-gas-analysers.html)
- [Browse analysers by gas](https://www.sarveshanalytics.com/gas-analyser.html)