title: Glove Box Oxygen and Moisture Analyser
url: https://www.sarveshanalytics.com/applications/glove-boxes-and-isolators-o2-and-moisture.html
description: Glove box oxygen and moisture analyser with ACCURRA-S 3015, M015. Battery R&D, pharma and materials labs keep boxes below set oxygen and moisture limits.
updated: 2026-11-02
source: html
---

Electronics, cable and research

# Oxygen and moisture analysis for glove boxes and isolators

Battery R&D, pharma and materials labs keep boxes below set oxygen and moisture limits. Sarvesh supplies ACCURRA-S 3015, M015, built in Pune, with sampling matched to the stream.

- ISO 9001:2015, certified by TÜV
- Designed and built in Pune since 2002
- Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO

 Quick answer

Use ACCURRA-S 3015 + M015 (dual). Battery R&D, pharma and materials labs keep boxes below set oxygen and moisture limits. Sample drawn from a small closed volume must be returned or limited.

Updated 2 November 2026 · Figures from Sarvesh datasheets

## The measurement and why it matters

Battery R&D, pharma and materials labs keep boxes below set oxygen and moisture limits. This is a good fit, with one configuration or sample-handling point to confirm before we quote.

In furnaces, chambers and dry rooms the atmosphere is part of the recipe. A few ppm of oxygen, a dew point or a hydrogen share decides surface finish, yield or safety, and a leak or a drifting gas supply shows up in the analyser before it shows up in the product.

These atmospheres are usually clean at the analyser but can be hot, sooty or particulate-laden at the furnace take-off. Sample from the right point, keep lines short and use dry stainless tubing. Tell us the furnace or chamber volume and flow so we can confirm the sample path.

Typical buyers in India: battery and materials R&D labs, universities, pharma. Where this matches your plant, send us the gas, range, pressure and temperature at the tapping point and we will confirm the analyser and sample path.

## Models and ranges

| Model | Measures | Range | Sensor and notes |
|---|---|---|---|
| 3015 | Trace oxygen | 0 to 1000 ppm (min range 0 to 100 ppm) | Electrochemical; no internal pump, no auto-calibration |
| M015 | Dew point | -80 to +20 C | Ceramic sensor; no internal pump, no auto-calibration |

## Process notes

### What the analyser reads here

Gases of interest: O2 ppm, dew point. Analyser fit: ACCURRA-S 3015 + M015 (dual).

The table above lists each model with its range; where a row says to confirm the range, we check it against the datasheet for your application before quoting.

### What to settle before ordering

Sample drawn from a small closed volume must be returned or limited.

We would rather confirm these points at the start than discover them at commissioning, so please include them with your process details.

## Sampling and installation

- Every ACCURRA-S has an internal fine filter and rotameter. Regulate sample pressure and flow externally; the catalogue recommends about 1 LPM and a sample pressure of 2 to 10 psig.
- Models 3015, M015, 3130 and 3190 are supplied without an internal sample pump. Tell us the sample pressure and we will confirm the sample path or add a pump.
- Models 3015 and M015 have no auto-calibration, so plan a calibration routine with the right reference gas.
- Keep sample lines short, clean and dry, and vent the sample somewhere safe.

ACCURRA-S sample specification: non-corrosive, non-toxic, non-flammable, non-condensing and dry, free from entrained oil; sample pressure 2 to 10 psig, regulated externally; flow about 1 LPM; dust below 3 micron. Where your sample differs, we design conditioning around it.

## Send us your process data

**What the data sheet asks for**

Send what you have and we will ask for the rest.

- The gases to measure, the range, and the accuracy you need
- Background gases and their typical composition
- Sample temperature, pressure and dew point at the tapping point
- Dust level, and whether the gas carries tar, oil or condensable vapour
- Process connection and, for ducts, the duct diameter
- Where the sample vents to, and at what pressure
- Area classification of the tapping point and of the analyser location, and the IP protection needed
- Distance between the tapping point and the analyser
- Outputs you need: 4-20 mA, dual range, relays, Modbus RTU
- Calibration approach, calibration gas available, and whether blowback is required
- Utilities at site: power supply, instrument air, nitrogen, steam and cooling water, and the ambient temperature range
- Gases and ranges: O2 ppm, dew point
- The point to confirm: Sample drawn from a small closed volume must be returned or limited.

## Recommended Sarvesh products

[

### ACCURRA-S

Trace, percent and purity analysis of O2, CO, CO2, CH4 and dew point. View ACCURRA-S

](https://www.sarveshanalytics.com/safe-gas-analyser.html)

## Frequently asked questions

**Which analyser suits glove boxes and isolators (O2 and moisture)?**

ACCURRA-S 3015 + M015 (dual) Battery R&D, pharma and materials labs keep boxes below set oxygen and moisture limits.

**What should I check before ordering for glove boxes and isolators (O2 and moisture)?**

Sample drawn from a small closed volume must be returned or limited.

**Who typically needs this?**

Typical buyers in India: battery and materials R&D labs, universities, pharma.

**Can Sarvesh support a variation of this application?**

Yes. If your process differs from the usual case, send the details. Application engineering is where we start every project, and bespoke applications are welcome.

## More in Electronics, cable and research

- [Semiconductor and electronics gas purity](https://www.sarveshanalytics.com/applications/semiconductor-and-electronics-gas-purity.html)
- [Optical fibre and cable manufacturing](https://www.sarveshanalytics.com/applications/optical-fibre-and-cable-manufacturing.html)
- [Welding and laser gas mixtures](https://www.sarveshanalytics.com/applications/welding-and-laser-gas-mixtures.html)
- [Aerospace, nuclear and research laboratories](https://www.sarveshanalytics.com/applications/aerospace-nuclear-and-research-labs.html)
- [Metal additive manufacturing build-chamber oxygen](https://www.sarveshanalytics.com/applications/metal-additive-manufacturing-build-chamber-oxygen.html)
- [Lithium-ion battery dry rooms and electrode drying](https://www.sarveshanalytics.com/applications/lithium-ion-battery-dry-rooms-and-electrode-drying.html)
- [Research furnaces and CVD/ALD labs](https://www.sarveshanalytics.com/applications/research-furnaces-and-cvd-ald-labs.html)
- [Reactor cover-gas and glove-box atmospheres (O2 and moisture in argon)](https://www.sarveshanalytics.com/applications/reactor-cover-gas-and-glove-box-atmospheres-o2-and-moisture-in-argon.html)
- [**All electronics, cable and research applications**](https://www.sarveshanalytics.com/industries/electronics-cable-research-gas-analysers.html)
- [Browse analysers by gas](https://www.sarveshanalytics.com/gas-analyser.html)