# Hydrogen purity and purge gas analysers for hydrogen-cooled generators

Large turbo-generators in thermal power stations are cooled by hydrogen. Its purity sets how well the machine is cooled and how much power is lost to windage, and every fill and degassing passes through CO2 so that hydrogen and air never meet in the casing. ACCURRA-TCD measures hydrogen in air and hydrogen in CO2 by thermal conductivity, with no reference gas.

 Quick answer

Sarvesh supplies ACCURRA-TCD thermal conductivity analysers for hydrogen-cooled generators: [hydrogen purity](https://www.sarveshanalytics.com/hydrogen-gas-analyser.html) in service and hydrogen in CO2 during purging, with no reference gas. ACCURRA-S 6030 reads CO2 in air during the purge, M015 reads the dew point of the hydrogen, and ACCURRA-Hz covers analysers that must stand in a hazardous area.

Figures from Sarvesh datasheets

## The measurement and why it matters

Hydrogen carries heat away roughly seven times better than air and is about a fourteenth of its density. Both properties matter inside a generator: the rotor and stator windings are cooled better, and the gas drags far less on the spinning rotor, so windage losses fall. As air leaks into the casing the mixture becomes denser and conducts heat less well. Losses rise and cooling margins shrink, which is why operators watch hydrogen purity continuously while the machine runs and top up or purge when it falls.

Hydrogen burns in air over a wide range of concentrations, roughly 4 to 75 percent by volume. A generator is therefore never switched straight from air to hydrogen or back. Carbon dioxide is used as an intermediate purge gas: it first displaces the air, then hydrogen displaces the CO2. Degassing for maintenance runs the same steps in reverse. At each step the operator needs to know when the displacement is complete before moving on.

Each of those steps is a two-gas mixture: CO2 in air while CO2 pushes the air out, hydrogen in CO2 while hydrogen fills the casing, and hydrogen in air when the machine is in service. Two-gas mixtures with a large difference in thermal conductivity are what a [thermal conductivity analyser](https://www.sarveshanalytics.com/binary-tcd-thermal-conductivity-analysers.html) measures best. Hydrogen against air and hydrogen against CO2 both have a wide conductivity gap, so the signal is strong and the full range is usable.

ACCURRA-TCD measures hydrogen over 0 to 100 percent against one known background gas, chosen from air, nitrogen, carbon dioxide, methane, argon, helium or oxygen. It works with one background at a time, so each purge step needs a measurement set up for its own pair of gases. We agree the arrangement at the application review: for example, a hydrogen purity analyser for service and a second measurement for the purge, with ACCURRA-S 6030 reading CO2 directly while CO2 displaces the air.

## Models and ranges

| Model | Measures | Range | Sensor and notes |
|---|---|---|---|
| ACCURRA-TCD | Hydrogen purity in service (hydrogen in air) | 0 to 100 %, range set for the duty | Platinum thermal conductivity, no reference gas |
| ACCURRA-TCD | Hydrogen in CO2 during filling and degassing | Binary mixture | Calibrated for the CO2 background |
| 6030 | CO2 in air while CO2 displaces air | 0 to 20 % or 0 to 100 % (min range 0 to 5 %) | ACCURRA-S, NDIR |
| M015 | Dew point of the generator hydrogen | -80 to +20 °C dew point | ACCURRA-S, ceramic sensor |
| ACCURRA-Hz TCD housing | Hydrogen, hazardous area | Percent or purity, application specific | Gas Group IIC, Zone 1 and 2, T6 |

## Process notes

### In service: hydrogen purity

In service the analyser reads hydrogen purity from a sampling point on the generator gas system, continuously. ACCURRA-TCD has programmable alarms (Lo-Hi, Lo-Lo and Hi-Hi), dual and suppressed 4–20 mA ranges and Modbus RTU, so a low-purity alarm can go to the control room and the purity trend to the DCS.

Repeatability and linearity are below 1 percent, errors and drift below 1 percent of full scale per week, and T90 is below 10 seconds at 0.6 LPM. Because there is no reference gas, there is no extra cylinder to keep on the gas panel. A range set close to the operating purity gives the best resolution where the operator looks most.

### Filling and degassing: the CO2 purge

During filling, CO2 first displaces the air. A CO2 reading in air, from ACCURRA-S 6030, shows when the casing holds enough CO2 for hydrogen to be admitted. Hydrogen then displaces the CO2, and a hydrogen-in-CO2 reading shows when the purge is complete and the purity is high enough to put the machine into service.

Degassing reverses the order: CO2 displaces the hydrogen, then air displaces the CO2 before anyone opens the casing. The end points of each step are set in your operating procedure; the analyser shows when they are reached. Tell us which steps you want to measure and we will propose the analysers and the sample switching.

### Moisture in the hydrogen

Generator hydrogen is kept dry by a gas dryer. A rising dew point points to a dryer that needs attention or to water entering the gas system, so many stations read dew point alongside purity. ACCURRA-S M015 reads dew point from -80 to +20 °C, and a hazardous-area moisture analyser is available where the sample point is in a classified zone.

### Safe area or hazardous area

ACCURRA-TCD is a safe-area instrument for a 19 inch rack or panel. If the analyser has to stand in a classified area near the hydrogen gas panel, ACCURRA-Hz houses hydrogen measurement by thermal conductivity and is certified for Gas Group IIC, Zone 1 and 2, T6. Send us the area classification of the analyser location with your enquiry.

## Sampling and installation

- Provide about 0.6 LPM of sample at a regulated 2 to 10 psig. The sample should reach ACCURRA-TCD at 5 to 45 °C, with its dew point at least 5 °C below the lowest ambient.
- Gas from the generator can carry seal-oil mist. Fit a Headline [coalescing filter](https://www.sarveshanalytics.com/headline-filters/coalescing-filters.html) upstream of the analyser to keep liquid and particulates off the sensor.
- Vent the analyser outlet to a safe place, in the same way as the rest of the hydrogen system.
- The reading assumes a two-gas mixture. Tell us if any other gas can be present, for example nitrogen used for purging.

ACCURRA-S sample specification: non-corrosive, non-toxic, non-flammable, non-condensing and dry, free from entrained oil; sample pressure 2 to 10 psig, regulated externally; flow about 1 LPM; dust below 3 micron. Where your sample differs, we design conditioning around it.

## Send us your process data

### What matters most for this application

- Which steps you want to measure: purity in service, the CO2 purge, or both
- The area classification where the analyser will stand
- Sample pressure and temperature at the tapping point
- The signals you need: 4–20 mA, alarms or Modbus RTU

## Recommended Sarvesh products

[

### ACCURRA-TCD

Hydrogen purity, and hydrogen in CO2 during the purge. View ACCURRA-TCD

](https://www.sarveshanalytics.com/binary-tcd-thermal-conductivity-analysers.html)[

### ACCURRA-Hz

Hydrogen measurement where the analyser stands in a hazardous area. View ACCURRA-Hz

](https://www.sarveshanalytics.com/hazardous-gas-analysers.html)[

### ACCURRA-S

CO2 in air during the purge, and dew point of the hydrogen. View ACCURRA-S

](https://www.sarveshanalytics.com/safe-gas-analyser.html)[

###

Coalescing filters ahead of the sensor. View the Headline range

](https://www.sarveshanalytics.com/headline-filters.html)[

### Engineered analyser panels

Analyser panels with sample conditioning and switching. View Engineered analyser panels

](https://www.sarveshanalytics.com/analyser-sampling-panels.html)

## Ask for a price

Leave your details and an applications engineer in Pune, India, replies with questions or a proposal.

## Frequently asked questions

**Does the generator hydrogen analyser need a reference gas?**

No. ACCURRA-TCD uses a platinum thermal conductivity sensor and needs no reference gas.

**Can one analyser cover hydrogen purity and both purge steps?**

ACCURRA-TCD measures hydrogen against one background gas at a time. Tell us which steps you want to watch and we will propose the arrangement, for example a purity analyser for service and a separate measurement for the purge.

**How fast does the hydrogen reading respond?**

T90 is below 10 seconds at a sample flow of 0.6 LPM.

**Can the analyser be installed in a hazardous area?**

ACCURRA-TCD is a safe-area instrument. For a classified area, ACCURRA-Hz is certified for Gas Group IIC, Zone 1 and 2, T6.

**Do you also measure the dew point of generator hydrogen?**

Yes. ACCURRA-S M015 reads dew point from -80 to +20 °C, and a hazardous-area moisture analyser is available.

## More in Power, boilers and emissions

- [Boiler and furnace oxygen (flue gas)](https://www.sarveshanalytics.com/applications/boiler-and-furnace-oxygen-flue-gas.html)
- [Stack and emission monitoring](https://www.sarveshanalytics.com/applications/stack-and-emission-monitoring-system.html)
- [Thermal oxidiser and scrubber efficiency](https://www.sarveshanalytics.com/applications/thermal-oxidiser-and-scrubber-monitoring.html)
- [Cement kiln and precalciner O2 and CO](https://www.sarveshanalytics.com/applications/cement-kiln-and-precalciner-o2-and-co.html)
- [Coal mill inerting and fire protection](https://www.sarveshanalytics.com/applications/coal-mill-inerting-and-fire-protection.html)
- [Waste-heat recovery boilers and kiln WHRS](https://www.sarveshanalytics.com/applications/waste-heat-recovery-boilers-and-kiln-whrs.html)
- [Biomass, bagasse and rice-husk boiler combustion trim](https://www.sarveshanalytics.com/applications/biomass-bagasse-and-rice-husk-boiler-combustion-trim.html)
- [Thermic-fluid heaters and hot-air generators](https://www.sarveshanalytics.com/applications/thermic-fluid-heaters-and-hot-air-generators.html)
- [Glass melting furnace combustion trim](https://www.sarveshanalytics.com/applications/glass-melting-furnace-combustion-trim.html)
- [Boiler and burner factory test benches](https://www.sarveshanalytics.com/applications/boiler-and-burner-factory-test-benches.html)
- [**All power, boilers and emissions applications**](https://www.sarveshanalytics.com/industries/power-plant-emission-monitoring-gas-analysers.html)
- [Browse analysers by gas](https://www.sarveshanalytics.com/gas-analyser.html)