---
title: LOX, Nitrogen and Argon Tanker Quality Check
url: https://www.sarveshanalytics.com/applications/liquid-oxygen-nitrogen-and-argon-tanker-and-bulk-storage-quality-check.html
description: Bulk oxygen, nitrogen and argon quality check with ACCURRA-S 3090, 3190, 3015. Purity at delivery and at the storage tank decides acceptance. Made in Pune.
updated: 2026-11-02
source: html
---

Air separation and industrial gases

# Quality check for liquid oxygen, nitrogen and argon tankers and bulk storage

Purity at delivery and at the storage tank decides acceptance. Compensated purity models avoid weather-driven false rejects. Sarvesh supplies ACCURRA-S 3090, 3190, 3015, built in Pune, with sampling matched to the stream.

- ISO 9001:2015, certified by TÜV
- Designed and built in Pune since 2002
- Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO

 Quick answer

Use ACCURRA-S 3090/3190 (O2 purity), 3015 (trace O2 in N2/Ar). Purity at delivery and at the storage tank decides acceptance. Compensated purity models avoid weather-driven false rejects. Sample taken from a vaporised, pressurised line; confirm the sample path.

Updated 2 November 2026 · Figures from Sarvesh datasheets

## The measurement and why it matters

Purity at delivery and at the storage tank decides acceptance. Compensated purity models avoid weather-driven false rejects. This application matches the catalogue specification directly.

Industrial gas producers, distributors and users all buy and sell on a purity figure. A reading taken continuously, at the point where gas changes hands or enters a process, lets a plant release a batch with confidence instead of waiting for a laboratory result.

Most gas-handling streams are clean, dry and pressurised, which suits the ACCURRA-S sample specification. The points to settle are usually the sample path (vaporised, regulated and vented safely) and whether the stream is a binary mixture, which is the condition for ACCURRA-TCD.

Typical buyers in India: industrial gas producers, bulk users, hospitals with LOX tanks. Where this matches your plant, send us the gas, range, pressure and temperature at the tapping point and we will confirm the analyser and sample path.

## Models and ranges

| Model | Measures | Range | Sensor and notes |
|---|---|---|---|
| 3090 | Oxygen purity | 0 to 100 %, compensated | Electrochemical, ambient pressure and temperature compensated |
| 3190 | Oxygen purity | 95 to 100 % | Paramagnetic sensor, compensated; no internal pump |
| 3015 | Trace oxygen | 0 to 1000 ppm (min range 0 to 100 ppm) | Electrochemical; no internal pump, no auto-calibration |

## Process notes

### What the analyser reads here

Gases of interest: O2, N2, Ar. Analyser fit: ACCURRA-S 3090/3190 (O2 purity), 3015 (trace O2 in N2/Ar).

The table above lists each model with its range; where a row says to confirm the range, we check it against the datasheet for your application before quoting.

### What to settle before ordering

Sample taken from a vaporised, pressurised line; confirm the sample path.

We would rather confirm these points at the start than discover them at commissioning, so please include them with your process details.

## Related applications

This page overlaps with:

- [Oxygen purity in air separation plants](https://www.sarveshanalytics.com/applications/oxygen-purity-air-separation-plant.html)

## Sampling and installation

- Every ACCURRA-S has an internal fine filter and rotameter. Regulate sample pressure and flow externally; the catalogue recommends about 1 LPM and a sample pressure of 2 to 10 psig.
- Models 3015, M015, 3130 and 3190 are supplied without an internal sample pump. Tell us the sample pressure and we will confirm the sample path or add a pump.
- Models 3015 and M015 have no auto-calibration, so plan a calibration routine with the right reference gas.
- Keep sample lines short, clean and dry, and vent the sample somewhere safe.

ACCURRA-S sample specification: non-corrosive, non-toxic, non-flammable, non-condensing and dry, free from entrained oil; sample pressure 2 to 10 psig, regulated externally; flow about 1 LPM; dust below 3 micron. Where your sample differs, we design conditioning around it.

## Send us your process data

**What the data sheet asks for**

Send what you have and we will ask for the rest.

- The gases to measure, the range, and the accuracy you need
- Background gases and their typical composition
- Sample temperature, pressure and dew point at the tapping point
- Dust level, and whether the gas carries tar, oil or condensable vapour
- Process connection and, for ducts, the duct diameter
- Where the sample vents to, and at what pressure
- Area classification of the tapping point and of the analyser location, and the IP protection needed
- Distance between the tapping point and the analyser
- Outputs you need: 4-20 mA, dual range, relays, Modbus RTU
- Calibration approach, calibration gas available, and whether blowback is required
- Utilities at site: power supply, instrument air, nitrogen, steam and cooling water, and the ambient temperature range
- Gases and ranges: O2, N2, Ar
- The point to confirm: Sample taken from a vaporised, pressurised line; confirm the sample path.

## Recommended Sarvesh products

[

### ACCURRA-S 3090

Compensated oxygen purity, 95 to 100 %. View ACCURRA-S 3090

](https://www.sarveshanalytics.com/oxygen-gas-analyser.html)[

### ACCURRA-S

Trace, percent and purity analysis of O2, CO, CO2, CH4 and dew point. View ACCURRA-S

](https://www.sarveshanalytics.com/safe-gas-analyser.html)[

### SV-200 / SV-400 vaporisers

Vaporiser for cryogenic and wet samples. View SV-200 / SV-400 vaporisers

](https://www.sarveshanalytics.com/sample-vaporisers.html)

## Frequently asked questions

**Which analyser suits liquid oxygen, nitrogen and argon tanker and bulk-storage quality check?**

ACCURRA-S 3090/3190 (O2 purity), 3015 (trace O2 in N2/Ar) Purity at delivery and at the storage tank decides acceptance. Compensated purity models avoid weather-driven false rejects.

**What should I check before ordering for liquid oxygen, nitrogen and argon tanker and bulk-storage quality check?**

Sample taken from a vaporised, pressurised line; confirm the sample path.

**Who typically needs this?**

Typical buyers in India: industrial gas producers, bulk users, hospitals with LOX tanks.

**Can Sarvesh support a variation of this application?**

Yes. If your process differs from the usual case, send the details. Application engineering is where we start every project, and bespoke applications are welcome.

## More in Air separation and industrial gases

- [Oxygen purity in air separation plants](https://www.sarveshanalytics.com/applications/oxygen-purity-air-separation-plant.html)
- [Medical oxygen plant purity monitoring](https://www.sarveshanalytics.com/applications/medical-oxygen-plant-purity-monitoring.html)
- [Nitrogen purity and trace oxygen](https://www.sarveshanalytics.com/applications/nitrogen-purity-trace-oxygen.html)
- [Dew point and trace moisture in process gases](https://www.sarveshanalytics.com/applications/dew-point-and-trace-moisture-in-process-gases.html)
- [Gas purity certification and cylinder filling](https://www.sarveshanalytics.com/applications/gas-purity-certification-and-cylinder-filling.html)
- [Argon recovery and purification](https://www.sarveshanalytics.com/applications/argon-recovery-and-purification.html)
- [Helium purity and recovery](https://www.sarveshanalytics.com/applications/helium-purity-and-recovery.html)
- [Dry ice and liquid CO2 plant purity](https://www.sarveshanalytics.com/applications/dry-ice-and-liquid-co2-plant-purity.html)
- [Food-grade CO2 recovery from distilleries, breweries and fermentation](https://www.sarveshanalytics.com/applications/food-grade-co2-recovery-from-distilleries-breweries-and-fermentation.html)
- [Medical nitrous oxide purity](https://www.sarveshanalytics.com/applications/medical-nitrous-oxide-purity.html)
- [Compressed-air and instrument-air dew point (ISO 8573)](https://www.sarveshanalytics.com/applications/compressed-air-and-instrument-air-dew-point-iso-8573.html)
- [Medical-air and breathing-air quality](https://www.sarveshanalytics.com/applications/medical-air-and-breathing-air-quality.html)
- [Laser-cutting nitrogen and oxygen assist-gas purity](https://www.sarveshanalytics.com/applications/laser-cutting-nitrogen-and-oxygen-assist-gas-purity.html)
- [**All air separation and industrial gases applications**](https://www.sarveshanalytics.com/industries/industrial-gas-plant-gas-analysers.html)
- [Browse analysers by gas](https://www.sarveshanalytics.com/gas-analyser.html)
