---
title: Dew Point Meters, Transmitters and Analysers | Sarvesh
url: https://www.sarveshanalytics.com/dew-point-meters-and-transmitters.html
description: Dew point meters, transmitters and online dew point analysers for compressed air, nitrogen, generator hydrogen and transformer drying. Made in Pune, India.
updated: 2026-11-23
source: html
---

Moisture and dew point

# Dew point meters, transmitters and online analysers

A spot check, a fixed point or a continuous product reading: the right dew point instrument depends on the question the number answers. We supply all three, and the sampling that makes them read true.

 Quick answer

Use a portable dew point meter or kit for spot checks, a fixed transmitter for one continuous point into a PLC, and an online analyser such as ACCURRA-S M015, which reads -80 to +20 °C dew point, where the product reading needs a display, alarms, Modbus and records. State whether the dew point is at line pressure or at atmosphere.

## Three kinds of dew point instrument

| Instrument | Fits | Watch |
|---|---|---|
| Portable meter or kit | Spot checks, dryer audits, commissioning, transformer drying, several points with one instrument | Readings are only as good as the time allowed for the sensor to dry down at each point |
| Fixed transmitter | Continuous reading at one point, such as a dryer outlet, into a PLC or DCS by 4–20 mA | Needs a sampling block or cell with a small purge, not a dead leg |
| Online analyser (ACCURRA-S M015) | Continuous, displayed and alarmed reading on product gas, with relays, Modbus and records | Sample is drawn to the analyser, so the sample path decides the response |

## The online analyser: ACCURRA-S M015

ACCURRA-S M015 reads dew point from -80 to +20 °C dp with a ceramic sensor, accuracy +/- 2 °C dp and repeatability 1 °C dp. Response is 2 min at 5 LPM, dry to wet. A sensor bypass valve is supplied, and the sensor cannot be calibrated in the field. M015 also runs beside the trace oxygen model 3015 in one enclosure, a common pair on nitrogen and argon: see the [trace oxygen and moisture analyser](https://www.sarveshanalytics.com/trace-oxygen-and-moisture-analyser.html). See the [M015 model page](https://www.sarveshanalytics.com/models/accurra-s-m015-dew-point-analyser.html) and the [dew point analyser](https://www.sarveshanalytics.com/trace-moisture-analyser.html) page; for a classified area, the [hazardous area moisture analyser](https://www.sarveshanalytics.com/hazardous-moisture-analyser.html).

## Portable kits and transmitter sampling systems

We build battery-powered portable dew point kits for spot checks and [sampling systems](https://www.sarveshanalytics.com/sampling-components.html) for fixed dew point transmitters, so the sensor sees a flowing sample at a known pressure rather than a dead leg. Tell us the gas, the expected dew point and the line pressure, and ask for the current specification.

## Where dew point is measured

- **Compressed and instrument air:** after the dryer, against the air quality class the plant needs. See [compressed air dew point and ISO 8573](https://www.sarveshanalytics.com/applications/compressed-air-and-instrument-air-dew-point-iso-8573.html).
- **Nitrogen, argon and process gases:** product moisture at ppm level. See [trace moisture in process gases](https://www.sarveshanalytics.com/applications/dew-point-and-trace-moisture-in-process-gases.html).
- **Hydrogen-cooled generators:** a rising dew point in the generator hydrogen points to the gas dryer or a water leak. See [generator hydrogen purity and purge](https://www.sarveshanalytics.com/applications/hydrogen-cooled-generator-purity-and-purge-monitoring.html).
- **Transformer drying and nitrogen filling:** after drying, transformer makers and utilities read the dew point of the dry gas in the tank once it has stood, and judge the dryness of the insulation from it and the insulation temperature. The acceptance value comes from the transformer maker's or the utility's procedure. A portable kit suits this job.
- **Battery dry rooms, glove boxes and furnace atmospheres:** see [battery dry rooms](https://www.sarveshanalytics.com/applications/lithium-ion-battery-dry-rooms-and-electrode-drying.html), [glove boxes](https://www.sarveshanalytics.com/applications/glove-boxes-and-isolators-o2-and-moisture.html) and [furnace atmospheres](https://www.sarveshanalytics.com/applications/heat-treatment-furnace-atmosphere.html).

## Getting a true reading

- **Pressure:** state whether a dew point is at line pressure or at atmosphere. Convert with the [dew point to ppm calculator](https://www.sarveshanalytics.com/calculators/dew-point-to-ppm-calculator.html).
- **Dry-down time:** a sensor exposed to room air needs time to come down to a dry gas. Wait for a stable reading before a test or a certificate.
- **Sample lines:** use short stainless steel lines; plastic tubing lets moisture in and gives it back slowly. See [moisture measurement methods compared](https://www.sarveshanalytics.com/learn/moisture-measurement-methods-compared.html).

## Ask for a price

Leave your details and an applications engineer in Pune, India, replies with questions or a proposal.

## Frequently asked questions

**What is the difference between a dew point meter and a dew point analyser?**

Both read the dew point of a gas. A meter is usually portable, for spot checks; a transmitter is fixed at one point; an analyser such as ACCURRA-S M015 draws a sample continuously and adds a display, alarms, Modbus and records.

**What range does ACCURRA-S M015 read?**

Dew point from -80 to +20 °C dp (minimum range -80 to 0 °C dp), with +/- 2 °C dp accuracy.

**Can the M015 be calibrated on site?**

No. Field calibration is not possible on M015; ask at the order how its calibration will be handled.

**Is pressure dew point the same as atmospheric dew point?**

No. Compressed gas has a higher dew point at line pressure than the same gas expanded to atmosphere. Use the dew point to ppm calculator to convert between them.

**Do you supply portable dew point kits?**

Yes. We build battery-powered portable dew point kits and sampling systems for dew point transmitters. Ask for the current specification for your gas and range.
