title: Activated Carbon Cartridges for Compressed Air | Headline
url: https://www.sarveshanalytics.com/headline-filters/activated-carbon-cartridges-for-compressed-air.html
description: Remove oil vapour and odour from compressed air with Headline CC carbon cloth cartridges: what they adsorb, prefilter pairs, sizes and codes. Sarvesh, India.
updated: 2026-11-23
source: html
---

Headline Filters · Compressed air

# Activated carbon cartridges for compressed air

Headline's grade CC cartridges remove the last traces of oil vapour and odour from compressed air. Each is a cylinder of activated carbon cloth between two filter tubes, and fits standard Headline housings at any line pressure. Headline rates carbon cloth up to 20 times more efficient than granular carbon for organic vapours.

 Quick answer

Headline's grade CC cartridges remove the last oil vapour and odour from compressed air with activated carbon cloth, which Headline rates up to 20 times more efficient than granular carbon. Fit one after a grade 50C coalescer. It adsorbs oil vapour, solvents and C4 and heavier hydrocarbons, but little methane, CO, CO2 or ammonia.

Figures from the Headline Filters catalogue and brochures

## What activated carbon removes

### Adsorbs well

- Hydrocarbons C4 and larger
- Freons
- Oil vapour
- Alcohols
- Aldehydes and ketones
- Aromatic hydrocarbons

### Adsorbs little

- Methane
- Carbon monoxide
- Carbon dioxide
- Acetylene
- Ammonia
- Amines
- Hydrocarbons C3 and lower

## Recommended prefilter and adsorber pairs

| Line size | Maximum flow at 7 bar, Nm³/h | Prefilter housing (grade 50C) | Adsorber housing and cartridge |
|---|---|---|---|
| 1/4" | 10 | 315, 315A | 315, 315A with 12-32-CC |
| 1/2" | 29 | 360F, 360AF | 360, 360A with 25-64-CC |
| 1/2" | 76 | 370F, 370AF | 370A with 25-178-CC |
| 3/4", 1" | 154 | 380AF | 380A with 38-152-CC |
| 1 1/2" | 241 | 385AF | 385 with 51-230-CC |
| 2" | 482 | 390AF | 390A with 51-476-CC |
| 3" | 1089 | 395AF | 395A with 63-762-CC |

## Cartridge sizes

**Outside diameter A, mmLength B, mmBore C, mmAdsorbent volume, ccMaximum temperature, °C**

| Specification | 12-32 | 12-57 | 25-64 | 25-178 | 51-230 | 51-476 |
|---|---|---|---|---|---|---|
|  | 24 | 24 | 40 | 40 | 65.5 | 65.5 |
|  | 32 | 57 | 64 | 178 | 230 | 476 |
|  | 12.5 | 12.5 | 26 | 26 | 52 | 52 |
|  | 6 | 9 | 20 | 90 | 175 | 415 |
|  | 50 | 50 | 50 | 50 | 50 | 50 |

**To order:** size, then adsorbent code, then the fitting suffix. Adsorbents: Activated carbon (CC), Molecular sieve 4A (4A), Molecular sieve 13X (13X), Silica gel (SG), Mixed bases (MB), Potassium permanganate (PP). Add TP for 700 series plastic and 300 series aluminium housings (for example 12-32-CCTP or 25-178-CCTP), or TS for 110 and 120 series stainless steel housings (for example 12-57-SGTS).

Flow is the same as a grade 50 element in the same housing, but adsorbent volume and contact time decide how well it works. Cartridges are rated to 50 °C.

Other gases and vapours, for example water vapour, CO2 or acid gases, need a different adsorbent: see [vapour removal adsorbers](https://www.sarveshanalytics.com/headline-filters/applications/vapour-removal-adsorbers.html).

## Frequently asked questions

**Why does oil vapour get past a coalescing filter?**

A coalescer removes oil and water as liquid aerosols. A small fraction of oil is present as a true vapour, which only an adsorbent such as activated carbon removes.

**Does the CC cartridge need a prefilter?**

Yes. Headline specifies a grade 50C coalescing prefilter ahead of every CC cartridge, so liquid oil never reaches the carbon.

**How long does a cartridge last?**

It depends on the vapour concentration, the flow and the contact time. Size by adsorbent volume, not flow, and tell us the duty for an estimate.

**Which cartridge suffix do I need?**

TP for 700 series plastic and 300 series aluminium housings, TS for 110 and 120 series stainless steel housings, for example 25-64-CCTP or 12-57-SGTS.

**Can I buy them in India?**

Sarvesh Analytics in Pune, India, is the exclusive representative of Headline Filters for the Indian subcontinent. Ask us for price and availability.