title: Flue Gas Analyser Filters and Elements | Headline, India
url: https://www.sarveshanalytics.com/headline-filters/applications/flue-gas-analyser-filters.html
description: Replacement filters for handheld flue gas and combustion analysers: glass fibre elements, disposable in-line filters and adsorbers. Sarvesh, Pune, India.
updated: 2026-11-23
source: html
---

Headline Filters · Application note

# Filters for handheld flue gas analysers

A handheld combustion analyser pulls hot, wet flue gas through a small pump and a probe hose, so its filters clog and its water trap fills on every job. Headline makes replacement glass fibre elements, disposable in-line filters and in-line adsorbers for these instruments, and Sarvesh Analytics supplies them from Pune, India.

 Quick answer

Headline's range of flue gas analyser filters and elements runs to 16 products in these families: filter elements and disposable in-line filters and adsorbers.

Figures from the Headline Filters catalogue and brochures

## What wears out

- **The particulate element.** Soot and ash from the flue collect on the element in the water trap or probe handle. A blocked element shows up as low flow or a pump fault on the analyser.
- **The in-line filter.** A disposable in-line filter in the sample hose protects the pump and sensors from fine dust that passes the first element.
- **The adsorber.** Disposable in-line adsorbers (DIA) remove a vapour that would upset a sensor, for example with activated carbon or silica gel.

## Matching the element to your analyser

- Headline lists several elements by the part number of the analyser filter they replace, for example the 10-37-60K element against Kane PF400/5. Send us the part number printed on your old filter and we confirm the Headline equivalent.
- Elements come with an epoxy binder for general use, a PVDF binder for corrosive samples and a silica binder for temperatures up to 500 °C. Use the silica version only where the sample is that hot.

## Headline products for this duty

Headline lists these 16 products for this application, grouped by family. Open a family to see every model; each links to its card with ports and rating.

**

### Filter elements 8 products**

[10-37-60K](https://www.sarveshanalytics.com/headline-filters/products/particulate-glass-fibre-filter-element-pvdf-corrosive-applications-copy.html)[12-32.7-70](https://www.sarveshanalytics.com/headline-filters/products/glass-fibre-filter-element-12-32-7-70-box-of-10.html)[12-43.5-60K](https://www.sarveshanalytics.com/headline-filters/products/glass-fibre-filter-element-12-43-5-60k.html)[Coalescing Glass Fibre Filter Element (PVDF - Corrosive Applications)](https://www.sarveshanalytics.com/headline-filters/products/box-of-10-coalescing-glass-fibre-filter-element-pvdf-corrosive-applications.html)[Coalescing Glass Fibre Filter Element (Silica - Up to 500°C)](https://www.sarveshanalytics.com/headline-filters/products/box-of-10-coalescing-glass-fibre-filter-element-silica-up-to-500-c-1.html)[Particulate Glass Fibre Filter Element (Epoxy - Standard)](https://www.sarveshanalytics.com/headline-filters/products/box-of-10-particulate-glass-fibre-filter-element-epoxy-standard.html)[Particulate Glass Fibre Filter Element (PVDF - Corrosive Applications)](https://www.sarveshanalytics.com/headline-filters/products/box-of-10-particulate-glass-fibre-filter-element-pvdf-corrosive-applications.html)[Particulate Glass Fibre Filter Element (Silica - up to 500°C)](https://www.sarveshanalytics.com/headline-filters/products/box-of-10-particulate-glass-fibre-filter-element-high-temp-up-to-500c.html)

| Model | Ports | Rating | Options |
|---|---|---|---|
|  | – | – | Grade 60K |
|  | – | – | – |
|  | – | – | Grade 60K |
|  | – | – | Grade 40C, Grade 50C, Grade 60C, Grade 70C, Grade 80C, Grade 50CR |
|  | – | – | Grade 40CS, Grade 50CS, Grade 60CS, Grade 70CS, Grade 80CS |
|  | – | – | Grade 40, Grade 50, Grade 60, Grade 70, Grade 80 |
|  | – | – | Grade 40K, Grade 50K, Grade 60K, Grade 70K, Grade 80K |
|  | – | – | Grade 40S, Grade 50S, Grade 60S, Grade 70S, Grade 80S |

**

### Disposable in-line filters and adsorbers 8 products, to 8.5 bar**

[DIA-BN](https://www.sarveshanalytics.com/headline-filters/products/dia-bn.html)[DIA-IN](https://www.sarveshanalytics.com/headline-filters/products/dia-in.html)[DIA-MN](https://www.sarveshanalytics.com/headline-filters/products/disposable-inline-adsorbers-dia-mn.html)[DIF-BK](https://www.sarveshanalytics.com/headline-filters/products/dif-bk.html)[DIF-BN](https://www.sarveshanalytics.com/headline-filters/products/dif-bn.html)[DIF-BN70](https://www.sarveshanalytics.com/headline-filters/products/disposable-inline-filter-dif-bn70.html)[DIF-IN](https://www.sarveshanalytics.com/headline-filters/products/dif-in.html)[DIF-MN](https://www.sarveshanalytics.com/headline-filters/products/dif-mn.html)

| Model | Ports | Rating | Options |
|---|---|---|---|
|  | 6.3mm | 110°C @ 0bar - 50°C @ 8.5bar | Activated Carbon, Silica Gel, Molecular Sieve 13X, Potassium Permanganate, Mixed Bases, Molecular Sieve 4A |
|  | 6.3mm | 110°C @ 0bar - 50°C @ 7bar | Activated Carbon, Silica Gel, Potassium Permanganate, Molecular Sieve 13X, Molecular Sieve 4A, Mixed Bases |
|  | 6.3mm | 110°C @ 0bar - 50°C @ 8.5bar | Activated Carbon, Silica Gel, Molecular Sieve 13X, Mixed Bases, Molecular Sieve 4A, Potassium Permanganate |
|  | 6.3mm | 110°C @ 0bar - 50°C @ 8.5bar | Grade 40, Grade 50, Grade 60, Grade 70, Grade 80, Grade 50R |
|  | 6.3mm | 110°C @ 0bar - 50°C @ 8.5bar | Grade 40, Grade 40S, Grade 50, Grade 50W, Grade 50S, Grade 60 |
|  | 6.3mm | 110°C @ 0bar - 50°C @ 8.5bar | Grade 70 |
|  | 6.3mm | 110°C @ 0bar - 50°C @ 7bar | Grade 40, Grade 50, Grade 50S, Grade 50W, Grade 60, Grade 70W |
|  | 6.3mm | 110°C @ 0bar - 50°C @ 8.5bar | Grade 40, Grade 50, Grade 50W, Grade 50S, Grade 60, Grade 70 |

## Frequently asked questions

**Do Headline elements fit Kane analysers?**

Headline lists the 10-37-60K glass fibre element as the equivalent of Kane PF400/5. For other models, send us the part number on the old filter and we confirm the matching Headline element.

**How often should the filter be changed?**

Change it whenever the analyser reports low flow, and at every service. A wet, dirty flue blocks the element faster than a clean gas boiler.

**Are these filters for fixed flue gas analysers too?**

Fixed analysers on stacks and boilers use larger sample-system filters. See our emission monitoring filters, or ask us about the analyser you have.

**Can I buy them in India?**

Yes. Sarvesh Analytics in Pune, India, is the exclusive representative of Headline Filters for the Indian subcontinent. Ask us for price and availability.

## Other Headline applications

- [Filters for automotive exhaust gas analysers](https://www.sarveshanalytics.com/headline-filters/applications/exhaust-gas-analyser-filters.html)
- [Filters for garage and PUC emission test equipment](https://www.sarveshanalytics.com/headline-filters/applications/garage-emission-test-equipment-filters.html)
- [**Balston and Finite equivalents**](https://www.sarveshanalytics.com/headline-filters/balston-and-finite-equivalents.html)
- [**Headline Filters in Pune, India**](https://www.sarveshanalytics.com/headline-filters.html)