title: Filters for Gas Detector and Air Monitoring Makers | Headline
url: https://www.sarveshanalytics.com/headline-filters/oem/gas-detection-and-air-monitoring-makers.html
description: Headline filters for sampling gas detectors and ambient and stack monitors: disposable in-line filters, adsorbers, PTFE elements, membranes. From Pune, India.
updated: 2026-11-23
source: html
---

Headline Filters for OEMs · Gas detection and air monitoring

# Filters for gas detection and air monitoring equipment

A sampling detector or an air monitor has a small pump, a sensitive sensor and a long time between visits. Its filters must stop dust and liquid without holding back the gas being measured. Headline makes small disposable filters and adsorbers for the sample tubing, and inert elements for reactive gases.

 Quick answer

Headline filter positions in gas detection and air monitoring: sample inlet, pump and sensor protection, reactive or trace gases, liquid carry-over, interfering vapour and stack monitors. The table below gives the Headline products for each position.

Figures from the Headline Filters catalogue and brochures

**For:** Sampling gas detector makers, ambient air quality and stack monitor makers.

## Where Headline filters go in your equipment

**Sample inlet**[Disposable in-line filters and adsorbers](https://www.sarveshanalytics.com/headline-filters/disposable-inline-filters-and-adsorbers.html)
[In-line and fast loop filters](https://www.sarveshanalytics.com/headline-filters/in-line-and-fast-loop-filters.html)**Pump and sensor protection**[Disposable in-line filters and adsorbers](https://www.sarveshanalytics.com/headline-filters/disposable-inline-filters-and-adsorbers.html)**Reactive or trace gases**[PTFE and PVDF housings](https://www.sarveshanalytics.com/headline-filters/ptfe-and-pvdf-filter-housings.html)
[Filter elements](https://www.sarveshanalytics.com/headline-filters/filter-elements.html)**Liquid carry-over**[Guardian membrane separators](https://www.sarveshanalytics.com/headline-filters/guardian-membrane-separators.html)**Interfering vapour**[Vapour removal adsorbers](https://www.sarveshanalytics.com/headline-filters/applications/vapour-removal-adsorbers.html)**Stack monitors**[Emission monitoring filters](https://www.sarveshanalytics.com/headline-filters/applications/emission-monitoring-filters.html)
[Heatable H130 and H140](https://www.sarveshanalytics.com/headline-filters/heatable-filter-housings.html)

| Position | What the filter does | Headline products |
|---|---|---|
|  | Particulate filtration at the inlet of the sample line |  |
|  | Disposable in-line filters protect small pumps and sensors |  |
|  | PVDF-bonded or PTFE elements, which Headline specifies for very low adsorption |  |
|  | A membrane separator stops liquid while gas passes |  |
|  | Adsorbers remove moisture, hydrocarbons or acid gases ahead of a sensor |  |
|  | Heated elements and housings for hot, wet stack gas |  |

## Design notes

- Check that an adsorber does not also remove the gas you measure: a CO2 sensor cannot sit behind molecular sieve or mixed bases.
- Disposable in-line filters are sealed units, rated from 110 °C at 0 bar to 50 °C at 7 or 8.5 bar, and are replaced when spent.
- Silica-bonded elements are inorganic and rated to 500 °C, for heated probes and filters.

Selection, Headline's data for your drawing, and equivalents for filters you use now are covered on [Headline filters for OEMs](https://www.sarveshanalytics.com/headline-filters/oem.html).

## Related Headline collections

- [Emission monitoring filters](https://www.sarveshanalytics.com/headline-filters/applications/emission-monitoring-filters.html)
- [Vapour removal adsorbers](https://www.sarveshanalytics.com/headline-filters/applications/vapour-removal-adsorbers.html)
- [High-purity gas filters](https://www.sarveshanalytics.com/headline-filters/applications/high-purity-gas-filters.html)
- [Gas analyser sample filters](https://www.sarveshanalytics.com/headline-filters/applications/gas-analyser-sample-filters.html)

## Frequently asked questions

**Which filter will not absorb the gas my detector measures?**

Use a PVDF-bonded element (K or C), which Headline specifies for very low adsorption, or a sintered PTFE element. Send us the gas and we confirm.

**Are Headline in-line filters reusable?**

No. Disposable in-line filters and adsorbers are sealed and replaced when spent, which keeps servicing simple.

## Other equipment builders

- [Gas analysers and sample systems](https://www.sarveshanalytics.com/headline-filters/oem/gas-analyser-and-sample-system-builders.html)
- [Gas generators and electrolysers](https://www.sarveshanalytics.com/headline-filters/oem/gas-generator-and-electrolyser-builders.html)
- [Emission testers and portable analysers](https://www.sarveshanalytics.com/headline-filters/oem/emission-test-equipment-makers.html)
- [Laboratory and analytical instruments](https://www.sarveshanalytics.com/headline-filters/oem/laboratory-and-analytical-instrument-makers.html)
- [Compressed air and pneumatic equipment](https://www.sarveshanalytics.com/headline-filters/oem/compressed-air-and-pneumatic-equipment-builders.html)
- [Vacuum pumps and vacuum systems](https://www.sarveshanalytics.com/headline-filters/oem/vacuum-equipment-builders.html)
- [Process skids and panels](https://www.sarveshanalytics.com/headline-filters/oem/process-skid-and-panel-builders.html)
- [**All Headline filters for OEMs**](https://www.sarveshanalytics.com/headline-filters/oem.html)