# Filters for nitrogen, oxygen and hydrogen generator builders

A gas generator lives or dies by its feed and its product. Oil and water aerosols in the feed air shorten the life of the separation stage; particles in the product gas reach your customer's process; a wet sample upsets the purity analyser. Headline makes the coalescing, particulate and membrane filters for each of these points.

 Quick answer

Headline filter positions in gas generators and electrolysers: feed air, oil vapour in the feed, product gas, purity analyser sample and high-pressure filling. The table below gives the Headline products for each position.

Figures from the Headline Filters catalogue and brochures

**For:** Nitrogen and oxygen generator makers (PSA and membrane), hydrogen generator and electrolyser builders.

## Where Headline filters go in your equipment

**Feed air**[Compressed air filters](https://www.sarveshanalytics.com/headline-filters/applications/compressed-air-filters.html)
[Aluminium housings](https://www.sarveshanalytics.com/headline-filters/aluminium-filter-housings.html)
[Instrument air coalescing filters](https://www.sarveshanalytics.com/headline-filters/instrument-air-coalescing-filters.html)**Oil vapour in the feed**[Vapour removal adsorbers](https://www.sarveshanalytics.com/headline-filters/applications/vapour-removal-adsorbers.html)
[Coalescing filters](https://www.sarveshanalytics.com/headline-filters/coalescing-filters.html)**Product gas**[110 and 120 series](https://www.sarveshanalytics.com/headline-filters/110-and-120-series-filter-housings.html)
[130 and 140 series](https://www.sarveshanalytics.com/headline-filters/130-and-140-series-filter-housings.html)
[High-purity gas filters](https://www.sarveshanalytics.com/headline-filters/applications/high-purity-gas-filters.html)**Purity analyser sample**[Guardian membrane separators](https://www.sarveshanalytics.com/headline-filters/guardian-membrane-separators.html)
[Gas analyser sample filters](https://www.sarveshanalytics.com/headline-filters/applications/gas-analyser-sample-filters.html)**High-pressure filling**[130 and 140 series](https://www.sarveshanalytics.com/headline-filters/130-and-140-series-filter-housings.html)
[110 and 120 series](https://www.sarveshanalytics.com/headline-filters/110-and-120-series-filter-housings.html)

| Position | What the filter does | Headline products |
|---|---|---|
|  | Grade 70C then grade 50C coalescers remove oil and water aerosols down to 0.1 micron |  |
|  | A grade CC activated carbon cartridge after the 50C coalescer takes out oil vapour |  |
|  | A particulate filter on the outlet, in stainless steel rated for the outlet pressure |  |
|  | Stop liquid water and particles reaching the oxygen or hydrogen sensor |  |
|  | Stainless housings for cylinder filling and storage, to 400 bar, or 700 bar in the 110 and 120 HP versions |  |

## Design notes

- Always fit a grade 70C prefilter ahead of a grade 50C final filter, and a 50C coalescer ahead of any CC vapour cartridge.
- Never fit a filter with ports smaller than the line, and size it for the maximum flow: above its rated flow a coalescer loses efficiency.
- A coalescing element starts below 0.15 bar dry pressure drop; Headline recommends a change at 0.7 bar. A differential pressure indicator tells your customer when.
- Hydrogen from an electrolyser is saturated with water. Keep the sample to the analyser free of liquid with a [coalescing filter](https://www.sarveshanalytics.com/headline-filters/coalescing-filters.html) and a membrane separator.

Selection, Headline's data for your drawing, and equivalents for filters you use now are covered on [Headline filters for OEMs](https://www.sarveshanalytics.com/headline-filters/oem.html).

## Related Headline collections

- [Compressed air filters](https://www.sarveshanalytics.com/headline-filters/applications/compressed-air-filters.html)
- [High-purity gas filters](https://www.sarveshanalytics.com/headline-filters/applications/high-purity-gas-filters.html)
- [Vapour removal adsorbers](https://www.sarveshanalytics.com/headline-filters/applications/vapour-removal-adsorbers.html)
- [Gas analyser sample filters](https://www.sarveshanalytics.com/headline-filters/applications/gas-analyser-sample-filters.html)

## Frequently asked questions

**Which grade protects a nitrogen membrane or PSA bed?**

Headline specifies grade 50C for the most demanding air duties, with a grade 70C prefilter. Add a grade CC cartridge after the 50C to take out oil vapour.

**Do you supply the purity analyser as well?**

Yes. Sarvesh Analytics designs and builds ACCURRA oxygen and [thermal conductivity analysers](https://www.sarveshanalytics.com/binary-tcd-thermal-conductivity-analysers.html) in Pune, India, for nitrogen, oxygen and hydrogen generators.

## Other equipment builders

- [Gas analysers and sample systems](https://www.sarveshanalytics.com/headline-filters/oem/gas-analyser-and-sample-system-builders.html)
- [Emission testers and portable analysers](https://www.sarveshanalytics.com/headline-filters/oem/emission-test-equipment-makers.html)
- [Gas detection and air monitoring](https://www.sarveshanalytics.com/headline-filters/oem/gas-detection-and-air-monitoring-makers.html)
- [Laboratory and analytical instruments](https://www.sarveshanalytics.com/headline-filters/oem/laboratory-and-analytical-instrument-makers.html)
- [Compressed air and pneumatic equipment](https://www.sarveshanalytics.com/headline-filters/oem/compressed-air-and-pneumatic-equipment-builders.html)
- [Vacuum pumps and vacuum systems](https://www.sarveshanalytics.com/headline-filters/oem/vacuum-equipment-builders.html)
- [Process skids and panels](https://www.sarveshanalytics.com/headline-filters/oem/process-skid-and-panel-builders.html)
- [**All Headline filters for OEMs**](https://www.sarveshanalytics.com/headline-filters/oem.html)