Headline Filters for OEMs · Process skids and panels

# Filters for process skid and panel builders

A skid has to pass inspection, survive the site and be serviced by someone who did not build it. Headline's stainless steel housings are weld-free 316L with each rating stated as a pair of pressure and temperature, from small instrument filters to 2 inch lines.

 Quick answer

Headline filter positions in process skids and panels: instrument and sample lines, fuel gas and CNG, high-flow gas, sour gas, liquid lines and corrosive service. The table below gives the Headline products for each position.

Figures from the Headline Filters catalogue and brochures

**For:** Natural gas and CNG skid builders, metering and analyser panel fabricators, chemical injection and liquid sampling skids.

## Where Headline filters go in your equipment

**Instrument and sample lines**[110 and 120 series](https://www.sarveshanalytics.com/headline-filters/110-and-120-series-filter-housings.html)**Fuel gas and CNG**[130 and 140 series](https://www.sarveshanalytics.com/headline-filters/130-and-140-series-filter-housings.html)
[Natural gas and CNG filters](https://www.sarveshanalytics.com/headline-filters/applications/natural-gas-and-cng-filters.html)**High-flow gas**[150 and 160 series](https://www.sarveshanalytics.com/headline-filters/150-and-160-series-filter-housings.html)**Sour gas**[110 and 120 series](https://www.sarveshanalytics.com/headline-filters/110-and-120-series-filter-housings.html)
[130 and 140 series](https://www.sarveshanalytics.com/headline-filters/130-and-140-series-filter-housings.html)
[150 and 160 series](https://www.sarveshanalytics.com/headline-filters/150-and-160-series-filter-housings.html)**Liquid lines**[Liquid sample filters](https://www.sarveshanalytics.com/headline-filters/applications/liquid-sample-filters.html)**Corrosive service**[PTFE and PVDF housings](https://www.sarveshanalytics.com/headline-filters/ptfe-and-pvdf-filter-housings.html)

| Position | What the filter does | Headline products |
|---|---|---|
|  | Small-volume housings to 340 bar, or 700 bar in the HP versions |  |
|  | Coalescing filters for compressor oil and liquid, to 400 bar |  |
|  | 1 to 2 inch lines to 400 bar |  |
|  | Weld-free 316L compliant with NACE MR0175 and MR0103 |  |
|  | Cleanable stainless mesh or sintered PTFE elements |  |
|  | PTFE and PVDF housings |  |

## Design notes

- Headline states each housing's maximum temperature and pressure together. Size the filter for the highest pressure it can see, and confirm the rating above 200 °C with us.
- Stainless mesh elements are five layers of 316 mesh, from 1 to 200 micron, and can be back-flushed and cleaned ultrasonically.
- The element size for each housing is listed on our series pages, so the spares list for your skid can be written at the design stage.

Selection, Headline's data for your drawing, and equivalents for filters you use now are covered on [Headline filters for OEMs](https://www.sarveshanalytics.com/headline-filters/oem.html).

## Related Headline collections

- [Natural gas and CNG filters](https://www.sarveshanalytics.com/headline-filters/applications/natural-gas-and-cng-filters.html)
- [Liquid sample filters](https://www.sarveshanalytics.com/headline-filters/applications/liquid-sample-filters.html)
- [Gas analyser sample filters](https://www.sarveshanalytics.com/headline-filters/applications/gas-analyser-sample-filters.html)

## Frequently asked questions

**Which Headline housings are NACE compliant?**

The weld-free 316L 110 to 160 series are compliant with NACE MR0175 and MR0103.

**What is the highest pressure rating?**

The 110 and 120 HP versions are rated to 700 bar. The 130 to 160 series reach 400 bar in the VP versions.

## Other equipment builders

- [Gas analysers and sample systems](https://www.sarveshanalytics.com/headline-filters/oem/gas-analyser-and-sample-system-builders.html)
- [Gas generators and electrolysers](https://www.sarveshanalytics.com/headline-filters/oem/gas-generator-and-electrolyser-builders.html)
- [Emission testers and portable analysers](https://www.sarveshanalytics.com/headline-filters/oem/emission-test-equipment-makers.html)
- [Gas detection and air monitoring](https://www.sarveshanalytics.com/headline-filters/oem/gas-detection-and-air-monitoring-makers.html)
- [Laboratory and analytical instruments](https://www.sarveshanalytics.com/headline-filters/oem/laboratory-and-analytical-instrument-makers.html)
- [Compressed air and pneumatic equipment](https://www.sarveshanalytics.com/headline-filters/oem/compressed-air-and-pneumatic-equipment-builders.html)
- [Vacuum pumps and vacuum systems](https://www.sarveshanalytics.com/headline-filters/oem/vacuum-equipment-builders.html)
- [**All Headline filters for OEMs**](https://www.sarveshanalytics.com/headline-filters/oem.html)