# Online hydrogen gas analyser, platinum thermal conductivity, no reference gas

ACCURRA-TCD is Sarvesh's thermal conductivity analyser line. For hydrogen, a platinum thermal conductivity sensor measures hydrogen from 0 to 100 percent, depending on the background gas, with no reference gas.

- ISO 9001:2015, certified by TÜV
- Designed and built in Pune since 2002
- Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO

 Quick answer

ACCURRA-TCD measures hydrogen from 0 to 100 %, depending on the background gas, with a platinum thermal conductivity sensor and no reference gas. Display resolution is 0.01 % and repeatability is better than 1 % of full scale.

Updated 3 November 2026 · Figures from Sarvesh datasheets

## Specifications

| Item | Specification | Notes |
|---|---|---|
| In nitrogen, air, CO2 or methane | 0 to 100 %, 0 to 3 % or 97 to 100 % |  |
| In argon | 0 to 100 %, 0 to 3 % or 97 to 100 % |  |
| In helium | 20 to 100 %, 20 to 40 % or 85 to 100 % |  |
| In oxygen | 0 to 100 %, 0 to 4 % or 97 to 100 % |  |
| Resolution | 0.01 % |  |
| Repeatability | Below 1 % of full scale | Linearity below 1 % of range |
| Response time | T90 below 10 s at 0.6 LPM |  |
| Sample flow | 0.6 LPM recommended |  |
| Sample temperature | 5 to 45 C |  |
| Power | 100 to 240 V AC, 50/60 Hz, 45 W |  |
| Output | Isolated 4-20 mA, user-programmable range; Modbus RTU over RS 485 | Programmable relays for alarms, fault, pump or range ID, calibration |

From the current Sarvesh product datasheets and company profile. Specifications may change without notice as products improve. The final responsibility to check that a product meets the process and analyser requirement remains with the customer.

## Key features

- Dual-level password protection and history of alarms and calibrations
- Programmable alarms Lo-Hi, Lo-Lo, Hi-Hi
- Output freeze or follow during calibration

## How it works

Hydrogen has the highest thermal conductivity of any gas, so a thermal conductivity sensor responds strongly to it. Platinum-based sensing avoids the need for a reference gas and holds calibration well.

Typical uses are hydrogen production and filling, hydrogen purity in cooling of generators, metal processing and heat treatment atmospheres, and leak detection in safe-area enclosures. Response is fast, with T90 below 10 seconds at the recommended 0.6 LPM.

## Requirements and limits

- Safe-area analyser; a single known background gas assumed.

## On site: utilities and calibration gases

What to have ready at your plant before installation and commissioning.

| Item | Requirement | Notes |
|---|---|---|
| Power at the analyser | 100 to 240 V AC, 50/60 Hz, 45 W |  |
| Zero gas | Zero-grade nitrogen, 99.999 % | 10 litre cylinder with regulator |
| Span gas | The measured gas at zero grade, 99.999 %: hydrogen, helium, argon or nitrous oxide | 10 litre cylinder with regulator |
| Sample at the analyser | 2 to 10 psig, 0.6 LPM, 5 to 40 °C, dust below 3 micron | Pressure and flow regulated by the user |
| Mounting | 19 inch rack or panel, in a safe area |  |

## Selection guidance

Choose ACCURRA-TCD for hydrogen in one known background gas in a safe area. For classified areas choose ACCURRA-Hz.

## Applications

Application pages where this is part of the recommended solution:

- [Cold rolling mill furnaces](https://www.sarveshanalytics.com/applications/cold-rolling-mill-furnace-atmosphere.html)
- [Hydrogen purity](https://www.sarveshanalytics.com/applications/hydrogen-purity-analyser.html)
- [Electrolyser safety and quality](https://www.sarveshanalytics.com/applications/hydrogen-electrolyser-gas-analysis.html)
- [Float glass bath atmosphere](https://www.sarveshanalytics.com/applications/float-glass-bath-and-furnace-atmosphere.html)

## Compatible products

[

### ACCURRA-TCD

Thermal conductivity analyser for binary mixtures of H2, He, Ar, N2 and others, with no reference gas. View ACCURRA-TCD

](https://www.sarveshanalytics.com/binary-tcd-thermal-conductivity-analysers.html)[

### ACCURRA-Hz

Process gas analyser in an enclosure certified for Gas Group IIC, Zone 1 and 2, T6. View ACCURRA-Hz

](https://www.sarveshanalytics.com/hazardous-gas-analysers.html)[

### Headline filters

Particulate, coalescing and PTFE membrane filters from Headline Filters, UK, for analyser protection. View Headline filters

](https://www.sarveshanalytics.com/headline-filters.html)

## Frequently asked questions

**What range does it cover?**

0 to 100 percent hydrogen, or narrow ranges such as 0 to 3 or 97 to 100 percent; the ranges depend on the background gas.

**Which backgrounds?**

One of nitrogen, air, CO2, methane, argon, helium or oxygen.

**Does it need a reference gas?**

No.

**Can I use it in a hazardous area?**

Use ACCURRA-Hz.

## Related pages

- [ACCURRA-TCD](https://www.sarveshanalytics.com/binary-tcd-thermal-conductivity-analysers.html)
- [Helium analyser (TCD)](https://www.sarveshanalytics.com/helium-gas-analyser.html)
- [Argon analyser (TCD)](https://www.sarveshanalytics.com/argon-gas-analyser.html)
- [Nitrogen analyser (TCD)](https://www.sarveshanalytics.com/nitrogen-gas-analyser.html)
- [Nitrous oxide analyser (TCD)](https://www.sarveshanalytics.com/nitrous-oxide-gas-analyser.html)
- [Thermal conductivity gas analysers](https://www.sarveshanalytics.com/thermal-conductivity-gas-analyser.html)
- [Binary gas mixtures for TCD](https://www.sarveshanalytics.com/binary-gas-mixtures-thermal-conductivity.html)
- [ACCURRA-TCD applications](https://www.sarveshanalytics.com/accurra-tcd-applications.html)
- [**Browse all gas analysers**](https://www.sarveshanalytics.com/gas-analyser.html)