title: ACCURRA-S-TCD 1030 Hydrogen Analyser | Made in India
url: https://www.sarveshanalytics.com/models/accurra-s-tcd-1030-hydrogen-analyser.html
description: ACCURRA-S-TCD 1030 measures hydrogen by thermal conductivity in nitrogen, air, CO2 or methane, argon, helium and oxygen; repeatability below 1 % of.
updated: 2026-11-23
source: html
---

ACCURRA-S-TCD · Model 1030

# ACCURRA-S-TCD 1030 hydrogen analyser

ACCURRA-S-TCD 1030 measures hydrogen in a binary gas mixture by thermal conductivity, with a platinum sensor that needs no sealed reference and no reference gas. Made by Sarvesh in Pune, India.

 Quick answer

ACCURRA-S-TCD 1030 measures [hydrogen by thermal conductivity](https://www.sarveshanalytics.com/hydrogen-gas-analyser.html) in nitrogen, air, CO2 or methane, argon, helium and oxygen; repeatability below 1 % of full scale, T90 below 10 s at 0.6 LPM, no reference gas. Ordering code ACCURRA-S-TCD-1030.

Figures from the ACCURRA-S-TCD datasheet (SAPL/PDS/ACCURRA-TCD-08/25-Aug)

## Specifications

| Item | Specification | Notes |
|---|---|---|
| Measures | Hydrogen in a binary gas mixture | Thermal conductivity |
| In nitrogen, air, CO2 or methane | 0 to 100 %, 0 to 3 % or 97 to 100 % | Range options |
| In argon | 0 to 100 %, 0 to 3 % or 97 to 100 % | Range options |
| In helium | 20 to 100 %, 20 to 40 % or 85 to 100 % | Range options |
| In oxygen | 0 to 100 %, 0 to 4 % or 97 to 100 % | Range options |
| Sensor | Platinum thermal conductivity; no sealed reference and no reference gas flow |  |
| Response time | T90 below 10 s at 0.6 LPM |  |
| Repeatability | Below 1 % of full scale |  |
| Linearity | Below 1 % of range |  |
| Errors and drift | Below 1 % of full scale per week |  |
| Display resolution | 0.01 % |  |
| Sample flow | 0.6 LPM recommended | Regulated externally; built-in flow indicator |

From datasheet SAPL/PDS/ACCURRA-TCD-08/25-Aug. Specifications may change as products improve.

## Built into every ACCURRA-S-TCD

| Item | Specification | Notes |
|---|---|---|
| Display | Backlit LCD, 4 lines x 20 characters |  |
| Analog output | 1 x 4–20 mA isolated, max load 500 ohm, dual range | Range freely selectable over the full measurement range |
| Relays | 6 x SPST rated 1 A 230 V AC, all failsafe | Alarm 1, Alarm 2, fault, sample pump or range ID, two for auto-calibration valves |
| Communication | Modbus RTU over RS 485 | Read measured value, status, set-up and history; write auto-calibration start and set-up |
| Enclosure | 19 inch rack or panel; 134 H x 483 W x 180 (short) or 280 (long) D mm | IP 20, safe area only; net about 6 kg, gross about 8 kg |
| Power | 100 to 240 V AC, 50/60 Hz, 45 W |  |
| Inlet and outlet | 1/4 inch OD SS316 |  |
| Ambient | 5 to 40 °C; below 90 % RH non-condensing | Storage 0 to 50 °C |

## Options for this model

- Auto calibration: available, with internal solenoid valves or as a relay output for external valves; a dual measurement has relay outputs only.
- Sample pump: an internal sample pump is available on a single measurement; not on a dual measurement.
- Second measurement: trace or percent oxygen, ppm or percent carbon dioxide, or dew point, in the same enclosure.

[Build the part number](https://www.sarveshanalytics.com/part-number-builder.html) [Write the specification](https://www.sarveshanalytics.com/analyser-selector.html)

## Dual measurement

The catalogue lists hydrogen with 3015 (oxygen, trace) in one ACCURRA-S-TCD, each with its own electronics, 4–20 mA output, relays and Modbus address.

## For hazardous areas

Hydrogen by thermal conductivity is also available in ACCURRA-Hz (model 1030, 0 to 100 % in nitrogen), in a certified enclosure for Gas Group IIC, Zone 1 and 2, T6. See [hazardous-area hydrogen](https://www.sarveshanalytics.com/hazardous-hydrogen-gas-analyser.html).

## Where it is used

Application notes where 1030 is part of the recommended system:

- [Hydrogen purity](https://www.sarveshanalytics.com/applications/hydrogen-purity-analyser.html)
- [Electrolyser safety and quality](https://www.sarveshanalytics.com/applications/hydrogen-electrolyser-gas-analysis.html)
- [Heat-treatment furnace atmosphere](https://www.sarveshanalytics.com/applications/heat-treatment-furnace-atmosphere.html)
- [Steel plant process gases](https://www.sarveshanalytics.com/applications/steel-plant-process-gas-analysis.html)
- [Float glass bath atmosphere](https://www.sarveshanalytics.com/applications/float-glass-bath-and-furnace-atmosphere.html)
- [Reactors, hydrogenation and polymerisation](https://www.sarveshanalytics.com/applications/chemical-reactor-hydrogenation-trace-oxygen.html)
- [Pyrolysis, gasification and syngas](https://www.sarveshanalytics.com/applications/pyrolysis-gasification-and-syngas.html)
- [Chlor-alkali hydrogen stream: oxygen in hydrogen](https://www.sarveshanalytics.com/applications/chlor-alkali-hydrogen-stream-oxygen-in-hydrogen.html)
- [Hydrogen-cooled generator purity and purge](https://www.sarveshanalytics.com/applications/hydrogen-cooled-generator-purity-and-purge-monitoring.html)
- [Ammonia synthesis loop and purge gas hydrogen](https://www.sarveshanalytics.com/applications/ammonia-synthesis-loop-and-purge-gas-hydrogen.html)
- [Urea plant CO2 feed: purity and passivation oxygen](https://www.sarveshanalytics.com/applications/urea-plant-co2-feed-purity-and-passivation-oxygen.html)
- [Refinery hydrogen purity: make-up, recycle and PSA](https://www.sarveshanalytics.com/applications/refinery-hydrogen-purity-make-up-recycle-and-psa.html)

## Frequently asked questions

**Which background gases does 1030 work in?**

Nitrogen, air, CO2 or methane: 0 to 100 %, 0 to 3 % or 97 to 100 %; Argon: 0 to 100 %, 0 to 3 % or 97 to 100 %; Helium: 20 to 100 %, 20 to 40 % or 85 to 100 %; Oxygen: 0 to 100 %, 0 to 4 % or 97 to 100 %. Ask us for other mixtures.

**Does it need a reference gas?**

No. The platinum thermal conductivity sensor needs no sealed reference and no reference gas flow.

**What is the part number?**

It starts ACCURRA-S-TCD-1030, then a second component or XXXX, the power supply (A), the range ID or pump relay, and auto calibration. The part number builder writes the full code.

## Other models

- [ACCURRA-S-TCD 7130 helium analyser](https://www.sarveshanalytics.com/models/accurra-s-tcd-7130-helium-analyser.html)
- [ACCURRA-S-TCD 7230 argon analyser](https://www.sarveshanalytics.com/models/accurra-s-tcd-7230-argon-analyser.html)
- [ACCURRA-S-TCD 7330 nitrogen analyser](https://www.sarveshanalytics.com/models/accurra-s-tcd-7330-nitrogen-analyser.html)
- [ACCURRA-S-TCD 7530 nitrous oxide analyser](https://www.sarveshanalytics.com/models/accurra-s-tcd-7530-nitrous-oxide-analyser.html)
- [**ACCURRA-TCD hydrogen analyser**](https://www.sarveshanalytics.com/hydrogen-gas-analyser.html)
- [How ACCURRA model numbers work](https://www.sarveshanalytics.com/accurra-model-numbers.html)