title: Gas Analysers for OEMs and System Builders | Sarvesh
url: https://www.sarveshanalytics.com/oem.html
description: Build an ACCURRA gas analyser into your furnace, generator, dryer or skid. Designed and made in India, with Modbus, 4-20 mA and alarms. Request an OEM quote.
updated: 2026-11-04
source: html
---

For OEMs and system builders

# The analyser inside your equipment, made in India.

Furnaces, nitrogen and oxygen generators, gas mixers, air dryers, electrolysers and process skids all need a gas reading their customers can trust. ACCURRA analysers are designed and built by Sarvesh in Pune, configured from a published ordering code, and wired to the outputs your control system already uses.

  Why builders design in ACCURRA

## Less to engineer, less to stock, less to explain to your customer.

 01

### One code, one configuration

Every ACCURRA-S and ACCURRA-Hz is specified by a published ordering code: gas, range, second channel, pump, auto-calibration and power. Your drawing and your purchase order quote the same code, so every repeat unit matches the first.

 02

### Speaks your control system

Isolated 4-20 mA scaled to any part of the range, Modbus RTU over RS 485, and failsafe alarm relays set as Lo-LoLo, Lo-Hi or Hi-HiHi. Your PLC reads the value, the status and the alarms without an interface card.

 03

### Two gases, one enclosure

ACCURRA-S carries two different sensors in series, each with its own electronics, output, relays and Modbus ID. Oxygen and dew point, or methane and CO2, take one panel cut-out and one line on your bill of materials.

 04

### Fewer consumables for your customer

ACCURRA-TCD needs no reference gas, so your design drops a cylinder and a regulator. Paramagnetic oxygen models have no consumable sensor. Calibration and alarm history are stored in the analyser for audits.

 05

### The whole sample path

Probes, filters, coolers, the i-Cons conditioner and the SV-200 vaporiser come from the same supplier as the analyser, with Headline Filters supplied through Sarvesh. One supplier answers for the reading, from the tapping point to the output.

 06

### Designed and made in India

Developed by our own R&D team and built at our Talwade factory since 2002, under a quality system certified to ISO 9001:2015 by TÜV. An Indian-made analyser adds Indian-made content to the equipment you sell.

  Match it to your machine

## What you build, and the analyser that goes in it.

Each row links to the application note your engineers can use to check the measurement point and the sample path.

   [Furnace atmospheres](https://www.sarveshanalytics.com/applications/heat-treatment-furnace-atmosphere.html) [CAB furnaces](https://www.sarveshanalytics.com/applications/aluminium-controlled-atmosphere-brazing-furnaces.html) [Nitrogen purity](https://www.sarveshanalytics.com/applications/nitrogen-purity-trace-oxygen.html) [Medical oxygen plants](https://www.sarveshanalytics.com/applications/medical-oxygen-plant-purity-monitoring.html) [Welding gas mixtures](https://www.sarveshanalytics.com/applications/welding-and-laser-gas-mixtures.html) [Boiler flue oxygen](https://www.sarveshanalytics.com/applications/boiler-and-furnace-oxygen-flue-gas.html) [Compressed air dew point](https://www.sarveshanalytics.com/applications/compressed-air-and-instrument-air-dew-point-iso-8573.html) [CA fruit stores](https://www.sarveshanalytics.com/applications/controlled-atmosphere-ca-and-ulo-fruit-stores.html) [Glove boxes](https://www.sarveshanalytics.com/applications/glove-boxes-and-isolators-o2-and-moisture.html) [Electrolyser gas](https://www.sarveshanalytics.com/applications/hydrogen-electrolyser-gas-analysis.html) [Blanketing and inerting](https://www.sarveshanalytics.com/applications/nitrogen-blanketing-and-inerting.html) [Biogas and CBG](https://www.sarveshanalytics.com/applications/biogas-and-cbg-methane-co2-analysis.html)

| You build | The measurement | Analyser | Application note |
|---|---|---|---|
| Heat-treatment, sintering and bright-annealing furnaces | Trace oxygen, dew point, hydrogen | 3015 + M015, ACCURRA-TCD |  |
| Controlled-atmosphere brazing furnaces | Oxygen ppm and dew point from one tapping | 3015 + M015 |  |
| PSA and membrane nitrogen generators | Residual oxygen in the product | 3015 or 3030 |  |
| PSA and VPSA oxygen plants | Oxygen purity, about 93 % | 3090 or 3130 |  |
| Gas mixers for welding and food packaging | CO2 and oxygen in the blend | 6030, 3030, ACCURRA-TCD |  |
| Boilers, burners and thermic-fluid heaters | Flue gas oxygen for combustion trim | ACCURRA-Zr |  |
| Compressed air dryers | Pressure dew point | M015 |  |
| CA stores and ripening rooms | Oxygen and CO2 in the room | 3030 + 6030 |  |
| Glove boxes and isolators | Oxygen ppm and dew point | 3015 + M015 |  |
| Hydrogen electrolysers | Hydrogen in oxygen, oxygen in hydrogen | ACCURRA-TCD, ACCURRA-Hz |  |
| Dryer, reactor and solvent skids in classified areas | Oxygen in the inert gas | ACCURRA-Hz, INFINITY-Tx |  |
| Biogas upgrading skids and gas gensets | Methane and CO2 | 4030 + 6030 |  |

Building something not on this list? Send the gas, the range and the conditions at the tapping point. Bespoke applications are where we start every project.

  Integration at a glance

## What your design team needs to know.

From the ACCURRA datasheets. Full figures, ordering codes and dimensions are in the [datasheets](https://www.sarveshanalytics.com/downloads.html).

| Item | ACCURRA-S (safe area) | ACCURRA-Hz (hazardous area) |
|---|---|---|
| Enclosure | 19 inch rack or panel, 134 H x 483 W x 180 or 280 D mm, IP 20, about 6 kg | Wall mounted, 410 H x 370 W x 245 D mm, IP 66, about 12 kg; Gas Group IIC, Zone 1 and 2, T6 as per IS/IEC 60079-1:2014 |
| Power | 100 to 240 V AC, 50/60 Hz, 45 W | 24 V DC, 30 W, or 100 to 240 V AC, 50/60 Hz, 45 W |
| Analog output | Isolated 4-20 mA, user-configurable over the measurement range; dual range with range ID relay | Isolated 4-20 mA, dual range, maximum load 500 ohm |
| Communication | Modbus RTU over RS 485: read the measured value, status, set-up and history |  |
| Relays | Two independent failsafe alarm relays, set as Lo-LoLo, Lo-Hi or Hi-HiHi; relays for fault, sample pump, range ID or calibration valves, by model |  |
| Calibration | Calibration check facility; optional cyclic and remote auto-calibration; output freeze or follow during calibration | Calibration without opening the covers, tamper-proof; optional auto-calibration through external valves |
| Records | Calibration history with deviation values, alarm and fault history; password-protected set-up |  |
| Sample | Dry, oil-free, non-condensing; 2 to 10 psig, about 1 LPM (0.6 LPM for ACCURRA-TCD), dust below 3 micron. Where your sample differs, we design the conditioning around it. |  |

  How an OEM project runs

## From your specification to the units on your line.

### 1. Your specification

Send the equipment, the gas, the range, the sample conditions and the number of units you expect to build. A data sheet or a drawing is enough to start.

### 2. Application review

An applications engineer checks the measurement point and the sample path, then fixes the model, range and options as one ordering code.

### 3. Your first build

The first unit is built, tested and calibrated at our Talwade factory to documented procedures, and fitted into your prototype or first machine.

### 4. Repeat units

Later units are built to the same ordering code and configuration, so the analyser in your hundredth machine behaves like the one in your first.

### 5. Your customer's plant

Our support line, spares and calibration advice stay available to you for the installed base, from our office in Pune.

### Questions first?

Call sales on [+91 94 2300 4179](tel:+919423004179), or write to [info@sarveshindia.com](mailto:info@sarveshindia.com?subject=OEM%20supply).

### What happens next

Your request goes straight to our sales and applications team, who will reply with questions or a proposal for your build.

### Already have a specification?

Attach it to the form, or use the [application data sheet](https://www.sarveshanalytics.com/application-data-sheet.html) for the process details.

### Datasheets

ACCURRA-S, ACCURRA-Hz, ACCURRA-TCD, ACCURRA-Zr and the sample conditioners are on the [downloads page](https://www.sarveshanalytics.com/downloads.html).