title: Gas Analysers, Sample Handling and Filters | Sarvesh
url: https://www.sarveshanalytics.com/products.html
description: ACCURRA online gas analysers, i-Cons smart sample conditioners, probes, vaporisers and Headline filters from Sarvesh Analytics, Pune.
updated: 2026-11-03
source: html
---

Products

# The complete measurement path.

Analysers, sample conditioning, probes and filtration, designed to work together and supported by the people who built them.

  Safe area · Online

## ACCURRA-S

The analyser we introduced in 2007 and keep improving. Trace, percentage and purity measurement of O₂, CO, CO₂ and CH₄, with moisture and dew point options. The dual-gas version measures two gases from one sample.

0–25 / 0–100 %
95–100 %
0–20 / 0–100 %
0–100 %

| Gas | Range | Sensor |
|---|---|---|
| Oxygen | 0–100 / 1000 ppm | Electrochemical, paramagnetic |
| Carbon dioxide | 0–5000 ppm | NDIR |
| Carbon monoxide | 0–1000 ppm | Electrochemical, NDIR |
| Methane | 0–100 % | NDIR |
| Moisture | −80 to +20 °C dp | Ceramic |

- Isolated dual-range 4–20 mA output with range ID relay, user-configurable over the full range
- Modbus RTU over RS 485; alarm set points as Lo–LoLo, Lo–Hi or Hi–HiHi
- Calibration check, calibration and alarm history, output hold during calibration
- Dual-level password protection; optional cyclic and remote auto-calibration; optional internal sample pump
 [Full specifications, applications and FAQs →](https://www.sarveshanalytics.com/safe-gas-analyser.html)

  Safe area · Binary gas

## ACCURRA-TCD

A thermal conductivity analyser for binary gas mixtures, with a proprietary platinum sensor that needs no sealed reference and no reference gas flow.

| Measures | H₂, He, Ar, N₂, N₂O, Ne, Kr |
|---|---|
| Response T90 | < 10 s at 0.6 LPM |
| Repeatability, linearity | < 1 % |
| Error and drift | < 1 % of FS per week |

 [Full specifications, applications and FAQs →](https://www.sarveshanalytics.com/binary-tcd-thermal-conductivity-analysers.html)

  Safe area · Purity

## ACCURRA-S 3090

Oxygen purity analyser using electrochemical or paramagnetic sensing, with ambient pressure and temperature compensation.

| Repeatability | < 0.5 % |
|---|---|
| Response T90 | < 20 s at 1 LPM |
| Error and drift | < 0.5 % |

 [Full specifications, applications and FAQs →](https://www.sarveshanalytics.com/oxygen-gas-analyser.html)

  Safe area · Flue gas

## ACCURRA-Zr

Zirconia-based oxygen measurement, 0.1 to 21 %, for furnaces and boilers. The sensor sits outside the duct, protected from dust, flow and temperature swings.

- Response T90 below 15 s; repeatability better than 1 % of FS
- Single-point calibration with plain air
- Built-in automatic blowback
- Option for high dust load samples
- Option for temperatures up to 1400 °C
 [Full specifications, applications and FAQs →](https://www.sarveshanalytics.com/flue-gas-analysers.html)

  Hazardous area · Online

## ACCURRA-Hz

Process gas analysis in classified areas.

- O₂ from ppm to purity; CO from ppm to percent; CO₂, CH₄ and H₂
- Calibration without opening the covers
- Purity O₂ with ambient pressure and temperature compensation
- Enclosure certified for Gas Group IIC, Zone 1 and 2, T6, to IS/IEC 60079-1:2014; IP 66, wall mounted
- Optional ACCURRA-CONNECT software operates the analyser remotely over Modbus
 [Full specifications, applications and FAQs →](https://www.sarveshanalytics.com/hazardous-gas-analysers.html)

  Hazardous area · Transmitter

## INFINITY-Tx

A loop-powered, two-wire gas transmitter for direct field installation.

- Percentage oxygen and trace CO
- Inbuilt filter and scrubber
- Works with very low flow and low pressure samples
 [Full specifications, applications and FAQs →](https://www.sarveshanalytics.com/oxygen-transmitter.html)

  Smart sample conditioner

## i-Cons

Your sampling panel compressed into a compact 19-inch cabinet. A Peltier-based extractive system with the essential components built in and a controller that watches the whole sample path.

- Peltier cooler with PTFE heat exchanger; peristaltic pump with variable rate
- Built-in sample pump, condensate sensor, flow detector, auto-cal valves and fine filter
- Controls probe blowback, sample valves and heated hose; auto blowback on flow failure with pulsating blowback for effective cleaning
- Auto start-up sequence and auto shutdown on hardware failure
- Fail-safe fault relay; alarm and fault history; maintenance reminders for pump tube, filters and pump kit
- Modbus RTU over RS 485 for remote monitoring and remote calibration check
 [Full specifications, applications and FAQs →](https://www.sarveshanalytics.com/smart-systems-for-gas-analyser.html)

  Peltier sample cooler

## SGI-300 and SGI-320

A compact Peltier cooler with solid heat exchanger in PTFE, an integrated peristaltic pump, filter and condensate detector. SGI-320 packages the approach as an emission monitoring system.

- Relay output controls the sample pump from condensate and cooler temperature
- Less tubing and wiring, faster integration, smaller panel footprint
 [Full specifications, applications and FAQs →](https://www.sarveshanalytics.com/sample-coolers.html)

  Complete systems

## Engineered analyser panels

The probe, heated line, i-Cons conditioner and ACCURRA analyser, built into one free-standing IP 54 panel and handed over with two sets of as-built drawings and manuals.

- Bulkheads for sample, calibration, blowback, vent and drain; bottom cable entry
- 1/4 inch PTFE internal tubing with SS316 fittings; provision for one 19 inch analyser
- Exhaust fan or panel air conditioner, LED light, toughened-glass door
 [Full specifications, applications and FAQs →](https://www.sarveshanalytics.com/analyser-sampling-panels.html)

  Sample extraction

## Sample probes SP-100 to SRP-400

| Model | Type |
|---|---|
| SP-100 | Simple probe, with or without in-situ filter at the tip |
| SP-200 | Probe with blowback, non-heated |
| SP-300 | Probe with heated filter |
| SRP-400 | Retractable probe |

| Probe material | Suitable up to |
|---|---|
| SS 316 | 550 °C |
| Inconel 625 | 1100 °C |
| Ceramic | 1400 °C |
| PTFE | 180 °C |

- Separate sample and blowback lines; 1/2 inch blowback line for efficient cleaning
- Non-return valve in the sample line removes the need for a heated solenoid or air-operated valve
- SRP-400: no welding on the sample path, separate sample and bleed ports, pressure indication and orifice-controlled safe bleed
- Filter elements in SS 316, Hastelloy, Monel or PTFE; SP-300 on a 2 or 4 inch ANSI flange with a 10 micron sintered SS316 heated filter
- SRP-400 rated to 100 kg/cm2, with a non fly-off design and NACE compliance available
 [Full specifications, applications and FAQs →](https://www.sarveshanalytics.com/sample-probes.html)

  Sample vaporisers

## Vaporisers for cryogenic and wet samples

SV-400 vaporises condensed sample on the go for accurate wet analysis with no loss of sample. SV-200 suits cryogenic gas measurement and avoids condensation in the sample line.

| Feature | SV-200 | SV-400 |
|---|---|---|
| Heater | 200 W, 230 V AC | 100 W, 110 or 230 V AC |
| Flow | Max 10 LPM | Max 6 LPM |
| Control | Thermostat; Pt100 at inlet and outlet | Built-in controller, 100–200 °C |

Catchpots, scrubbers, bubblers, safe drains and wash-water separators are also available. Ask us for details. [Full specifications, applications and FAQs →](https://www.sarveshanalytics.com/sample-vaporisers.html)

  Exclusive representative for India

## Headline Filters, UK

Headline is the largest European maker of bonded microfibre filter elements and housings. We supply the full range for the Indian subcontinent.

- Particulate, coalescing and PTFE membrane filtration to protect analysers, valves and regulators
- Disposable inline filters and absorbers, emission filters, compressed air, gas, analyser, fast loop, high pressure, natural gas, adsorption and dehydration filters, Guardian membrane separators
- Housings in SS316, Monel, Hastelloy, PTFE, PVDF, polypropylene, nylon and aluminium
- Elements in SS316, PTFE, glass microfibre, Monel and Hastelloy; scrubber elements available
- Up to 700 bar and 500 °C, depending on model
 [Full specifications, applications and FAQs →](https://www.sarveshanalytics.com/headline-filters.html)

The final responsibility to confirm that a product meets the process and analyser requirement rests with the customer. Specifications may change without notice as products improve.

## Not sure which one fits?

Send us the gas, range, pressure, temperature and area classification.

 [Request a quote](https://www.sarveshanalytics.com/contact.html#enquiry)