Power, boilers and emissions

O2, CO and CO2 analysis for boiler and burner factory test benches

End-of-line testing needs a multi-gas reading at the stack. Sarvesh supplies ACCURRA-S 3030, 2030, 6030, built in Pune, with sampling matched to the stream.

  • ISO 9001:2015, certified by TÜV
  • Designed and built in Pune since 2002
  • Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO
Quick answer

Use ACCURRA-S 3030, 2030, 6030. End-of-line testing needs a multi-gas reading at the stack. Sold through the OEM; calibration routine matters.

Updated 2 November 2026 · Figures from Sarvesh datasheets

The measurement and why it matters

End-of-line testing needs a multi-gas reading at the stack. This is a good fit, with one configuration or sample-handling point to confirm before we quote.

Oxygen and carbon monoxide in combustion gas show how well fuel is burning. Too much air wastes heat, too little leaves carbon monoxide and unburnt fuel. A continuous reading lets the operator or the control system trim the burner instead of guessing.

Combustion gas is hot, often dusty and sometimes wet. ACCURRA-Zr mounts on the duct and reads oxygen with no sample line, its sensor protected just outside the wall, with probe options for high dust and for temperatures up to 1400 C, while extractive ACCURRA-S analysers read CO and other gases from a conditioned sample.

Typical buyers in India: boiler and burner makers (Thermax and others). Where this matches your plant, send us the gas, range, pressure and temperature at the tapping point and we will confirm the analyser and sample path.

Models and ranges

ModelMeasuresRangeSensor and notes
3030Oxygen percentage0 to 25 % and 0 to 100 %Electrochemical
2030Carbon monoxidePercent rangesConfirm the range against the datasheet
6030Carbon dioxide0 to 20 % or 0 to 100 %NDIR

Process notes

What the analyser reads here

Gases of interest: O2, CO, CO2. Analyser fit: ACCURRA-S 3030, 2030, 6030.

The table above lists each model with its range; where a row says to confirm the range, we check it against the datasheet for your application before quoting.

What to settle before ordering

Sold through the OEM; calibration routine matters.

We would rather confirm these points at the start than discover them at commissioning, so please include them with your process details.

Sampling and installation

  • Every ACCURRA-S has an internal fine filter and rotameter. Regulate sample pressure and flow externally; the catalogue recommends about 1 LPM and a sample pressure of 2 to 10 psig.
  • Keep sample lines short, clean and dry, and vent the sample somewhere safe.

ACCURRA-S sample specification: non-corrosive, non-toxic, non-flammable, non-condensing and dry, free from entrained oil; sample pressure 2 to 10 psig, regulated externally; flow about 1 LPM; dust below 3 micron. Where your sample differs, we design conditioning around it.

Send us your process data

Application data sheet

The same pre-order design inputs our engineers design from, online. Fill in what you know, leave the rest. Your draft saves as you go, and you can print or send it when ready.

Start the data sheet
What the data sheet asks for

Send what you have and we will ask for the rest.

  • The gases to measure, the range, and the accuracy you need
  • Background gases and their typical composition
  • Sample temperature, pressure and dew point at the tapping point
  • Dust level, and whether the gas carries tar, oil or condensable vapour
  • Process connection and, for ducts, the duct diameter
  • Where the sample vents to, and at what pressure
  • Area classification of the tapping point and of the analyser location, and the IP protection needed
  • Distance between the tapping point and the analyser
  • Outputs you need: 4-20 mA, dual range, relays, Modbus RTU
  • Calibration approach, calibration gas available, and whether blowback is required
  • Utilities at site: power supply, instrument air, nitrogen, steam and cooling water, and the ambient temperature range
  • Gases and ranges: O2, CO, CO2
  • The point to confirm: Sold through the OEM; calibration routine matters.

Frequently asked questions

Which analyser suits boiler and burner factory test benches?

ACCURRA-S 3030, 2030, 6030 End-of-line testing needs a multi-gas reading at the stack.

What should I check before ordering for boiler and burner factory test benches?

Sold through the OEM; calibration routine matters.

Who typically needs this?

Typical buyers in India: boiler and burner makers (Thermax and others).

Can Sarvesh support a variation of this application?

Yes. If your process differs from the usual case, send the details. Application engineering is where we start every project, and bespoke applications are welcome.