ACCURRA-TCD · Hydrogen

Online hydrogen gas analyser, platinum thermal conductivity, no reference gas

ACCURRA-TCD is Sarvesh's thermal conductivity analyser line. For hydrogen, a platinum thermal conductivity sensor measures hydrogen from 0 to 100 percent, depending on the background gas, with no reference gas.

ACCURRA-TCD hydrogen analyser
  • ISO 9001:2015, certified by TÜV
  • Designed and built in Pune since 2002
  • Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO
Quick answer

ACCURRA-TCD measures hydrogen from 0 to 100 %, depending on the background gas, with a platinum thermal conductivity sensor and no reference gas. Display resolution is 0.01 % and repeatability is better than 1 % of full scale.

Updated 3 November 2026 · Figures from Sarvesh datasheets

Specifications

ItemSpecificationNotes
In nitrogen, air, CO2 or methane0 to 100 %, 0 to 3 % or 97 to 100 %
In argon0 to 100 %, 0 to 3 % or 97 to 100 %
In helium20 to 100 %, 20 to 40 % or 85 to 100 %
In oxygen0 to 100 %, 0 to 4 % or 97 to 100 %
Resolution0.01 %
RepeatabilityBelow 1 % of full scaleLinearity below 1 % of range
Response timeT90 below 10 s at 0.6 LPM
Sample flow0.6 LPM recommended
Sample temperature5 to 45 C
Power100 to 240 V AC, 50/60 Hz, 45 W
OutputIsolated 4-20 mA, user-programmable range; Modbus RTU over RS 485Programmable relays for alarms, fault, pump or range ID, calibration

From the current Sarvesh product datasheets and company profile. Specifications may change without notice as products improve. The final responsibility to check that a product meets the process and analyser requirement remains with the customer.

Key features

  • Dual-level password protection and history of alarms and calibrations
  • Programmable alarms Lo-Hi, Lo-Lo, Hi-Hi
  • Output freeze or follow during calibration

How it works

Hydrogen has the highest thermal conductivity of any gas, so a thermal conductivity sensor responds strongly to it. Platinum-based sensing avoids the need for a reference gas and holds calibration well.

Typical uses are hydrogen production and filling, hydrogen purity in cooling of generators, metal processing and heat treatment atmospheres, and leak detection in safe-area enclosures. Response is fast, with T90 below 10 seconds at the recommended 0.6 LPM.

Requirements and limits

  • Safe-area analyser; a single known background gas assumed.

On site: utilities and calibration gases

What to have ready at your plant before installation and commissioning.

ItemRequirementNotes
Power at the analyser100 to 240 V AC, 50/60 Hz, 45 W
Zero gasZero-grade nitrogen, 99.999 %10 litre cylinder with regulator
Span gasThe measured gas at zero grade, 99.999 %: hydrogen, helium, argon or nitrous oxide10 litre cylinder with regulator
Sample at the analyser2 to 10 psig, 0.6 LPM, 5 to 40 °C, dust below 3 micronPressure and flow regulated by the user
Mounting19 inch rack or panel, in a safe area

Selection guidance

Choose ACCURRA-TCD for hydrogen in one known background gas in a safe area. For classified areas choose ACCURRA-Hz.

Applications

Application pages where this is part of the recommended solution:

Compatible products

Frequently asked questions

What range does it cover?

0 to 100 percent hydrogen, or narrow ranges such as 0 to 3 or 97 to 100 percent; the ranges depend on the background gas.

Which backgrounds?

One of nitrogen, air, CO2, methane, argon, helium or oxygen.

Does it need a reference gas?

No.

Can I use it in a hazardous area?

Use ACCURRA-Hz.

Talk to an applications engineer

Send the gas, range, pressure, temperature and area classification.