ACCURRA-S measures carbon monoxide from 0 to 1000 ppm with an electrochemical cell (model 2015) and from 0 to 100 % with NDIR (model 2030, ranges down to 0 to 5 %). It can be paired with CO2 or oxygen in a dual-gas enclosure.
Specifications
| Item | Specification | Notes |
|---|---|---|
| 2015 | 0 to 1000 ppm (min 0 to 100 ppm) | Electrochemical cell, sensor life above 2 years; accuracy 1 % of FS; T90 below 30 s |
| 2030 | 0 to 100 % (min 0 to 5 %) | NDIR, sensor life above 5 years; accuracy 2 % of FS; T90 below 30 s |
| Dual-gas pairings | CO ppm with O2 ppm or %; CO ppm with CO2 ppm or %; CO % with CO2 %; CO % with O2 % | Independent outputs and Modbus IDs |
From the current Sarvesh product datasheets and company profile. Specifications may change without notice as products improve. The final responsibility to check that a product meets the process and analyser requirement remains with the customer.
Key features
- Failsafe alarm relays, configurable as Lo-LoLo, Lo-Hi or Hi-HiHi
- Dual-range 4-20 mA with range ID relay
- Calibration history with deviation values and password protection
How it works
Carbon monoxide is both a hazard and a process signal. In combustion, a rising CO reading says air is short. In steel, syngas and heat treatment atmospheres, CO is a main component. In gas certification, a few ppm of CO is an impurity limit.
Electrochemical cells are sensitive and economical at ppm level but respond to other gases and have a finite life. NDIR measures percent levels directly and is stable for years. ACCURRA-S uses the one that suits your range.
Requirements and limits
- Safe-area analyser. Sample should be non-corrosive, non-toxic, non-flammable and dry per the catalogue, so high-CO streams are reviewed individually.
- INFINITY-Tx measures trace CO in hazardous areas.
On site: utilities and calibration gases
What to have ready at your plant before installation and commissioning.
| Item | Requirement | Notes |
|---|---|---|
| Power at the analyser | 100 to 240 V AC, 50/60 Hz, 45 W | |
| Zero gas | Zero-grade nitrogen, 99.9999 % | 10 litre cylinder with regulator |
| Span gas, percent CO | Zero-grade CO, 99.999 % | 10 litre cylinder with regulator |
| Sample at the analyser | 2 to 10 psig, about 1 LPM, 5 to 45 °C, dust below 3 micron | Pressure and flow regulated by the user |
| Mounting | 19 inch rack or panel, in a safe area |
Selection guidance
Choose 2015 for ppm CO impurity checks in nitrogen, argon and helium, and for combustion safety. Choose 2030 for percent CO in process gas, furnace atmospheres and test ducts.
Carbon monoxide is toxic, and the standard sample specification excludes toxic samples; we review streams with significant CO case by case and design the venting.
Applications
Application pages where this is part of the recommended solution:
- Gas purity certification and cylinder filling
- Heat-treatment furnace atmosphere
- Steel plant process gases
- Pyrolysis, gasification and syngas
- Optical fibre and cable manufacturing
Compatible products

ACCURRA-S
Online analyser for trace, percent and purity O2, CO, CO2, CH4 and dew point; can measure two gases from one sample.
View ACCURRA-S
ACCURRA-Hz
Process gas analyser in an enclosure certified for Gas Group IIC, Zone 1 and 2, T6.
View ACCURRA-Hz
INFINITY-Tx
Loop-powered two-wire transmitter for percent O2 and trace CO in hazardous areas.
View INFINITY-Tx
SP and SRP sample probes
Heated and non-heated probes with blowback, and retractable probes, in SS316, Inconel or ceramic.
View SP and SRP sample probesFrequently asked questions
Which model for ppm CO?
Model 2015, 0 to 1000 ppm, electrochemical.
Which model for percent CO?
Model 2030, 0 to 100 percent with ranges down to 0 to 5 percent, NDIR.
Can I measure CO and CO2 together?
Yes, in a dual-gas ACCURRA-S, in ppm or percent.
Can I measure CO in a hazardous area?
INFINITY-Tx measures trace CO as a loop-powered transmitter, and ACCURRA-Hz measures CO from ppm to percent.