Gas Group IIC · Zone 1 and 2 · T6

ACCURRA-Hz gas analysers for hazardous areas

Oxygen from ppm to purity, carbon monoxide, methane and hydrogen, measured inside the classified area in a flameproof enclosure certified to IS/IEC 60079-1:2014. Calibrate without opening the covers, or operate the analyser remotely with ACCURRA-CONNECT.

ACCURRA-HzACCURRA-Hz
  • ISO 9001:2015, certified by TÜV
  • Designed and built in Pune since 2002
  • Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO
Quick answer

ACCURRA-Hz measures trace oxygen, CO and CO2, and percent or purity of CO, CO2 and hydrogen in an enclosure certified for Gas Group IIC, Zone 1 and 2, T6 (IS/IEC 60079-1:2014). Calibration is possible without opening the covers. Ask for current certificate copies.

Updated 3 November 2026 · Figures from Sarvesh datasheets

Why ACCURRA-Hz

Calibrate with the covers closed

Calibration is done without opening the flameproof enclosure, and is tamper-proof, with separate passwords for user and manager.

Operate from outside the area

Optional ACCURRA-CONNECT software runs every function over Modbus from a PC, where movement in the hazardous area is restricted.

The ACCURRA platform, certified

Dual-range 4–20 mA, failsafe relays, Modbus RTU and calibration history, in a wall-mounted IP 66 enclosure.

Specifications

ItemSpecificationNotes
Oxygen0 to 100 or 1000 ppm; 0 to 25 %; 0 to 100 % or 95 to 100 %Models 3015, 3030, 3090, 3130 and 3190; electrochemical or paramagnetic
Carbon monoxide0 to 2000 ppm (electrochemical, 2015); 0 to 100 % (NDIR, 2030)
Methane0 to 100 % (NDIR, 4030)
Hydrogen0 to 100 % in nitrogen (thermal conductivity, 1030)T90 below 10 s at 0.6 LPM; other backgrounds on request
Oxygen purityAmbient pressure and temperature compensatedError below 0.5 % on 3090 and 3190
EnclosureWall mounted, 410 H x 370 W x 245 D mm, IP 66, about 12 kgGas Group IIC, Zone 1 and 2, T6 as per IS/IEC 60079-1:2014; confirm current certificate validity
Power24 V DC, 30 W, or 100 to 240 V AC, 50/60 Hz, 45 W
OutputsIsolated 4-20 mA, dual range, max load 500 ohm; 4 failsafe SPST relaysTwo alarms, fault, sample pump or range ID; Modbus RTU over RS 485
CalibrationWithout opening the covers; tamper-proof
SiblingINFINITY-Tx two-wire transmitterPercent O2, trace CO

From the current Sarvesh product datasheets and company profile. Specifications may change without notice as products improve. The final responsibility to check that a product meets the process and analyser requirement remains with the customer.

Key features

  • Enclosure certified for Gas Group IIC, Zone 1 and 2, T6
  • Calibration possible without opening covers, and tamper-proof
  • Separate passwords for user and manager; separate hardware diagnostics menu
  • Purity oxygen with ambient pressure and temperature compensation
  • Optional ACCURRA-CONNECT PC software operates the analyser remotely over Modbus, as if you were standing at it, where movement in the hazardous area is restricted
  • Optional auto-calibration with external solenoid valves, started from the keypad, a cyclic timer or Modbus (not on 3015)
  • Available panel-mounted with its sampling system

How it works

Hydrogenation, electrolysis, reactors and solvent areas are classified because flammable gas or vapour may be present. An analyser in such an area must not be a source of ignition, so its electronics go in a certified flameproof enclosure.

The usual difficulty with flameproof analysers is calibration, since opening the cover normally needs the area made safe. ACCURRA-Hz allows calibration without opening the covers.

Confirm your area classification, gas group and temperature class when you enquire, and ask us for current certificate copies. We make no SIL claim for these analysers; if your project requires one, tell us at the start.

Requirements and limits

  • Certificate validity and scope should be confirmed against your project requirement before ordering.
  • No SIL claim is made.

On site: utilities and calibration gases

What to have ready at your plant before installation and commissioning.

ItemRequirementNotes
Power at the analyser24 V DC, 30 W, or 230 V AC
Zero gasZero-grade nitrogen, 99.9999 %10 litre cylinder with regulator
Span gas, trace oxygen1000 ppm oxygen in nitrogen10 litre cylinder with regulator
Span gas, 3090Zero-grade oxygen; zero on zero-grade nitrogen
Span gas, 3190Zero-grade oxygen; zero on 95 % oxygen in nitrogen
Instrument air and service nitrogen4 kg/cm² minimum
MountingWall mounted in the classified areaCalibration without opening the covers

Selection guidance

Choose ACCURRA-Hz for hydrogenation, electrolysis, petrochemical, solvent and gas-house applications. For percent oxygen in a field-mounted two-wire form, see INFINITY-Tx.

Applications

Application pages where this is part of the recommended solution:

Compatible products

Frequently asked questions

What area classification does ACCURRA-Hz meet?

Gas Group IIC, Zone 1 and 2, T6, as per IS/IEC 60079-1:2014. Ask us for current certificate copies.

Can I calibrate in the field?

Yes, without opening the covers.

Does it have a SIL rating?

We make no SIL claim.

Which gases can it measure?

Oxygen from ppm to purity, carbon monoxide from ppm to percent, methane and hydrogen.

Can I operate it remotely?

Yes, with the optional ACCURRA-CONNECT PC software over Modbus.

Talk to an applications engineer

Send the gas, range, pressure, temperature and area classification.