Learn · Learning path
Keep analysers running
Calibrate with confidence, diagnose quickly and plan maintenance before readings drift.
What you will be able to do
- Calibrate correctly and know what the adjustment did
- Choose and handle calibration gas without introducing error
- Set a calibration interval you can defend
- Diagnose a reading that is high, low, noisy, slow or stuck
- Plan spares and sensor replacement
Your progress: 0 of 9 lessons read
Follow these lessons in order
- Accuracy, precision, repeatability and drift in gas analysersAccuracy is how close a reading is to the true value; precision or repeatability is how closely repeated readings agree; drift is how the reading moves over time.Know what drift is before fighting it.Intermediate3 min
- How gas analyser calibration works: zero and spanCalibration compares the analyser's reading with a gas of known concentration and adjusts it to match.Zero and span, properly.Beginner4 min
- Calibration gases: choosing, handling and certificatesChoose span gas near 70 to 90 % of the range in a balance gas that matches the sample, with a certificate stating concentration, uncertainty and expiry.Bad gas makes a bad calibration.Intermediate3 min
- How often should you calibrate a gas analyser?Set the interval from three things: how much error the process can tolerate, how fast the analyser drifts, and what a wrong reading costs.A risk-based interval.Intermediate3 min
- Auto-Calibration and validation checks for gas analysersAuto-calibration switches zero and span gas to the analyser by solenoid valves on a timer, keypad or Modbus command, and adjusts or records the result.What to automate and what not to.Intermediate3 min
- Troubleshooting gas analyser readings: high, low, noisy, slowApply known gas at the analyser inlet.Symptoms to causes.Intermediate3 min
- Sample system troubleshooting: symptoms to causesMost analyser faults are sample system faults.Most faults are in the sample.Intermediate3 min
- Sensor life, poisoning and replacement in gas analysersElectrochemical cells are consumed by the gas they measure and last months to years depending on exposure.Know the end of life.Intermediate3 min
- Maintenance schedule and spares for gas analysersMaintain analysers by routine: a daily look at flow, pressure and condensate; a weekly check of filters and drain; a monthly calibration check; and an annual full calibration, sensor check and leak test.Put it on a schedule.Intermediate3 min
Stuck on a real problem while you learn? Ask an engineer. Every lesson is checked against the figures in our catalogues.