ACCURRA-S models 6015 and 6030

Online carbon dioxide (CO2) analyser with NDIR sensor

ACCURRA-S measures carbon dioxide by non-dispersive infrared, from 0 to 5000 ppm on 6015 and 0 to 20 or 0 to 100 percent on 6030. Both come with a sensor life above five years.

ACCURRA-S carbon dioxide analysers
  • ISO 9001:2015, certified by TÜV
  • Designed and built in Pune since 2002
  • Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO
Quick answer

ACCURRA-S measures CO2 by NDIR, from 0 to 5000 ppm (model 6015) and from 0 to 20 % or 0 to 100 % (model 6030), with a sensor life above five years. Dual-gas versions pair CO2 with oxygen, CO or methane.

Updated 3 November 2026 · Figures from Sarvesh datasheets

Specifications

ItemSpecificationNotes
60150 to 5000 ppm (min 0 to 100 ppm)NDIR, sensor life above 5 years; accuracy 1 % of FS; T90 below 60 s
60300 to 20 % or 0 to 100 % (min 0 to 5 %)NDIR, sensor life above 5 years; accuracy +/- 1 % of FS; T90 below 60 s
Dual-gas pairingsCO2 with O2 (ppm or %), CO2 with CO (ppm or %), CO2 with CH4 (%)Independent outputs

From the current Sarvesh product datasheets and company profile. Specifications may change without notice as products improve. The final responsibility to check that a product meets the process and analyser requirement remains with the customer.

Key features

  • NDIR is stable and needs infrequent calibration
  • Calibration check and history; optional auto-calibration
  • Output freeze during calibration

How it works

NDIR sensors measure how much infrared light a gas absorbs at a wavelength specific to it. Carbon dioxide absorbs strongly, so it is measured accurately and stably for years, with little drift compared with electrochemical cells.

CO2 is measured as an impurity in nitrogen and argon, as a product in fermentation and combustion, as a component of biogas and welding blends, and as the product in beverage and dry ice plants.

Requirements and limits

  • Safe-area analyser; the sample should be dry and free from oil and condensate.

On site: utilities and calibration gases

What to have ready at your plant before installation and commissioning.

ItemRequirementNotes
Power at the analyser100 to 240 V AC, 50/60 Hz, 45 W
Zero gasZero-grade nitrogen, 99.9999 %10 litre cylinder with regulator
Span gas, percent CO₂Zero-grade CO₂, 99.999 %10 litre cylinder with regulator
Sample at the analyser2 to 10 psig, about 1 LPM, 5 to 45 °C, dust below 3 micronPressure and flow regulated by the user
Mounting19 inch rack or panel, in a safe area

Selection guidance

Choose 6015 for ppm-level CO2 impurity. Choose 6030 for percent CO2 in fermenter off-gas, welding blends, biogas and furnace atmospheres.

For CO2 and CH4 together see the dual-gas biogas analyser page.

Applications

Application pages where this is part of the recommended solution:

Compatible products

Frequently asked questions

What ranges are available?

0 to 5000 ppm on 6015, and 0 to 20 or 0 to 100 percent on 6030.

Is CO2 affected by moisture?

The sample should be dry and non-condensing; use a cooler and filter for wet samples.

Can I read CO2 with oxygen?

Yes, in a dual-gas ACCURRA-S.

How long does the sensor last?

The catalogue gives more than five years.