Steel, heat treatment and furnaces

Oxygen and dew point analyser for aluminium controlled-atmosphere brazing

CAB lines need very low oxygen and dew point in the nitrogen atmosphere; a dual analyser reads both from one tapping. Sarvesh supplies ACCURRA-S 3015, M015, built in Pune, with sampling matched to the stream.

  • ISO 9001:2015, certified by TÜV
  • Designed and built in Pune since 2002
  • Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO
Quick answer

Use ACCURRA-S 3015 + M015 (dual-channel, one sample). CAB lines need very low oxygen and dew point in the nitrogen atmosphere; a dual analyser reads both from one tapping. Furnace OEMs supply the atmosphere design; engage them as a channel.

Updated 2 November 2026 · Figures from Sarvesh datasheets

The measurement and why it matters

CAB lines need very low oxygen and dew point in the nitrogen atmosphere; a dual analyser reads both from one tapping. This application matches the catalogue specification directly.

In furnaces, chambers and dry rooms the atmosphere is part of the recipe. A few ppm of oxygen, a dew point or a hydrogen share decides surface finish, yield or safety, and a leak or a drifting gas supply shows up in the analyser before it shows up in the product.

These atmospheres are usually clean at the analyser but can be hot, sooty or particulate-laden at the furnace take-off. Sample from the right point, keep lines short and use dry stainless tubing. Tell us the furnace or chamber volume and flow so we can confirm the sample path.

Typical buyers in India: radiator and heat-exchanger makers (automotive), CAB furnace OEMs. Where this matches your plant, send us the gas, range, pressure and temperature at the tapping point and we will confirm the analyser and sample path.

Models and ranges

ModelMeasuresRangeSensor and notes
3015Trace oxygen0 to 1000 ppm (min range 0 to 100 ppm)Electrochemical; no internal pump, no auto-calibration
M015Dew point-80 to +20 CCeramic sensor; no internal pump, no auto-calibration

Process notes

What the analyser reads here

Gases of interest: O2 ppm + dew point. Analyser fit: ACCURRA-S 3015 + M015 (dual-channel, one sample).

The table above lists each model with its range; where a row says to confirm the range, we check it against the datasheet for your application before quoting.

What to settle before ordering

Furnace OEMs supply the atmosphere design; engage them as a channel.

We would rather confirm these points at the start than discover them at commissioning, so please include them with your process details.

Sampling and installation

  • Every ACCURRA-S has an internal fine filter and rotameter. Regulate sample pressure and flow externally; the catalogue recommends about 1 LPM and a sample pressure of 2 to 10 psig.
  • Models 3015, M015, 3130 and 3190 are supplied without an internal sample pump. Tell us the sample pressure and we will confirm the sample path or add a pump.
  • Models 3015 and M015 have no auto-calibration, so plan a calibration routine with the right reference gas.
  • Keep sample lines short, clean and dry, and vent the sample somewhere safe.

ACCURRA-S sample specification: non-corrosive, non-toxic, non-flammable, non-condensing and dry, free from entrained oil; sample pressure 2 to 10 psig, regulated externally; flow about 1 LPM; dust below 3 micron. Where your sample differs, we design conditioning around it.

Send us your process data

Application data sheet

The same pre-order design inputs our engineers design from, online. Fill in what you know, leave the rest. Your draft saves as you go, and you can print or send it when ready.

Start the data sheet
What the data sheet asks for

Send what you have and we will ask for the rest.

  • The gases to measure, the range, and the accuracy you need
  • Background gases and their typical composition
  • Sample temperature, pressure and dew point at the tapping point
  • Dust level, and whether the gas carries tar, oil or condensable vapour
  • Process connection and, for ducts, the duct diameter
  • Where the sample vents to, and at what pressure
  • Area classification of the tapping point and of the analyser location, and the IP protection needed
  • Distance between the tapping point and the analyser
  • Outputs you need: 4-20 mA, dual range, relays, Modbus RTU
  • Calibration approach, calibration gas available, and whether blowback is required
  • Utilities at site: power supply, instrument air, nitrogen, steam and cooling water, and the ambient temperature range
  • Gases and ranges: O2 ppm + dew point
  • The point to confirm: Furnace OEMs supply the atmosphere design; engage them as a channel.

Frequently asked questions

Which analyser suits aluminium controlled-atmosphere brazing furnaces?

ACCURRA-S 3015 + M015 (dual-channel, one sample) CAB lines need very low oxygen and dew point in the nitrogen atmosphere; a dual analyser reads both from one tapping.

What should I check before ordering for aluminium controlled-atmosphere brazing furnaces?

Furnace OEMs supply the atmosphere design; engage them as a channel.

Who typically needs this?

Typical buyers in India: radiator and heat-exchanger makers (automotive), CAB furnace OEMs.

Can Sarvesh support a variation of this application?

Yes. If your process differs from the usual case, send the details. Application engineering is where we start every project, and bespoke applications are welcome.

Further reading

More in Steel, heat treatment and furnaces

Talk to an applications engineer

Send the gas, range, pressure, temperature and area classification.

Request a quoteStart the application data sheetOur pre-order design inputs, online+91 94 2300 4179Sales; support +91 94 2300 4178