Accurate gas analysis. Built for uptime.
Online gas analysers and the sample handling that keeps them honest. Designed, built and supported from our own factory in Pune, for plants where the reading has to be right.
I need to measure
The reading is only as good as the sample that reaches the sensor.
Most analyser trouble starts upstream of the analyser. We design and build every stage of the path, so there is one team to call.

Extract a representative sample
Sample probes in SS316, Inconel and ceramic, with a separate blowback line and heated filters for tarry gas. The retractable SRP-400 lets you service the probe under process pressure, without a shutdown.

Cool, dry and supervise the sample
i-Cons puts the pump, Peltier cooler, filter, condensate and flow sensors, blowback and heated-line control in one cabinet, and warns before a fault becomes a wrong reading. Vaporisers handle cryogenic and wet samples.
Protect the analyser
We are the exclusive Indian representative of Headline Filters, UK: particulate, coalescing and PTFE membrane elements and housings, up to 700 bar and 500 °C, to keep dust, liquid and oil away from analysers, valves and regulators.



Measure with the right method
ACCURRA-S for oxygen, CO, CO₂, methane and moisture. ACCURRA-TCD for hydrogen, helium and argon, with no reference gas. ACCURRA-Hz and INFINITY-Tx for hazardous areas, and ACCURRA-Zr in the flue duct.
Deliver data you can trust
Isolated, user-ranged 4–20 mA outputs, failsafe alarm relays, Modbus RTU and stored calibration and alarm history, so the reading reaches your control system with a record of how it was made.
Every part of the measurement, from one maker.
The analyser and the sample system that feeds it are designed by the same engineers, so they work as one measurement. Pick a family for ranges, performance and datasheets.
Safe areaACCURRA-SO₂, CO, CO₂, CH₄ and dew point, from ppm to purity. Two gases in one enclosure if you need them.Trace to 100 %Dual gasModbus RTU- Safe area · Binary gasACCURRA-TCDH₂, He, Ar, N₂ and N₂O by thermal conductivity, with no sealed reference and no reference gas.T90 below 10 sDrift below 1 %/week
Hazardous areaACCURRA-HzO₂, CO, CH₄ and H₂ in classified areas, calibrated without opening the covers.IIC, Zone 1 and 2, T6Remote operation
Flue gasACCURRA-ZrZirconia oxygen for boilers and furnaces, with the sensor protected outside the duct.0.1 to 21 % O₂Air calibrationAuto blowback
Hazardous area · FieldINFINITY-TxTwo-wire, loop-powered transmitter for percent O₂ and trace CO, mounted at the process.Loop poweredLow-flow samples
Sample handlingi-Cons and samplingSmart Peltier conditioner, coolers, probes, vaporisers and Headline filters for a sample you can trust.Plug and playModbus diagnostics
All products and specificationsNot sure which? Use the analyser selectorDatasheets
Plants and institutions that rely on Sarvesh.

Indian Oil Corporation
Hindustan Petroleum

Department of Atomic Energy
Bosch
Sun Pharmaceutical
Grasim Industries

Manipal Institute of TechnologySteel Authority of India
Hindalco Industries
Air Liquide
Tata Power

Bharat Petroleum
Indian Space Research Organisation
Nuclear Power Corporation of India

NTPC (Aravali Power)
IIT Bombay
GAIL (India)

Mangalore Refinery and Petrochemicals
Bhabha Atomic Research Centre


ITC
Indian Institute of Science
A selection of the organisations we have supplied. See more.
Built for the processes that cannot afford a wrong number.
Each application page gives the measurement, the analyser and range, and the sampling it needs. If yours is not listed, send us the process details: we also engineer bespoke applications.
- Air separation and industrial gasesOxygen purity in air separation plants · Medical oxygen plant purity monitoring · Nitrogen purity and trace oxygen · Dew point and trace moisture in process gases
- Hydrogen and new energyHydrogen purity · Electrolyser safety and quality · Biogas and compressed biogas (CBG) · Chlor-alkali hydrogen stream: oxygen in hydrogen
- Power, boilers and emissionsBoiler and furnace oxygen (flue gas) · Stack and emission monitoring · Thermal oxidiser and scrubber efficiency · Cement kiln and precalciner O2 and CO
- Steel, heat treatment and furnacesHeat-treatment furnace atmosphere · Steel plant process gases · Float glass bath atmosphere · Cold rolling mill furnaces
- Pharma, chemicals and petrochemicalsNitrogen blanketing and inerting · Reactors, hydrogenation and polymerisation · Closed-loop dryers and spray dryers · Fermenter and bioreactor off-gas
- Electronics, cable and researchSemiconductor and electronics gas purity · Optical fibre and cable manufacturing · Welding and laser gas mixtures · Aerospace, nuclear and research laboratories
- Food, agriculture and cold chainControlled-atmosphere (CA and ULO) fruit stores · Fruit ripening rooms · Modified-atmosphere packaging gas mixer verification · Nitrogen supply purity for food and beverage packaging
From the first drawing to the thousandth hour of uptime.
Concept to Commissioning
We start with your process and your sample, then engineer the analyser and sampling system around them, supply it, and see it through commissioning.
System Health Management
After handover our focus stays on support and product health, so the measurement keeps doing its job for the life of the plant.
Get to the right answer faster.
Find your analyser
Choose the gas, range, area classification and sample conditions. The selector returns an indicative model and sampling arrangement from our datasheets.
Open the selector →Application data sheet
The design inputs our engineers work from, online: up to four measurement points, checks as you type, and a printable summary.
Start the data sheet →- Why ambient pressure and temperature change high-purity oxygen readingsMany oxygen sensors respond to the partial pressure of oxygen, which falls when barometric pressure falls even if the gas is unchanged.
- What is dew point, and how is it measured in dry gas?Dew point is the temperature at which moisture in a gas begins to condense.
- How to design a gas sample handling system for an online analyserA good sample handling system delivers a representative, clean, dry sample at constant pressure and flow.
Tell us the gas, the range and the process.
We will recommend the analyser and the sampling system that fit, and tell you straight if something else fits better.