Sarvesh makes the sample handling between process and analyser: probes (SP-100, SP-200, SP-300, SRP-400), the SGI-300 Peltier cooler, i-Cons and SGI-320 systems, SV-200 and SV-400 vaporisers, and, as exclusive India representative, Headline Filters from the UK.
Specifications
| Item | Specification | Notes |
|---|---|---|
| Probes | SP-100, SP-200, SP-300, SRP-400 | |
| Cooler | SGI-300 Peltier sample cooler | |
| Complete system | i-Cons smart sample conditioner; SGI-320 emission monitoring system | |
| Vaporisers | SV-200 cryogenic, SV-400 wet-sample | |
| Filters | Headline Filters, UK | Exclusive representative for India |
From the current Sarvesh product datasheets and company profile. Specifications may change without notice as products improve. The final responsibility to check that a product meets the process and analyser requirement remains with the customer.
Key features
- One supplier for the whole measurement path
- Compact, plug-and-play designs that cut tubing, wiring and panel space
- Diagnostics, blowback control and early warnings in i-Cons and SGI-320
How it works
Most analyser problems begin upstream of the analyser: a blocked probe filter, condensate in the line, a pump that has quietly failed. The sample handling system is the key to years of accurate measurement, and ACCURRA-S expects a sample that is non-corrosive, non-toxic, non-flammable, dry and free of oil, at 2 to 10 psig and about 1 LPM.
Where your sample does not meet that, we design the conditioning around your application. A typical chain has a probe with a filter, a transport line, a cooler or vaporiser, a pump, fine filters and scrubbers, and the analyser. Sarvesh makes each element, and combines them in i-Cons and SGI-320 so that they are controlled by one microcontroller.
Requirements and limits
- i-Cons and SGI-320: not suitable for samples containing HCl, HF, H2S or other highly corrosive, toxic or flammable gases.
Selection guidance
Choose the probe from the gas temperature and dust, the conditioner from the sample dew point and composition, and filters from what must be removed. Send our pre-order input sheet details and we will propose a system.
Applications
Application pages where this is part of the recommended solution:
- Stack and emission monitoring
- Steel plant process gases
- Pyrolysis, gasification and syngas
- Fermenter and bioreactor off-gas
Compatible products
i-Cons
Smart Peltier sample conditioner with diagnostics, auto blowback and Modbus, in a compact 19 inch cabinet.
View i-Cons
SGI-300 / SGI-320
Peltier sample cooler with integrated pump, filter and condensate detector; SGI-320 for emission monitoring.
View SGI-300 / SGI-320
SP and SRP sample probes
Heated and non-heated probes with blowback, and retractable probes, in SS316, Inconel or ceramic.
View SP and SRP sample probesSV-200 / SV-400 vaporisers
Sample vaporisers for cryogenic and wet samples with no loss of sample.
View SV-200 / SV-400 vaporisersHeadline filters
Particulate, coalescing and PTFE membrane filters from Headline Filters, UK, for analyser protection.
View Headline filtersFrequently asked questions
Do I need a sampling system?
Clean, dry, non-corrosive, non-flammable samples at 2 to 10 psig can go straight to ACCURRA-S through its fine filter. Hot, wet or dusty samples need conditioning.
Can you design a system for my process?
Yes. Send the sample temperature, pressure, dew point, dust level and distance to the analyser.
Do you make filters?
We are the exclusive representative of Headline Filters Ltd., UK, and make our own filter housings, catchpots and scrubbers.
What is a heated line for?
To keep the sample above its dew point between the probe and the conditioner.