ACCURRA-S dual channel

Dual-gas O2 and CO2 analyser in percent for fermenters and blends

A dual-gas ACCURRA-S measures percent oxygen and percent CO2 in one enclosure, for fermenter off-gas, gas blends and process gas.

Dual gas O2 and CO2 (percent)
  • ISO 9001:2015, certified by TÜV
  • Designed and built in Pune since 2002
  • Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO
Quick answer

A dual-gas ACCURRA-S measures percent oxygen and percent CO2 in one enclosure, for example 3030 plus 6030 for fermenter off-gas. Independent outputs and Modbus IDs let a control system calculate uptake and evolution rates and the respiratory quotient.

Updated 3 November 2026 · Figures from Sarvesh datasheets

Specifications

ItemSpecificationNotes
O20 to 25 % or 0 to 100 %Electrochemical 3030 or paramagnetic 3130
CO20 to 20 % or 0 to 100 %NDIR 6030
IndependenceOwn electronics, outputs, relays and Modbus ID per channel

From the current Sarvesh product datasheets and company profile. Specifications may change without notice as products improve. The final responsibility to check that a product meets the process and analyser requirement remains with the customer.

Key features

  • Independent electronics, microcontroller, 4-20 mA, relays and Modbus ID per sensor
  • Common pneumatics and one fine filter
  • Calibration history and password protection

How it works

Oxygen and carbon dioxide together describe respiration, combustion and blending. In a fermenter their changes give oxygen uptake rate, carbon dioxide evolution rate and respiratory quotient. In a welding blend they describe the composition. In combustion, oxygen consumed and CO2 produced show fuel and air balance.

The catalogue combination is O2 percent with CO2 percent in argon or nitrogen, and the pharma application note recommends 3030 plus 6030 for bioreactor off-gas.

Requirements and limits

  • Safe-area analyser; the standard sample specification applies.

Selection guidance

See the dual-gas analyser page for the full list of combinations.

Applications

Application pages where this is part of the recommended solution:

Compatible products

Frequently asked questions

What ranges?

Oxygen 0 to 25 or 100 percent, CO2 0 to 20 or 100 percent.

Which models for a fermenter?

3030 for oxygen and 6030 for CO2.

Do the channels interfere?

No. Each has its own electronics.

Can I calculate respiratory quotient?

Yes, from the two Modbus readings.

Talk to an applications engineer

Send the gas, range, pressure, temperature and area classification.

Request a quoteDownload the datasheetGas analysers datasheets, PDF 4.8 MB+91 94 2300 4179Sales; support +91 94 2300 4178
Request a quote Call sales