Headline's chart gives a comparable Headline housing for most Balston housings: the Balston 95S6-1/4" compares with the Headline 122, the 92 1/4 with the 360 1/4", and the A93 with the 315. Check the rating of the Headline model against your duty; we confirm it before quoting.
Comparable housings
Each Headline model links to its ports and rating. Compare the rating with your duty before changing a housing.
Membrane & Plastic Housings
| Balston model | Comparable Headline model | Type |
|---|---|---|
| 98-0 | GMS105-1/4"-M1 | Membrane Housings |
| 58P | 755N 1/4" | Plastic Housings |
| 98014 | MT.33.M1 | Membrane Housings |
| 58N | 760N 1/2" | Plastic Housings |
| 98-2 | GMS105-1/4"-M2 | Membrane Housings |
| 84-700 | 710N 1/4" | Plastic Housings |
| 98015 | MT.33.M2 | Membrane Housings |
| 53/18 | 718 | Plastic Housings |
| A98-0 | GMS122.M1 | Membrane Housings |
| 53/50 | 720B | Plastic Housings |
| 98002 | MT.33.M1 | Membrane Housings |
| 54/50 | 720 | Plastic Housings |
| 98010 | MT.33.M1/50C | Membrane Housings |
| 53/95 | 795B | Plastic Housings |
| A98-2 | GMS122.M2 | Membrane Housings |
| 98020 | MT.33.M2 | Membrane Housings |
| 98012 | MT.33.M2/50C | Membrane Housings |
| A39 / 12-0 | GMS132.M1 | Membrane Housings |
| 39014 | MT.61.M1 | Membrane Housings |
| A39 -12-2 | GMS132.M2 | Membrane Housings |
| 39015 | MT.61.M2 | Membrane Housings |
| 150-12-DQ | 38-64-70C | Membrane Housings |
| 150-12-BQ | 38-64-50C | Membrane Housings |
Aluminium & Stainless Steel Housings
| Balston model | Comparable Headline model | Type |
|---|---|---|
| 95A | 210AL | Compressed Air (Aluminium) |
| 105S6 | 110 | Gas Analysis (Stainless Steel) |
| A944 | 710N | Compressed Air (Aluminium) |
| A93, A94 | 315 | Compressed Air (Aluminium) |
| A93A | 315A | Compressed Air (Aluminium) |
| 91S6-1/8" | 120 | Gas Analysis (Stainless Steel) |
| A94A | 315A | Compressed Air (Aluminium) |
| 91S6-1/4" | 122 | Gas Analysis (Stainless Steel) |
| 92 1/4 | 360 1/4" | Compressed Air (Aluminium) |
| 95S6-1/8" | 120 | Gas Analysis (Stainless Steel) |
| 92 1/2 | 365 1/2" | Compressed Air (Aluminium) |
| 95S6-1/4" | 122 | Gas Analysis (Stainless Steel) |
| 92A 1/4 | 360A 1/4" | Compressed Air (Aluminium) |
| 47S6 | 122B4 | Gas Analysis (Stainless Steel) |
| 92A 1/2 | 365A 1/2" | Compressed Air (Aluminium) |
| 92810 1/4 | 360 1/4" | Compressed Air (Aluminium) |
| 92810A 1/4 | 360A 1/4" | Compressed Air (Aluminium) |
| 85 | 122LB | Gas Analysis (Stainless Steel) |
| 92812 1/2 | 365 1/2" | Compressed Air (Aluminium) |
| 97S6 | 116IL | Gas Analysis (Stainless Steel) |
| 92812A 1/2 | 365A 1/2" | Compressed Air (Aluminium) |
| 30/12 | 136IL | Gas Analysis (Stainless Steel) |
| 92/25A | 370A | Compressed Air (Aluminium) |
| 30/25 | 146IL | Gas Analysis (Stainless Steel) |
| A62A Series | 380AHP | Compressed Air (Aluminium) |
| 31S6-1/4" | 137 | Gas Analysis (Stainless Steel) |
| A60A | 385AHP | Compressed Air (Aluminium) |
| 31S6-1/2" | 138 | Gas Analysis (Stainless Steel) |
| A912A | 360AF 1/4" | Compressed Air (Aluminium) |
| 31G-1/4" | 137G | Gas Analysis (Stainless Steel) |
| A912 | 360F 1/4" | Compressed Air (Aluminium) |
| 31G-1/2" | 138G | Gas Analysis (Stainless Steel) |
| A913A | 365AF 1/2" | Compressed Air (Aluminium) |
| 33S6-1/4" | 137 or 130 | Gas Analysis (Stainless Steel) |
| A913 | 365F 1/2" | Compressed Air (Aluminium) |
| A915A | 370AFI | Compressed Air (Aluminium) |
| 33G-1/4" | 137G | Gas Analysis (Stainless Steel) |
| A917A | 370A-AD | Compressed Air (Aluminium) |
| 33G-1/2" | 138G | Gas Analysis (Stainless Steel) |
| A962 | 380AHPFVDI-1" | Compressed Air (Aluminium) |
| 41S6-1/4" | 147 or 140 | Gas Analysis (Stainless Steel) |
| A963 | 380AHPFVDI-3/4" | Compressed Air (Aluminium) |
| 41S6-1/2" | 148 or 142 | Gas Analysis (Stainless Steel) |
| A960 | 385AHPDVDI-1 1/2" | Compressed Air (Aluminium) |
| 41G-1/4" | 147G | Gas Analysis (Stainless Steel) |
| 15/80 | 390AHP | Compressed Air (Aluminium) |
| 41G-1/2" | 148G | Gas Analysis (Stainless Steel) |
| 2002N-1B1-DX | 360AFI 1/4" 70C | Compressed Air (Aluminium) |
| 45S6-1/4" | 147 | Gas Analysis (Stainless Steel) |
| 2003N-1B1-DX | 360AFI 3/8" 70C | Compressed Air (Aluminium) |
| 45S6-1/2" | 148 | Gas Analysis (Stainless Steel) |
| 2004N-1B1-DX | 365AFI 1/2" 70C | Compressed Air (Aluminium) |
| 45G-1/4" | 147G | Gas Analysis (Stainless Steel) |
| 2104N-1B1-DX | 370AFI 1/2" 70C | Compressed Air (Aluminium) |
| 45G-1/2" | 148G | Gas Analysis (Stainless Steel) |
| 2206N-1B1-DX | 380AHPFVDI 3/4" 70C | Compressed Air (Aluminium) |
| 37/12-1/2" | 132HHP / 6000 psig | Gas Analysis (Stainless Steel) |
| 2208N-1B1-DX | 380AHPFVDI 1" 70C | Compressed Air (Aluminium) |
| 2312N-1B1-DX | 385AHPFVDI 1 1/2" 70C | Compressed Air (Aluminium) |
| A15/80-DX | 390AHPFVDI 2" 70C | Compressed Air (Aluminium) |
| 37/25-1/2" | 142HHP / 3000 psig | Gas Analysis (Stainless Steel) |
| 912A* | 230A 1/4" | Compressed Air (Aluminium) |
| 913A* | 230A 1/2" | Compressed Air (Aluminium) |
| 912* | 230 1/4" | Compressed Air (Aluminium) |
| 913* | 230 1/2" | Compressed Air (Aluminium) |
| 82-700 | 235 1/4" | Compressed Air (Aluminium) |
| 38/12 | H130S-TR | Gas Analysis (Stainless Steel) |
| 82-702 | 235 1/2" | Compressed Air (Aluminium) |
| 38/25 | H140S-TR | Gas Analysis (Stainless Steel) |
| 82-700A | 235A 1/4" | Compressed Air (Aluminium) |
| A34 | 134S | Gas Analysis (Stainless Steel) |
| 82-702A | 235A 1/2" | Compressed Air (Aluminium) |
| 95T | 122P / 120P | Gas Analysis (Stainless Steel) |
| 915* | 250A (1/4" or 1/2") | Compressed Air (Aluminium) |
| 917* | 250A (1/4" or 1/2") | Compressed Air (Aluminium) |
Filter Regulators & Fast Loop Housings
| Balston model | Comparable Headline model | Type |
|---|---|---|
| AFR-940 | FR516-1/4" | Filter Regulators (Aluminium) |
| 31GCFL-1/4" | 137G-1/4"D | Fast Loop Housings (Stainless Steel) |
| AFR-940A | FRA516-1/4" | Filter Regulators (Aluminium) |
| 31S6FL-1/4" | 137-1/4"D | Fast Loop Housings (Stainless Steel) |
| AFR-920-1/4" | FRT516-1/4" | Filter Regulators (Aluminium) |
| 41GCFL-1/4" | 147G-1/4"D | Fast Loop Housings (Stainless Steel) |
| 41S6FL-1/4" | 147-1/4"D | Fast Loop Housings (Stainless Steel) |
| AFR-920A-1/4" | FRAT066-1/4" | Filter Regulators (Aluminium) |
| 48S6 | 126IL-3 | Fast Loop Housings (Stainless Steel) |
| 49S6 | 146IL-3 | Fast Loop Housings (Stainless Steel) |
| AFR-915A-1/2" | FRAT076-1/2" | Filter Regulators (Aluminium) |
Vacuum Pump Exhaust Housings
| Balston model | Comparable Headline model | Type |
|---|---|---|
| 9955-12-371H | 420-50CS | Aluminium |
| CV-0112-371H | 420S-50CS | Stainless Steel |
| 18/18-371H | 425-50CS | Aluminium |
| CV-0118-371H | 425S-50CS | Stainless Steel |
| AR-0316-371H | 430-50CS | Aluminium |
| ACV-0135-371H | 430S-50CS | Stainless Steel |
| AR-0335-371H | 433-50CS | Aluminium |
| ACV-0335-371H | 433S-50CS | Stainless Steel |
| AR-0735-371H | 437-50CS | Aluminium |
| ACV-0735-371H | 437S-50CS | Stainless Steel |
| AR-0780-371H | 447-50CS | Aluminium |
| ACV-0780-371H | 447S-50CS | Stainless Steel |
| AR-1680-371H | 456-50CS | Aluminium |
| ACV-1680-371H | 456S-50CS | Stainless Steel |
Enter any Balston or Finite part number for the comparable Headline part.
Frequently asked questions
What replaces a Balston 95S6 housing?
Headline's chart gives the 120 for the 95S6-1/8" and the 122 for the 95S6-1/4". Both are weld-free 316L stainless steel.
Will my Balston elements fit a Headline housing?
Headline makes its elements in the same industry-standard sizes. Tell us the element and the housing and we confirm the fit.
Can Sarvesh supply these in India?
Yes. Sarvesh Analytics in Pune, India, is the exclusive representative of Headline Filters for the Indian subcontinent. Send the part numbers and quantities for a quote.
Are these parts made by Parker?
No. They are Headline Filters products. Headline's charts give them as comparable to the Parker part, and neither Headline nor Sarvesh is connected to Parker-Hannifin.
Parker, Balston and Finite are registered trademarks of Parker-Hannifin Corporation. Headline Filters and Sarvesh Analytics are not affiliated with Parker-Hannifin; names and part numbers identify a comparable product only. Suggested alternatives from Headline's published charts: check the specification for your duty, and we confirm it before quoting.