For OEMs and system builders

The analyser inside your equipment, made in India.

Furnaces, nitrogen and oxygen generators, gas mixers, air dryers, electrolysers and process skids all need a gas reading their customers can trust. ACCURRA analysers are designed and built by Sarvesh in Pune, configured from a published ordering code, and wired to the outputs your control system already uses.

Why builders design in ACCURRA

Less to engineer, less to stock, less to explain to your customer.

01

One code, one configuration

Every ACCURRA-S and ACCURRA-Hz is specified by a published ordering code: gas, range, second channel, pump, auto-calibration and power. Your drawing and your purchase order quote the same code, so every repeat unit matches the first.

02

Speaks your control system

Isolated 4-20 mA scaled to any part of the range, Modbus RTU over RS 485, and failsafe alarm relays set as Lo-LoLo, Lo-Hi or Hi-HiHi. Your PLC reads the value, the status and the alarms without an interface card.

03

Two gases, one enclosure

ACCURRA-S carries two different sensors in series, each with its own electronics, output, relays and Modbus ID. Oxygen and dew point, or methane and CO2, take one panel cut-out and one line on your bill of materials.

04

Fewer consumables for your customer

ACCURRA-TCD needs no reference gas, so your design drops a cylinder and a regulator. Paramagnetic oxygen models have no consumable sensor. Calibration and alarm history are stored in the analyser for audits.

05

The whole sample path

Probes, filters, coolers, the i-Cons conditioner and the SV-200 vaporiser come from the same supplier as the analyser, with Headline Filters supplied through Sarvesh. One supplier answers for the reading, from the tapping point to the output.

06

Designed and made in India

Developed by our own R&D team and built at our Talwade factory since 2002, under a quality system certified to ISO 9001:2015 by TÜV. An Indian-made analyser adds Indian-made content to the equipment you sell.

Match it to your machine

What you build, and the analyser that goes in it.

Each row links to the application note your engineers can use to check the measurement point and the sample path.

You buildThe measurementAnalyserApplication note
Heat-treatment, sintering and bright-annealing furnacesTrace oxygen, dew point, hydrogen3015 + M015, ACCURRA-TCDFurnace atmospheres
Controlled-atmosphere brazing furnacesOxygen ppm and dew point from one tapping3015 + M015CAB furnaces
PSA and membrane nitrogen generatorsResidual oxygen in the product3015 or 3030Nitrogen purity
PSA and VPSA oxygen plantsOxygen purity, about 93 %3090 or 3130Medical oxygen plants
Gas mixers for welding and food packagingCO2 and oxygen in the blend6030, 3030, ACCURRA-TCDWelding gas mixtures
Boilers, burners and thermic-fluid heatersFlue gas oxygen for combustion trimACCURRA-ZrBoiler flue oxygen
Compressed air dryersPressure dew pointM015Compressed air dew point
CA stores and ripening roomsOxygen and CO2 in the room3030 + 6030CA fruit stores
Glove boxes and isolatorsOxygen ppm and dew point3015 + M015Glove boxes
Hydrogen electrolysersHydrogen in oxygen, oxygen in hydrogenACCURRA-TCD, ACCURRA-HzElectrolyser gas
Dryer, reactor and solvent skids in classified areasOxygen in the inert gasACCURRA-Hz, INFINITY-TxBlanketing and inerting
Biogas upgrading skids and gas gensetsMethane and CO24030 + 6030Biogas and CBG

Building something not on this list? Send the gas, the range and the conditions at the tapping point. Bespoke applications are where we start every project.

Integration at a glance

What your design team needs to know.

From the ACCURRA datasheets. Full figures, ordering codes and dimensions are in the datasheets.

ItemACCURRA-S (safe area)ACCURRA-Hz (hazardous area)
Enclosure19 inch rack or panel, 134 H x 483 W x 180 or 280 D mm, IP 20, about 6 kgWall mounted, 410 H x 370 W x 245 D mm, IP 66, about 12 kg; Gas Group IIC, Zone 1 and 2, T6 as per IS/IEC 60079-1:2014
Power100 to 240 V AC, 50/60 Hz, 45 W24 V DC, 30 W, or 100 to 240 V AC, 50/60 Hz, 45 W
Analog outputIsolated 4-20 mA, user-configurable over the measurement range; dual range with range ID relayIsolated 4-20 mA, dual range, maximum load 500 ohm
CommunicationModbus RTU over RS 485: read the measured value, status, set-up and history
RelaysTwo independent failsafe alarm relays, set as Lo-LoLo, Lo-Hi or Hi-HiHi; relays for fault, sample pump, range ID or calibration valves, by model
CalibrationCalibration check facility; optional cyclic and remote auto-calibration; output freeze or follow during calibrationCalibration without opening the covers, tamper-proof; optional auto-calibration through external valves
RecordsCalibration history with deviation values, alarm and fault history; password-protected set-up
SampleDry, oil-free, non-condensing; 2 to 10 psig, about 1 LPM (0.6 LPM for ACCURRA-TCD), dust below 3 micron. Where your sample differs, we design the conditioning around it.
How an OEM project runs

From your specification to the units on your line.

1. Your specification

Send the equipment, the gas, the range, the sample conditions and the number of units you expect to build. A data sheet or a drawing is enough to start.

2. Application review

An applications engineer checks the measurement point and the sample path, then fixes the model, range and options as one ordering code.

3. Your first build

The first unit is built, tested and calibrated at our Talwade factory to documented procedures, and fitted into your prototype or first machine.

4. Repeat units

Later units are built to the same ordering code and configuration, so the analyser in your hundredth machine behaves like the one in your first.

5. Your customer's plant

Our support line, spares and calibration advice stay available to you for the installed base, from our office in Pune.

Questions first?

Call sales on +91 94 2300 4179, or write to info@sarveshindia.com.

What happens next

Your request goes straight to our sales and applications team, who will reply with questions or a proposal for your build.

Already have a specification?

Attach it to the form, or use the application data sheet for the process details.

Datasheets

ACCURRA-S, ACCURRA-Hz, ACCURRA-TCD, ACCURRA-Zr and the sample conditioners are on the downloads page.

Request an OEM quote