Industry

Gas Analysers for refineries and petrochemical plants

Refineries buy hydrogen by the purity, burn fuel by the oxygen reading, and keep air out of flare and blanketing systems by trace oxygen. Sarvesh supplies the thermal conductivity, zirconia and oxygen analysers for these points, hazardous-area versions for Zone 1, and the sample systems that keep them reading.

Quick answer

Sarvesh supplies ACCURRA-TCD hydrogen purity analysers for make-up, recycle and PSA hydrogen, ACCURRA-Zr in-situ oxygen analysers for fired heaters and reformer furnaces, trace oxygen analysers for flare gas recovery and blanketing, and ACCURRA-Hz and INFINITY-Tx for Zone 1 areas.

Figures from Sarvesh datasheets

Measurement map

Where we measure in refineries and petrochemical plants

One row per application. Each application page gives the models, ranges and sample handling.

ApplicationWhat we measureProducts
Flare-gas recovery oxygen ingressOxygen, hazardous areaACCURRA-Hz
Refinery hydrogen purity: make-up, recycle and PSAPSA product hydrogen; Make-up and recycle gas, by review; Hydrogen, hazardous areaACCURRA-TCD, ACCURRA-Hz, Engineered analyser panels, Headline Filters
Fired heater and reformer furnace flue gas oxygenFlue gas oxygen, in situ; Hot or dusty locations; CO in flue gas, extractiveACCURRA-Zr, ACCURRA-S, SP and SRP sample probes
What matters here

What matters when you measure gas in refineries and petrochemical plants

  • Hydrogen purity of make-up, recycle and PSA product gas by thermal conductivity
  • In-situ zirconia oxygen for fired heaters and reformer furnaces, with probes to 1400 °C
  • Oxygen ingress on flare gas recovery and tank blanketing
  • ACCURRA-Hz and INFINITY-Tx for Zone 1 and 2, Gas Group IIC

Refinery samples are flammable, often sour and usually in a classified area. The analyser is the easy part; the sample system decides whether it stays in service. We ask for composition including H2S, pressure, temperature and the area classification, and design the knock-out, filtration and vent with the analyser.

Specifications from refinery owners and their engineering consultants are detailed. Send the analyser data sheet with the enquiry and we respond clause by clause, saying what we meet and what we do not. We make no SIL claim.

Sample Handling

Where sampling goes wrong

Sour gas needs its own sample path

H2S and other sulphur compounds attack sensors and wetted parts and are a hazard at the vent. Tell us the H2S level so that the sample path and materials are chosen for it.

Heavier hydrocarbons condense

Recycle and fuel gas carry hydrocarbons that condense when the sample cools. Keep the sample above its hydrocarbon dew point or knock the liquid out with a coalescing filter before the analyser.

Fired heater oxygen depends on where you measure

Air leaks into the convection section raise the oxygen reading above what the burners see. Mount the zirconia probe where the flue gas represents combustion, and keep the probe within its temperature option.

Almost every point is classified

Refinery sample points are usually in Zone 1 or 2. ACCURRA-Hz and INFINITY-Tx stand in the classified area; ACCURRA-S and ACCURRA-TCD go in a safe-area shelter or room with the sample piped to them.

Headline Filters

Filters and sample handling

Sarvesh Analytics is the exclusive representative of Headline Filters, the UK-based filter maker, for the Indian subcontinent.

Enquiry

What to send for a quote

  • The sample point: PSA product, make-up or recycle gas
  • The full composition with typical and extreme values, including heavier hydrocarbons and H2S
  • Pressure and temperature at the tapping point, and the area classification where the analyser will stand
  • The heater or furnace type and the fuel
  • Flue gas temperature and dust at the proposed probe location
  • Duct or stack dimensions and the mounting flange
  • The area classification at the probe

Start the application data sheet

Questions

Frequently asked questions

Can you measure hydrogen purity in refinery recycle gas?

ACCURRA-TCD measures hydrogen in methane, 0 to 100 %, 0 to 3 % or 97 to 100 %. Recycle gas also carries heavier hydrocarbons and H2S, so send the composition and we confirm the reading error and the sample system.

Do you supply analysers for Zone 1 in a refinery?

ACCURRA-Hz is certified for Gas Group IIC, Zone 1 and 2, T6, and INFINITY-Tx is a loop-powered oxygen transmitter for hazardous areas.

Do you supply sample vaporisers for LPG?

Our SV-200 vaporises cryogenic oxygen, nitrogen and argon, and SV-400 vaporises condensed sample in wet gas. For LPG or LNG, send the sample details and we review whether either suits it.

Can you respond to a consultant's analyser specification?

Yes. Send the data sheet and we reply clause by clause, stating what we meet and what we do not.

Which analyser measures oxygen in a fired heater?

ACCURRA-Zr measures 0.1 to 21 % oxygen in situ, is calibrated on air at a single point, and has high-dust and 1400 °C probe options.