Dew point monitoring for lithium-ion battery dry rooms and electrode drying

Cell assembly needs very low dew point; continuous monitoring supports yield. Sarvesh supplies ACCURRA-S M015, built in Pune, with sampling matched to the stream.

  • ISO 9001:2015, certified by TÜV
  • Designed and built in Pune since 2002
  • Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO
Quick answer

Use ACCURRA-S M015. Cell assembly needs very low dew point; continuous monitoring supports yield. Ambient sampling needs a pump (M015 has none); dry-room dew points can sit below the lowest sensor range on some lines.

Updated 2 November 2026 · Figures from Sarvesh datasheets

The measurement and why it matters

Cell assembly needs very low dew point; continuous monitoring supports yield. This is a good fit, with one configuration or sample-handling point to confirm before we quote.

In furnaces, chambers and dry rooms the atmosphere is part of the recipe. A few ppm of oxygen, a dew point or a hydrogen share decides surface finish, yield or safety, and a leak or a drifting gas supply shows up in the analyser before it shows up in the product.

These atmospheres are usually clean at the analyser but can be hot, sooty or particulate-laden at the furnace take-off. Sample from the right point, keep lines short and use dry stainless tubing. Tell us the furnace or chamber volume and flow so we can confirm the sample path.

Typical buyers in India: cell and pack manufacturers, gigafactory project teams. Where this matches your plant, send us the gas, range, pressure and temperature at the tapping point and we will confirm the analyser and sample path.

Models and ranges

ModelMeasuresRangeSensor and notes
M015Dew point-80 to +20 CCeramic sensor; no internal pump, no auto-calibration

Process notes

What the analyser reads here

Gases of interest: Dew point. Analyser fit: ACCURRA-S M015.

The table above lists each model with its range; where a row says to confirm the range, we check it against the datasheet for your application before quoting.

What to settle before ordering

Ambient sampling needs a pump (M015 has none); dry-room dew points can sit below the lowest sensor range on some lines.

We would rather confirm these points at the start than discover them at commissioning, so please include them with your process details.

Sampling and installation

  • Every ACCURRA-S has an internal fine filter and rotameter. Regulate sample pressure and flow externally; the catalogue recommends about 1 LPM and a sample pressure of 2 to 10 psig.
  • Models 3015, M015, 3130 and 3190 are supplied without an internal sample pump. Tell us the sample pressure and we will confirm the sample path or add a pump.
  • Models 3015 and M015 have no auto-calibration, so plan a calibration routine with the right reference gas.
  • Keep sample lines short, clean and dry, and vent the sample somewhere safe.

ACCURRA-S sample specification: non-corrosive, non-toxic, non-flammable, non-condensing and dry, free from entrained oil; sample pressure 2 to 10 psig, regulated externally; flow about 1 LPM; dust below 3 micron. Where your sample differs, we design conditioning around it.

Send us your process data

Application data sheet

The same pre-order design inputs our engineers design from, online. Fill in what you know, leave the rest. Your draft saves as you go, and you can print or send it when ready.

Start the data sheet
What the data sheet asks for

Send what you have and we will ask for the rest.

  • The gases to measure, the range, and the accuracy you need
  • Background gases and their typical composition
  • Sample temperature, pressure and dew point at the tapping point
  • Dust level, and whether the gas carries tar, oil or condensable vapour
  • Process connection and, for ducts, the duct diameter
  • Where the sample vents to, and at what pressure
  • Area classification of the tapping point and of the analyser location, and the IP protection needed
  • Distance between the tapping point and the analyser
  • Outputs you need: 4-20 mA, dual range, relays, Modbus RTU
  • Calibration approach, calibration gas available, and whether blowback is required
  • Utilities at site: power supply, instrument air, nitrogen, steam and cooling water, and the ambient temperature range
  • Gases and ranges: Dew point
  • The point to confirm: Ambient sampling needs a pump (M015 has none); dry-room dew points can sit below the lowest sensor range on some lines.

Frequently asked questions

Which analyser suits lithium-ion battery dry rooms and electrode drying?

ACCURRA-S M015 Cell assembly needs very low dew point; continuous monitoring supports yield.

What should I check before ordering for lithium-ion battery dry rooms and electrode drying?

Ambient sampling needs a pump (M015 has none); dry-room dew points can sit below the lowest sensor range on some lines.

Who typically needs this?

Typical buyers in India: cell and pack manufacturers, gigafactory project teams.

Can Sarvesh support a variation of this application?

Yes. If your process differs from the usual case, send the details. Application engineering is where we start every project, and bespoke applications are welcome.