Oxygen, moisture and hydrogen analysis for research furnaces and CVD/ALD labs

University and CSIR tube furnaces need low oxygen and moisture. Sarvesh supplies ACCURRA-TCD, built in Pune, with sampling matched to the stream.

  • ISO 9001:2015, certified by TÜV
  • Designed and built in Pune since 2002
  • Supplied to Reliance, Tata Steel, Indian Oil, Linde and ISRO
Quick answer

Use ACCURRA-S, TCD. University and CSIR tube furnaces need low oxygen and moisture. Small orders; reference value.

Updated 2 November 2026 · Figures from Sarvesh datasheets

The measurement and why it matters

University and CSIR tube furnaces need low oxygen and moisture. This is a good fit, with one configuration or sample-handling point to confirm before we quote.

Research and nuclear users need low oxygen and moisture in argon or nitrogen atmospheres and a clear record of instrument health. ACCURRA-S stores calibration, alarm and fault records and password-protects calibration and set-up.

Volumes are often small and closed, so the sample drawn by the analyser has to be returned or limited. Orders are small and technical, and we treat each set-up as an application engineering job.

Typical buyers in India: IITs and CSIR labs (IITs are existing customers). Where this matches your plant, send us the gas, range, pressure and temperature at the tapping point and we will confirm the analyser and sample path.

Models and ranges

ModelMeasuresRangeSensor and notes
ACCURRA-TCDBinary gas analysis (O2 ppm, moisture, H2)Binary mixturesThermal conductivity, no reference gas

Process notes

What the analyser reads here

Gases of interest: O2 ppm, moisture, H2. Analyser fit: ACCURRA-S, TCD.

The table above lists each model with its range; where a row says to confirm the range, we check it against the datasheet for your application before quoting.

What to settle before ordering

Small orders; reference value.

We would rather confirm these points at the start than discover them at commissioning, so please include them with your process details.

This page overlaps with:

Sampling and installation

  • Every ACCURRA-S has an internal fine filter and rotameter. Regulate sample pressure and flow externally; the catalogue recommends about 1 LPM and a sample pressure of 2 to 10 psig.
  • Keep sample lines short, clean and dry, and vent the sample somewhere safe.

Send us your process data

Application data sheet

The same pre-order design inputs our engineers design from, online. Fill in what you know, leave the rest. Your draft saves as you go, and you can print or send it when ready.

Start the data sheet
What the data sheet asks for

Send what you have and we will ask for the rest.

  • The gases to measure, the range, and the accuracy you need
  • Background gases and their typical composition
  • Sample temperature, pressure and dew point at the tapping point
  • Dust level, and whether the gas carries tar, oil or condensable vapour
  • Process connection and, for ducts, the duct diameter
  • Where the sample vents to, and at what pressure
  • Area classification of the tapping point and of the analyser location, and the IP protection needed
  • Distance between the tapping point and the analyser
  • Outputs you need: 4-20 mA, dual range, relays, Modbus RTU
  • Calibration approach, calibration gas available, and whether blowback is required
  • Utilities at site: power supply, instrument air, nitrogen, steam and cooling water, and the ambient temperature range
  • Gases and ranges: O2 ppm, moisture, H2
  • The point to confirm: Small orders; reference value.

Frequently asked questions

Which analyser suits research furnaces and CVD/ALD labs?

ACCURRA-S, TCD University and CSIR tube furnaces need low oxygen and moisture.

What should I check before ordering for research furnaces and CVD/ALD labs?

Small orders; reference value.

Who typically needs this?

Typical buyers in India: IITs and CSIR labs (IITs are existing customers).

Can Sarvesh support a variation of this application?

Yes. If your process differs from the usual case, send the details. Application engineering is where we start every project, and bespoke applications are welcome.