Use ACCURRA-S 3015 + M015. Argon cover gas and nuclear glove boxes track oxygen and moisture. Procurement through DAE; validate each use.
The measurement and why it matters
Argon cover gas and nuclear glove boxes track oxygen and moisture. This is a good fit, with one configuration or sample-handling point to confirm before we quote.
Research and nuclear users need low oxygen and moisture in argon or nitrogen atmospheres and a clear record of instrument health. ACCURRA-S stores calibration, alarm and fault records and password-protects calibration and set-up.
Volumes are often small and closed, so the sample drawn by the analyser has to be returned or limited. Orders are small and technical, and we treat each set-up as an application engineering job.
Typical buyers in India: DAE and its labs (an existing customer). Where this matches your plant, send us the gas, range, pressure and temperature at the tapping point and we will confirm the analyser and sample path.
Models and ranges
| Model | Measures | Range | Sensor and notes |
|---|---|---|---|
| 3015 | Trace oxygen | 0 to 1000 ppm (min range 0 to 100 ppm) | Electrochemical; no internal pump, no auto-calibration |
| M015 | Dew point | -80 to +20 C | Ceramic sensor; no internal pump, no auto-calibration |
Process notes
What the analyser reads here
Gases of interest: O2 ppm, moisture. Analyser fit: ACCURRA-S 3015 + M015.
The table above lists each model with its range; where a row says to confirm the range, we check it against the datasheet for your application before quoting.
What to settle before ordering
Procurement through DAE; validate each use.
We would rather confirm these points at the start than discover them at commissioning, so please include them with your process details.
Related applications
This page overlaps with:
Sampling and installation
- Every ACCURRA-S has an internal fine filter and rotameter. Regulate sample pressure and flow externally; the catalogue recommends about 1 LPM and a sample pressure of 2 to 10 psig.
- Models 3015, M015, 3130 and 3190 are supplied without an internal sample pump. Tell us the sample pressure and we will confirm the sample path or add a pump.
- Models 3015 and M015 have no auto-calibration, so plan a calibration routine with the right reference gas.
- Keep sample lines short, clean and dry, and vent the sample somewhere safe.
ACCURRA-S sample specification: non-corrosive, non-toxic, non-flammable, non-condensing and dry, free from entrained oil; sample pressure 2 to 10 psig, regulated externally; flow about 1 LPM; dust below 3 micron. Where your sample differs, we design conditioning around it.
Send us your process data
The same pre-order design inputs our engineers design from, online. Fill in what you know, leave the rest. Your draft saves as you go, and you can print or send it when ready.
What the data sheet asks for
Send what you have and we will ask for the rest.
- The gases to measure, the range, and the accuracy you need
- Background gases and their typical composition
- Sample temperature, pressure and dew point at the tapping point
- Dust level, and whether the gas carries tar, oil or condensable vapour
- Process connection and, for ducts, the duct diameter
- Where the sample vents to, and at what pressure
- Area classification of the tapping point and of the analyser location, and the IP protection needed
- Distance between the tapping point and the analyser
- Outputs you need: 4-20 mA, dual range, relays, Modbus RTU
- Calibration approach, calibration gas available, and whether blowback is required
- Utilities at site: power supply, instrument air, nitrogen, steam and cooling water, and the ambient temperature range
- Gases and ranges: O2 ppm, moisture
- The point to confirm: Procurement through DAE; validate each use.
Recommended Sarvesh products
Frequently asked questions
Which analyser suits reactor cover-gas and glove-box atmospheres (O2 and moisture in argon)?
ACCURRA-S 3015 + M015 Argon cover gas and nuclear glove boxes track oxygen and moisture.
What should I check before ordering for reactor cover-gas and glove-box atmospheres (O2 and moisture in argon)?
Procurement through DAE; validate each use.
Who typically needs this?
Typical buyers in India: DAE and its labs (an existing customer).
Can Sarvesh support a variation of this application?
Yes. If your process differs from the usual case, send the details. Application engineering is where we start every project, and bespoke applications are welcome.
More in Electronics, cable and research
- Semiconductor and electronics gas purity
- Optical fibre and cable manufacturing
- Welding and laser gas mixtures
- Aerospace, nuclear and research laboratories
- Metal additive manufacturing build-chamber oxygen
- Glove boxes and isolators (O2 and moisture)
- Lithium-ion battery dry rooms and electrode drying
- Research furnaces and CVD/ALD labs
- All electronics, cable and research applications
- Browse analysers by gas