Headline's range of vacuum pump exhaust oil mist filters runs to 1 products in these families: filter elements.
How the CS-type element works
- The CS element is borosilicate glass microfibre with a silica binder, compatible with compressor lubricants. An inner capture layer holds the oil droplets; they grow as they move through it and pass to an outer drainage layer, from which they drain into the bowl.
- Headline rates it at 99.9 % efficiency at 0.1 micron, with an initial dry pressure drop below 0.1 bar. Change the element at 0.3 bar, or at the pump maker's maximum back pressure if that is lower.
Sizing the housing
- Choose the housing by the pump's maximum free air displacement, and never below it, or efficiency falls. Headline's housings cover 5 to 765 m³/h, in aluminium (models 420 to 456, to 120 °C) or 316L stainless steel (420S to 456S, to 200 °C).
- Use stainless steel where the exhaust can exceed 120 °C or carries corrosive chemicals.
- Mount the filter vertically, fit a pipe and collection device to the drain, and use flexible ducting where vibration or heat is high.
Headline products for this duty
Headline lists these 1 products for this application, grouped by family. Open a family to see every model; each links to its card with ports and rating.
Filter elements
1 product
| Model | Ports | Rating | Options |
|---|---|---|---|
| 45-250-50CS | – | – | Grade 50CS |
The filter finder takes your gas, pressure, temperature and port and returns the Headline housings rated for it, with the element grade and binder.
Choose the housing
Selection chart
| Maximum flow, m³/h | Aluminium | Stainless steel |
|---|---|---|
| 5 | 420 | 420S |
| 15 | 425 | 425S |
| 35 | 430 | 430S |
| 75 | 433 | 433S |
| 150 | 443 | 443S |
| 170 | 437 | 437S |
| 340 | 447 | 447S |
| 765 | 456 | 456S |
What comes with the housings
- Every housing except the 420 has a captured outlet, so the clean exhaust can be ducted away or treated further.
- Models 433 and larger come with a back-pressure gauge and an anti-re-entrainment mesh pad.
- Stainless steel models from the 433S up have automatic pressure relief as standard.
- All housings are rated to 2 bar.
- Multi-element housings can have other connections; the 437, for example, comes with 3 inch NPT threads as standard, or KF80, DN80 or 3 inch 150 lb flanges.
- Each housing is supplied with its elements fitted. Specify non-standard connections when ordering.
- Replacement elements come in packs of 3, 7 or 10, for example 51-230-50CS (7) or 51-476-50CS (10); the 25-64-50CS comes in packs of 3 or 10 only.
- The CS element is rated to 200 °C in the bulletin; the aluminium housing limits the filter to 120 °C.
Specifications
Aluminium, to 120 °C
| Specification | 420 | 425 | 430 | 433 | 443 | 437 | 447 | 456 |
|---|---|---|---|---|---|---|---|---|
| Port, NPT | 1/2" | 3/4" | 1" | 1 1/2" | 2" | 3" | 3" | 3" |
| Drain port | M6 | 1/8" | 1/8" | 1/4" | 1/4" | 1/4" | 1/4" | 1/4" |
| Gauge port | – | – | – | 1/4" | 1/4" | 1/4" | 1/4" | 1/4" |
| Maximum flow, m³/h | 5 | 15 | 35 | 75 | 150 | 170 | 340 | 765 |
| Maximum temperature, °C | 120 | 120 | 120 | 120 | 120 | 120 | 120 | 120 |
| Internals | – | – | – | Aluminium, 316L | Aluminium, 316L | Aluminium, 316L | Aluminium, 316L | Aluminium, 316L |
| Gaskets | – | Nitrile | Nitrile | Nitrile | Nitrile | Nitrile | Nitrile | Nitrile |
| A, mm | 22 | 33.5 | 33.5 | 70 | 70 | 85 | 85 | 114 |
| B, mm | 50 | 89 | 89 | 240 | 240 | 330 | 330 | 492 |
| C, mm | 93 | 153 | 295 | 435 | 735 | 515 | 776 | 836 |
| D, mm | – | 90 | 230 | 178 | 178 | 250 | 250 | 406 |
| Volume, cc | 95 | 496 | 1260 | 9500 | 16000 | 25000 | 35000 | 65000 |
| Gasket set, nitrile / Viton | – | GN425 / GV425 | GN425 / GV425 | GN433 / GV433 | GN433 / GV433 | GN437 / GV437 | GN437 / GV437 | GN456 / GV456 |
| Element | 25-64-50CS | 51-89-50CS | 51-230-50CS | 51-230-50CS | 51-476-50CS | 51-230-50CS | 51-476-50CS | 51-476-50CS |
| Number of elements | 1 | 1 | 1 | 3 | 3 | 7 | 7 | 16 |
316L stainless steel, to 200 °C
| Specification | 420S | 425S | 430S | 433S | 443S | 437S | 447S | 456S |
|---|---|---|---|---|---|---|---|---|
| Port, NPT | 1/2" | 3/4" | 1" | 1 1/2" | 2" | 3" | 3" | 3" |
| Drain port | 1/8" | 1/8" | 1/8" | 1/4" | 1/4" | 1/4" | 1/4" | 1/4" |
| Gauge port | – | – | – | 1/4" | 1/4" | 1/4" | 1/4" | 1/4" |
| Maximum flow, m³/h | 5 | 15 | 35 | 75 | 150 | 170 | 340 | 765 |
| Maximum temperature, °C | 200 | 200 | 200 | 200 | 200 | 200 | 200 | 200 |
| Body and internals | 316L | 316L | 316L | 316L | 316L | 316L | 316L | 316L |
| Gaskets | Viton | Viton | Viton | Viton | Viton | Viton | Viton | Viton |
| A, mm | 22.5 | 33.5 | 33.5 | 72 | 72 | 87 | 87 | 193 |
| B, mm | 60 | 89 | 89 | 300 | 300 | 356 | 356 | 495 |
| C, mm | 102 | 143 | 278 | 429 | 735 | 510 | 790 | 1000 |
| D, mm | 70 | 90 | 230 | 219 | 219 | 273 | 273 | 406 |
| Volume, cc | 170 | 496 | 1280 | 9500 | 16000 | 25000 | 35000 | 65000 |
| Gasket set, Viton / nitrile | GV420S / GN420S | GV425S / GN425S | GV425S / GN425S | GV433S / GN433S | GV433S / GN433S | GV437S / GN437S | GV437S / GN437S | GV456S / GN456S |
| Element | 25-64-50CS | 51-89-50CS | 51-230-50CS | 51-230-50CS | 51-476-50CS | 51-230-50CS | 51-476-50CS | 51-476-50CS |
| Number of elements | 1 | 1 | 1 | 3 | 3 | 7 | 7 | 16 |
Frequently asked questions about sizing and ordering
Which Headline exhaust filter fits my vacuum pump?
Take the pump's maximum free air displacement and choose the first housing rated at or above it: 5, 15, 35, 75, 150, 170, 340 or 765 m³/h. Never choose one rated below the pump, or efficiency falls.
What comes with the larger housings?
From the 433 up, a back-pressure gauge and an anti-re-entrainment mesh pad. Stainless steel models from the 433S up also have automatic pressure relief.
Can I get flanged connections?
Multi-element housings can be supplied with other connections. The 437, for example, is available with KF80, DN80 or 3 inch 150 lb flanges instead of 3 inch NPT.
In what packs are replacement elements sold?
Packs of 3, 7 or 10, for example 51-230-50CS (7). The 25-64-50CS comes in packs of 3 or 10 only.
Oil mist filters for the exhaust of oil-sealed vacuum pumps: the CS-type coalescing element, aluminium and stainless steel housings sized by pump flow from 5 to 765 m³/h, and installation guidance.
Frequently asked questions
Which element is used for vacuum pump exhaust?
A CS-type coalescing element: borosilicate microfibre with a silica binder. The element sizes include 25-64-50CS, 51-89-50CS, 51-230-50CS and 51-476-50CS, depending on the housing.
When should the element be changed?
When the pressure drop reaches 0.3 bar, or the pump maker's maximum back pressure if that is lower.
Aluminium or stainless steel?
Stainless steel if the exhaust can exceed 120 °C or carries corrosive chemicals; aluminium otherwise.