For 1 to 2 inch process lines Headline makes the 150 and 160 series in 316L stainless steel, rated to 100, 200 or 400 bar at 200 °C. At 7 bar and a 0.15 bar pressure drop a 150 with a grade 50 element passes about 302 Nm³/h of air and a 160 about 516. The range also includes bowl-up analyser housings, adsorption housings and the HFM100 membrane.
150 and 160 series for 1 to 2 inch lines
Entirely 316L, with Viton or PTFE seals, for liquids and gases and for high-flow corrosive duty. Rated to 100 bar, 200 bar (HP) or 400 bar (VP) at 200 °C, and to 450 °C with a high-temperature gasket at a reduced pressure. Flanged connections and Monel or Hastelloy bodies can be made to order. The 150 holds 1,500 cc and takes a 51-230 element; the longer 160 holds 2,700 cc and takes a 51-476 element.
Every 150 and 160 model with dimensions, weights, gaskets and support cores.
Flow rates
150 series (51-230 elements)
| Line pressure, bar g | Grade 30 | Grade 40 | Grade 50 | Grade 60 | Grade 70 |
|---|---|---|---|---|---|
| 0 | 12 | 22 | 38 | 89 | 101 |
| 1 | 24 | 44 | 76 | 178 | 202 |
| 2 | 36 | 66 | 113 | 268 | 303 |
| 3 | 48 | 83 | 151 | 357 | 404 |
| 4 | 59 | 110 | 189 | 446 | 505 |
| 5 | 71 | 133 | 227 | 535 | 607 |
| 6 | 83 | 155 | 265 | 624 | 708 |
| 7 | 95 | 177 | 302 | 714 | 809 |
| 8 | 107 | 199 | 340 | 803 | 910 |
| 9 | 119 | 221 | 378 | 892 | 1010 |
| 10 | 131 | 243 | 416 | 981 | 1110 |
| Water, l/h | 214 | 400 | 705 | 1770 | 1910 |
Air at 20 °C in Nm³/h, and water in l/h, with a 0.15 bar pressure drop.
160 series (51-476 elements)
| Line pressure, bar g | Grade 30 | Grade 40 | Grade 50 | Grade 60 | Grade 70 |
|---|---|---|---|---|---|
| 0 | 25 | 44 | 65 | 107 | 114 |
| 1 | 49 | 87 | 129 | 213 | 228 |
| 2 | 74 | 131 | 194 | 320 | 341 |
| 3 | 99 | 175 | 258 | 426 | 455 |
| 4 | 123 | 219 | 323 | 533 | 569 |
| 5 | 148 | 262 | 387 | 640 | 683 |
| 6 | 172 | 306 | 152* | 746 | 797 |
| 7 | 197 | 350 | 516 | 853 | 911 |
| 8 | 222 | 394 | 581 | 960 | 1020 |
| 9 | 246 | 497* | 646 | 1070 | 1140 |
| 10 | 271 | 481 | 710 | 1170 | 1250 |
| Water, l/h | 410 | 780 | 1200 | 2070 | 2240 |
Air at 20 °C in Nm³/h, and water in l/h, with a 0.15 bar pressure drop. * Printed as 152 for grade 50 at 6 bar; the bulletin's own s.c.f.m. figure gives 452 Nm³/h, which the calculator uses. * Printed as 497 for grade 40 at 9 bar; the bulletin's own s.c.f.m. figure gives 437 Nm³/h, which the calculator uses.
Bowl-up process and analyser housings: 129, 170, 170-LB, 137G-3
- Installed bowl up, with the drain in the head, so the inlet, outlet and drain pipework stays permanently connected. The bowl comes off by hand, with no tools and without undoing any pipework.
- A compact design for analyser protection, rated to 100 bar in stainless steel (129, 170, 170-LB) or 7 bar with a glass bowl (137G-3).
- Also available with a fourth 1/4" NPT port in the top of the bowl. The 170-LB has a long bowl and a longer element (22-64).
- The 129 is available with a PTFE seal, which needs a modified sealing design: add S to the code, for example 129S.
| Specification | 129 | 170 | 170-LB | 137G-3 |
|---|---|---|---|---|
| Port, NPT | 1/4" | 1/4" | 1/4" | 1/4" |
| Maximum pressure, bar | 100 | 100 | 100 | 7 |
| Maximum temperature, °C | 200 | 200 | 200 | 100 |
| Body | 316L | 316L | 316L | 316L |
| Bowl | 316L | 316L | 316L | Borosilicate glass |
| Volume, cc | 65 | 50 | 85 | 110 |
| Weight, kg | 0.92 | 0.66 | 0.75 | 1.0 |
| Gasket set | GV129 | GV170 | GV170 | GV137G-3 |
| Mounting bracket | MB129 | MB170 | MB170 | – |
| Glass fibre element | 12-57-xx | 22-35-xx | 22-64-xx | 25-64-xx |
| Stainless steel element | SS-120-xx | SS-170-xx | SS-170L-xx | SS-130-xx |
| PTFE element | PT-120-xx | PT-170-xx | PT-170L-xx | PT-130-xx |
From Headline's process gas bulletin; ask us for current availability.
In-line filters with a transparent bowl: 705N-IL, 127G-IL, 137G-IL
- In-line filters with a transparent bowl, so the element can be inspected without opening the line.
- For low-pressure duty. The housing stays in place and only the disposable element is replaced, which costs less over time and throws away less than a fully disposable filter.
| Specification | 705N-IL | 127G-IL | 137G-IL |
|---|---|---|---|
| Port | 7.0 mm spigot | 1/4" NPT | 1/4" NPT |
| Maximum pressure, bar | 7 | 7 | 7 |
| Maximum temperature, °C | 50 | 100 | 100 |
| Head, base and internals | PVC and nylon | 316L | 316L |
| Bowl | Nylon | Borosilicate glass | Borosilicate glass |
| Weight, kg | 0.06 | 0.21 | 0.65 |
| Gasket set | GV705 | GV127 | GV137 |
| Glass fibre element | 12-32-xx | 12-57-xx | 25-64-xx |
| Stainless steel element | SS-110-xx | SS-120-xx | SS-130-xx |
| PTFE element | PT-110-xx | PT-120-xx | PT-130-xx |
From Headline's process gas bulletin; ask us for current availability.
Stainless steel adsorption housings: 134CC, 146CC and VP versions
- Stainless steel adsorption housings for duties that need a large volume of adsorbent, over the full range of line pressures. Above 100 bar, use the VP versions.
- Size them by the volume of adsorbent and the contact time, not by flow.
| Specification | 134CC | 134VPCC | 146CC | 146VPCC |
|---|---|---|---|---|
| Port, NPT | 1/4" | 1/4" | 1/2" | 1/2" |
| Maximum pressure, bar | 100 | 400 | 100 | 400 |
| Maximum temperature, °C | 200 | 200 | 200 | 200 |
| Materials | 316L, Viton | 316L, Viton | 316L, Viton | 316L, Viton |
| Adsorbent volume, cc | 110 | 160 | 265 | 320 |
| Weight, kg | 0.7 | 4.5 | 1.1 | 6.5 |
| Gasket set | GV130 | GV130VP | GV130 | GVF130VP |
| Mounting bracket | MB130 | MB150 | MB130 | MB150 |
Adsorbents
| Adsorbent | Code | Removes |
|---|---|---|
| Activated carbon | CC | Hydrocarbons and other organic vapours |
| Molecular sieve 4A | 4A | CO2, NH3, H2S, SOx |
| Molecular sieve 13X | 13X | CO2, NH3, H2S, SOx, aromatics, amines |
| Silica gel | SG | Water vapour |
| Mixed bases | MB | Acidic gases: CO2, SOx, NOx, HCl |
| Potassium permanganate | PP | SOx and other acidic gases |
| Hopcalite | HO | CO, by catalytic oxidation to CO2 |
Check that the adsorbent does not also remove the gas you measure, and fit a coalescing filter ahead of it. More on vapour removal adsorbers.
From Headline's process gas bulletin; ask us for current availability.
HFM100 high-flow membrane housing
- A highly porous PTFE membrane in a 316L housing, with inlet and outlet ports and two bypass ports, all arranged for permanent pipework so the membrane can be changed easily.
- Three angled venturis spin the gas beneath the membrane. This keeps the membrane clean: gas passes through it to the sample outlet, and liquid leaves through the bypass ports.
- Very inert, and recommended for most applications except hydrofluoric acid. Use a coalescing pre-filter ahead of it and keep the membrane as the last line of protection.
- Headline's chart shows flow up to about 70 l/min against pressure drop; ask us for the figure at your flow.
| Specification | HFM100 |
|---|---|
| Port, NPT | 1/4" |
| Maximum pressure, bar | 150 (the bulletin's summary line says 100 bar; we confirm for your duty) |
| Maximum temperature, °C | 200 |
| Materials | 316L, Viton |
| Volume, cc | 10 |
| Weight, kg | 0.64 |
| Gasket set | GVHFM100 |
| Mounting bracket | MBHFM100 |
From Headline's process gas bulletin; ask us for current availability.
For the Guardian membrane separators in Headline's current catalogue, see Guardian membrane separators.
Flow tables for every element size and grade, including the 150 and 160 series, with a calculator.
The large stainless steel housings for process gas and liquids: the 150 and 160 series with 1 to 2 inch ports, rated to 100, 200 or 400 bar, with dimensions, volumes, weights and gasket options.
Frequently asked questions
Which Headline housing suits a process gas line of 1 to 2 inches?
The 150 series (51-230 elements, 1,500 cc) or the longer 160 series (51-476 elements, 2,700 cc), both in 316L with 1, 1 1/2 or 2 inch NPT ports, rated to 100 bar, 200 bar (HP) or 400 bar (VP).
Can the 150 and 160 series run above 200 °C?
Yes, to 450 °C with a high-temperature gasket, but the pressure rating falls above 200 °C. We confirm the rating at your temperature with Headline.
Are flanged or Monel housings available?
Headline offers a variety of flange connections and can make these housings in exotic materials such as Monel and Hastelloy. Ask us with the duty.
How much flow does a 150 or 160 housing pass?
At 7 bar and 0.15 bar pressure drop, a 150 with a grade 50 element passes about 302 Nm³/h of air and a 160 about 516 Nm³/h. The tables and the sizing calculator give the other grades and pressures.
Can I service a filter without breaking the pipework?
Yes. The 129, 170 and 137G-3 are installed bowl up with the drain in the head, so the bowl comes off by hand while the pipework stays connected.
Can I buy these in India?
Sarvesh Analytics in Pune, India, is the exclusive representative of Headline Filters for the Indian subcontinent. The 150 and 160 series are in Headline's current catalogue; ask us for price and availability of the others.