Headline Filters · Exclusive representative for India

Headline PTFE and PVDF housings for corrosive and reactive samples

When the sample attacks metal, or the gas you measure must not stick to the filter, these housings keep metal out of the wetted path. PTFE housings bring very low adsorption; all-PVDF K housings put chemical resistance first.

Headline PTFE and PVDF
Quick answer

Headline's PTFE and PVDF filter housings: 21 models in PTFE and plastic, rated up to 7 bar and 150 °C, with each model's pressure and temperature rating listed below.

Figures from the Headline Filters catalogue and brochures

About the series

PTFE housings

  • For high chemical resistance and low adsorption. P versions are all PTFE; PG versions have a Pyrex glass bowl to watch the element.
  • Use PVDF-bonded disposable elements for coalescing and particulate duty, or sintered PTFE elements for particulate and liquid filtration.
  • Viton O-rings are standard.

PVDF housings (K)

  • All PVDF with no metal contact surfaces, for applications where chemical resistance comes first.
  • Manual twist drain for liquid applications, or no drain for particulate.
  • Use only PVDF-bonded elements (K for particulate, C for coalescing) or PTFE elements, to keep the chemical resistance.

Models and ratings

ModelPortsDrainRatingElementBowlComparable to
120P1/8" NPT1/8" NPT150°C - 7 bar12-57-xxBalston 95T
120PG1/4" NPT1/8" NPT100°C - 7 bar12-57-xxTransparent
122P1/4" NPT1/4" NPT150°C - 7 bar12-57-xxBalston 95T, Finite T1R
122PG1/4" NPT1/8" NPT100°C - 7 bar12-57-xxTransparent
130P1/4" NPT1/4" NPT150°C - 7 bar25-64-xx
130PG1/4" NPT1/8" NPT100°C - 7 bar25-64-xxTransparent
132P1/2" NPT1/4" NPT150°C - 7 bar25-64-xx
132PG1/2" NPT1/8" NPT100°C - 7 bar25-64-xxTransparent
142P1/2" NPT1/4" NPT150°C - 7 bar25-178-xx
–Ask usAsk us
700K1/8" NPTNone120°C - 7 barAsk us
701K1/8" NPTManual120°C - 7 barAsk us
705K1/4" BSPPNone120°C - 7 barAsk us
705K1/4" NPTNone120°C - 7 barAsk us
710K1/4" NPTManual120°C - 7 barAsk us
720K1/8" NPTNone120°C - 7 barAsk us
721K1/8" NPTManual120°C - 7 barAsk us
725K1/4" NPTNone120°C - 7 barAsk us
730K1/4" NPTManual120°C - 7 barAsk us
750K1/4" NPTNone120°C - 7 barAsk us
751K1/4" NPTManual120°C - 7 barAsk us

Comparable parts are from Headline's published charts; see all Balston equivalents. Parker, Balston and Finite are registered trademarks of Parker-Hannifin Corporation. Headline Filters and Sarvesh Analytics are not affiliated with Parker-Hannifin; names and part numbers identify a comparable product only.

From the Headline Filters catalogue. Each model opens its own page.

Choosing a model

  • Port size. This series comes with 1/2" NPT, 1/4" BSPP, 1/4" NPT, 1/8" NPT ports. Match the sample line, or ask us about an adaptor.
  • Rating. Headline states each model's maximum temperature and pressure together: 100 °C at 7 bar; 120 °C at 7 bar; 150 °C at 7 bar. Check both against the worst case at the filter, not the normal operating point.
  • Drain. 14 of these 21 models have a drain or bypass port, for coalescing duty where liquid collects; the others are for particulate filtration of a gas that is already dry.
  • Bowl. 4 models have a transparent bowl, so you can watch the element and any liquid without opening the housing.

Elements

PVDF housings take only PVDF-bonded elements, K for particulate and C for coalescing, or sintered PTFE elements, to keep their chemical resistance. Headline bonded microfibre elements are rated by removal of 0.1 micron particles: Grade 40 above 99.9999 %, 50 above 99.99 %, 60 above 99.5 %, 70 above 95 % and 80 above 75 %. The standard epoxy binder and the PVDF binder (K, C) are rated to 150 °C; the silica binder (S, CS) to 500 °C and where solvents are present. Stainless steel mesh elements (1 to 200 micron) suit liquids and heavy dirt, and sintered PTFE elements (3, 10 or 20 micron) suit samples where only PTFE may be used. The element size for each model is in the table above, from Headline's brochures; replace xx with the grade, for example 25-64-50C.

Headline brochures

Headline's own brochures for these products, with dimensions and order codes.

All Headline brochures and application notes

Not sure which model?

The filter finder takes your duty, gas, pressure, temperature and port and returns the Headline housings rated for it, with the element grade and binder.

Find your filter

Frequently asked questions

Which models are in the Headline PTFE and PVDF?

21 models: 120P, 120PG, 122P, 122PG, 130P, 130PG, 132P, 132PG, 142P, , 700K, 701K, 705K, 705K, 710K, 720K, 721K, 725K, 730K, 750K, 751K.

What pressure and temperature are they rated for?

From 7 to 7 bar and 100 to 150 °C, by model; each model's maximum temperature and pressure are stated together in the table above.

Which element fits these housings?

From Headline's brochures: 120P, 120PG, 122P, 122PG take 12-57 elements; 130P, 130PG, 132P, 132PG take 25-64 elements; 142P take 25-178 elements. Replace xx in the part number with the grade, for example 25-64-50C. For models not listed, we confirm the size.

Can I buy them in India?

Yes. Sarvesh Analytics supplies the full Headline range as its exclusive representative for the Indian subcontinent. Ask for price and lead time on the models you need.