Headline Filters · Exclusive representative for India

Headline heatable filter housings for hot gas analysis

Housings made to be heated, so a hot, wet sample stays above its dew point while it is filtered: diesel exhaust at 200 °C is Headline's own example. The bayonet bowl lets you change the element in seconds at operating temperature.

Headline heatable
Quick answer

Headline's heatable filter housings: 6 models in stainless steel 316, rated up to 2 bar and 200 °C, with each model's pressure and temperature rating listed below.

Figures from the Headline Filters catalogue and brochures

About the series

Heatable housings (H130, H140)

  • Made for hot gas analysis, such as diesel exhaust at 200 °C, and heated by any external heater.
  • The bayonet bowl lets the element be changed in seconds, even at operating temperature.
  • H130 and H140 have both ports in the base so the whole housing can be heated; S and ST versions have side ports; T versions seal the element with a tie-rod and retainer.

Models and ratings

ModelPortsDrainRatingElement
H1301/4" NPT–200°C - 2 bar25-64-xxS
H130-ST1/4" NPT–200°C - 2 bar25-64-xxS
H130T1/4" NPT–200°C - 2 bar25-64-xxS
H1401/4" NPT–200°C - 2 bar25-178-xxS
H140-ST1/4" NPT–200°C - 2 bar25-178-xxS
H140T1/4" NPT–200°C - 2 bar25-178-xxS

From the Headline Filters catalogue. Each model opens its own page.

Choosing a model

  • Port size. This series comes with 1/4" NPT ports. Match the sample line, or ask us about an adaptor.
  • Rating. Headline states each model's maximum temperature and pressure together: 200 °C at 2 bar. Check both against the worst case at the filter, not the normal operating point.

Elements

Headline bonded microfibre elements are rated by removal of 0.1 micron particles: Grade 40 above 99.9999 %, 50 above 99.99 %, 60 above 99.5 %, 70 above 95 % and 80 above 75 %. The standard epoxy binder and the PVDF binder (K, C) are rated to 150 °C; the silica binder (S, CS) to 500 °C and where solvents are present. Stainless steel mesh elements (1 to 200 micron) suit liquids and heavy dirt, and sintered PTFE elements (3, 10 or 20 micron) suit samples where only PTFE may be used. The element size for each model is in the table above, from Headline's brochures; replace xx with the grade, for example 25-64-50C.

Headline brochures

Headline's own brochures for these products, with dimensions and order codes.

All Headline brochures and application notes

Not sure which model?

The filter finder takes your duty, gas, pressure, temperature and port and returns the Headline housings rated for it, with the element grade and binder.

Find your filter

Frequently asked questions

Which models are in the Headline heatable?

6 models: H130, H130-ST, H130T, H140, H140-ST, H140T.

What pressure and temperature are they rated for?

From 2 to 2 bar and 200 to 200 °C, by model; each model's maximum temperature and pressure are stated together in the table above.

Which element fits these housings?

From Headline's brochures: H130, H130-ST, H130T take 25-64 (S type) elements; H140, H140-ST, H140T take 25-178 (S type) elements. Replace xx in the part number with the grade, for example 25-64-50C. For models not listed, we confirm the size.

Can I buy them in India?

Yes. Sarvesh Analytics supplies the full Headline range as its exclusive representative for the Indian subcontinent. Ask for price and lead time on the models you need.