Headline Filters · Exclusive representative for India

Headline 130 and 140 series stainless steel filter housings

The versatile Headline housings for process analysers, CNG, high-pressure gas, supercritical CO2, and food and dairy duty. Weld-free 316L, NACE compliant, 100 bar as standard, 200 bar in HP and 400 bar in VP versions.

Headline 130 and 140 series
Quick answer

Headline's 130 and 140 series filter housings: 29 models, rated up to 400 bar and 200 °C, with each model's pressure and temperature rating listed below. Weld-free 316L, compliant with NACE MR0175 and MR0103.

Figures from the Headline Filters catalogue and brochures

About the series

130 and 140 series

  • Versatile housings for process analysers, CNG, high-pressure gas, supercritical CO2, and food and dairy processes; 110 to 320 cc internal volume.
  • Weld-free 316L, compliant with NACE MR0175 and MR0103.
  • Two-port models (134, 136, 144, 146) are for particulate filtration; three-port models (130, 132, 133, 140, 142, 143) for coalescing and bypass.
  • HP versions are rated to 200 bar and VP versions to 400 bar, with a small internal volume that limits carry-over at start-up. S versions have a PTFE seal and are the only ones that take a high-temperature gasket.

Models and ratings

ModelPortsDrainRatingElementComparable to
1301/4" NPT1/4" NPT200°C - 100 bar25-64-xxBalston 33S6-1/4"
130HP1/4" NPT1/4" NPT200°C - 200 bar25-64-xx
130VP1/4" NPT1/4" NPT200°C - 400 bar25-64-xx
1321/2" NPT1/4" NPT200°C - 100 bar25-64-xx
132-38751/2" BSPP1/4" NPT200°C - 100 bar25-64-xx
132HP1/2" NPT1/4" NPT200°C - 200 bar25-64-xx
132VP1/2" NPT1/4" NPT200°C - 400 bar25-64-xx
1331/2" NPT1/2" NPT200°C - 100 bar25-64-xx
1341/4" NPTNone200°C - 100 bar25-64-xx
134HP1/4" NPTNone200°C - 200 bar25-64-xx
134S1/4" NPTNone200°C - 100 bar25-64-xxBalston A34
134VP1/4" NPTNone200°C - 400 bar25-64-xx
1361/2" NPTNone200°C - 100 bar25-64-xx
136HP1/2" NPTNone200°C - 200 bar25-64-xx
136VP1/2" NPTNone200°C - 400 bar25-64-xx
1401/4" NPT1/4" NPT200°C - 100 bar25-178-xxBalston 41S6-1/4"
140HP1/4" NPT1/4" NPT200°C - 200 bar25-178-xx
140VP1/4" NPT1/4" NPT200°C - 400 bar25-178-xx
1421/2" NPT1/4" NPT200°C - 100 bar25-178-xxBalston 41S6-1/2"
142HP1/2" NPT1/4" NPT200°C - 200 bar25-178-xx
142VP1/2" NPT1/4" NPT200°C - 400 bar25-178-xx
1431/2" NPT1/2" NPT200°C - 100 bar25-178-xx
143HP1/2" NPT1/2" NPT200°C - 200 bar25-178-xx
1441/4" NPTNone200°C - 100 bar25-178-xx
144HP1/4" NPTNone200°C - 200 bar25-178-xx
144VP1/4" NPTNone200°C - 400 bar25-178-xx
1461/2" NPTNone200°C - 100 bar25-178-xx
146HP1/2" NPTNone200°C - 200 bar25-178-xx
146VP1/2" NPTNone200°C - 400 bar25-178-xx

Comparable parts are from Headline's published charts; see all Balston equivalents. Parker, Balston and Finite are registered trademarks of Parker-Hannifin Corporation. Headline Filters and Sarvesh Analytics are not affiliated with Parker-Hannifin; names and part numbers identify a comparable product only.

From the Headline Filters catalogue. Each model opens its own page.

Choosing a model

  • Port size. This series comes with 1/2" BSPP, 1/2" NPT, 1/4" NPT ports. Match the sample line, or ask us about an adaptor.
  • Rating. Headline states each model's maximum temperature and pressure together: 200 °C at 100 bar; 200 °C at 200 bar; 200 °C at 400 bar. Check both against the worst case at the filter, not the normal operating point.
  • Drain. 16 of these 29 models have a drain or bypass port, for coalescing duty where liquid collects; the others are for particulate filtration of a gas that is already dry.

Elements

Headline bonded microfibre elements are rated by removal of 0.1 micron particles: Grade 40 above 99.9999 %, 50 above 99.99 %, 60 above 99.5 %, 70 above 95 % and 80 above 75 %. The standard epoxy binder and the PVDF binder (K, C) are rated to 150 °C; the silica binder (S, CS) to 500 °C and where solvents are present. Stainless steel mesh elements (1 to 200 micron) suit liquids and heavy dirt, and sintered PTFE elements (3, 10 or 20 micron) suit samples where only PTFE may be used. The element size for each model is in the table above, from Headline's brochures; replace xx with the grade, for example 25-64-50C.

Headline brochures

Headline's own brochures for these products, with dimensions and order codes.

All Headline brochures and application notes

Not sure which model?

The filter finder takes your duty, gas, pressure, temperature and port and returns the Headline housings rated for it, with the element grade and binder.

Find your filter

Frequently asked questions

Which models are in the Headline 130 and 140 series?

29 models: 130, 130HP, 130VP, 132, 132-3875, 132HP, 132VP, 133, 134, 134HP, 134S, 134VP, 136, 136HP, 136VP, 140, 140HP, 140VP, 142, 142HP, 142VP, 143, 143HP, 144, 144HP, 144VP, 146, 146HP, 146VP.

What pressure and temperature are they rated for?

From 100 to 400 bar and 200 to 200 °C, by model; each model's maximum temperature and pressure are stated together in the table above.

Which element fits these housings?

From Headline's brochures: 130, 130HP, 130VP, 132, 132-3875, 132HP and others take 25-64 elements; 140, 140HP, 140VP, 142, 142HP, 142VP and others take 25-178 elements. Replace xx in the part number with the grade, for example 25-64-50C. For models not listed, we confirm the size.

Are they suitable for sour gas?

They are weld-free 316L stainless steel and compliant with NACE MR0175 and MR0103, the standards for sour (H2S) service. Confirm the rating at your temperature with us.

Can I buy them in India?

Yes. Sarvesh Analytics supplies the full Headline range as its exclusive representative for the Indian subcontinent. Ask for price and lead time on the models you need.