Headline 150 and 160 series high-flow filter housings

Large weld-free 316L housings for gas and liquid at higher flows, with 1, 1 1/2 and 2 inch ports and a 1/4 inch drain. NACE compliant, 100 bar as standard, 200 bar in HP and 400 bar in VP versions.

Headline 150 and 160 series
Quick answer

Headline's 150 and 160 series filter housings: 18 models, rated up to 400 bar and 200 °C, with each model's pressure and temperature rating listed below. Weld-free 316L, compliant with NACE MR0175 and MR0103.

Figures from the Headline Filters catalogue and brochures

About the series

150 and 160 series

  • For gas and liquid processes at higher flow: 1500 cc (150 series) or 2700 cc (160 series) internal volume, 1 to 2 inch ports and a 1/4 inch drain.
  • Weld-free 316L, compliant with NACE MR0175 and MR0103. HP versions are rated to 200 bar and VP versions to 400 bar.
  • For liquid service, fit a stainless steel element from 1 to 200 micron.

Models and ratings

ModelPortsDrainRatingElement
1501" NPT1/4" NPT200°C - 100 bar51-230-xx
150HP1" NPT1/4" NPT200°C - 200 bar51-230-xx
150VP1" NPT1/4" NPT200°C - 400 bar51-230-xx
1511 1/2" NPT1/4" NPT200°C - 100 bar51-230-xx
151HP1 1/2" NPT1/4" NPT200°C - 200 bar51-230-xx
151VP1 1/2" NPT1/4" NPT200°C - 400 bar51-230-xx
1522" NPT1/4" NPT200°C - 100 bar51-230-xx
152HP2" NPT1/4" NPT200°C - 200 bar51-230-xx
152VP2" NPT1/4" NPT200°C - 400 bar51-230-xx
1601" NPT1/4" NPT200°C - 100 bar51-476-xx
160HP1" NPT1/4" NPT200°C - 200 bar51-476-xx
160VP1" NPT1/4" NPT200°C - 400 bar51-476-xx
1611 1/2" NPT1/4" NPT200°C - 100 bar51-476-xx
161HP1 1/2" NPT1/4" NPT200°C - 200 bar51-476-xx
161VP1 1/2" NPT1/4" NPT200°C - 400 bar51-476-xx
1622" NPT1/4" NPT200°C - 100 bar51-476-xx
162HP2" NPT1/4" NPT200°C - 200 bar51-476-xx
162VP2" NPT1/4" NPT200°C - 400 bar51-476-xx

From the Headline Filters catalogue. Each model opens its own page.

Choosing a model

  • Port size. This series comes with 1 1/2" NPT, 1" NPT, 2" NPT ports. Match the sample line, or ask us about an adaptor.
  • Rating. Headline states each model's maximum temperature and pressure together: 200 °C at 100 bar; 200 °C at 200 bar; 200 °C at 400 bar. Check both against the worst case at the filter, not the normal operating point.

Elements

Headline bonded microfibre elements are rated by removal of 0.1 micron particles: Grade 40 above 99.9999 %, 50 above 99.99 %, 60 above 99.5 %, 70 above 95 % and 80 above 75 %. The standard epoxy binder and the PVDF binder (K, C) are rated to 150 °C; the silica binder (S, CS) to 500 °C and where solvents are present. Stainless steel mesh elements (1 to 200 micron) suit liquids and heavy dirt, and sintered PTFE elements (3, 10 or 20 micron) suit samples where only PTFE may be used. The element size for each model is in the table above, from Headline's brochures; replace xx with the grade, for example 25-64-50C.

Dimensions, weights and spares

150 series

Specification150151152150HP151HP152HP150VP151VP152VP
Port, NPT1"1 1/2"2"1"1 1/2"2"1"1 1/2"2"
Drain, NPT1/4"1/4"1/4"1/4"1/4"1/4"1/4"1/4"1/4"
Maximum pressure, bar100100100200200200400400400
Maximum temperature, °C200200200200200200200200200
A, mm303041385252365052
B, mm110110115120130130150150164
C, mm382382402363393393411434434
D, mm247247247247247247247247247
Volume, cc150015001500150015001500150015001500
Weight, kg99917.317.317.3222222
Standard gasket setGV150GV150GV150GV150HPGV150HPGV150HPGV150VPGV150VPGV150VP
PTFE gasketGP150GP150GP150GP150HPGP150HPGP150HPGP150VPGP150VPGP150VP
Support coreSC150SC150SC150SC150SC150SC150SC150SC150SC150
Mounting bracketMB150MB150MB150MB150MB150MB150MB150VPMB150VPMB150VP
Glass fibre element51-230-xx51-230-xx51-230-xx51-230-xx51-230-xx51-230-xx51-230-xx51-230-xx51-230-xx
Stainless steel elementSS-150-xxSS-150-xxSS-150-xxSS-150-xxSS-150-xxSS-150-xxSS-150-xxSS-150-xxSS-150-xx
PTFE elementPT-150-xxPT-150-xxPT-150-xxPT-150-xxPT-150-xxPT-150-xxPT-150-xxPT-150-xxPT-150-xx

160 series

Specification160161162160HP161HP162HP160VP161VP162VP
Port, NPT1"1 1/2"2"1"1 1/2"2"1"1 1/2"2"
Drain, NPT1/4"1/4"1/4"1/4"1/4"1/4"1/4"1/4"1/4"
Maximum pressure, bar100100100200200200400400400
Maximum temperature, °C200200200200200200200200200
A, mm303041385252365052
B, mm110110115120130130150150164
C, mm619619648608639639657680680
D, mm492492492492492492492492492
Volume, cc270027002700270027002700270027002700
Weight, kg181818242428282828
Standard gasket setGV160GV160GV160GV160HPGV160HPGV160HPGV160VPGV160VPGV160VP
PTFE gasketGP160GP160GP160GP160HPGP160HPGP160HPGP160VPGP160VPGP160VP
Support coreSC160SC160SC160SC160SC160SC160SC160SC160SC160
Mounting bracketMB150MB150MB150MB150MB150MB150MB150VPMB150VPMB150VP
Glass fibre element51-476-xx51-476-xx51-476-xx51-476-xx51-476-xx51-476-xx51-476-xx51-476-xx51-476-xx
Stainless steel elementSS-160-xxSS-160-xxSS-160-xxSS-160-xxSS-160-xxSS-160-xxSS-160-xxSS-160-xxSS-160-xx
PTFE elementPT-160-xxPT-160-xxPT-160-xxPT-160-xxPT-160-xxPT-160-xxPT-160-xxPT-160-xxPT-160-xx
  • Above 200 °C the pressure rating is reduced; Headline gives the exact rating for a specific temperature, and we confirm it with them.
  • 200 °C is the limit with standard seals. A high-temperature gasket takes the housing to 450 °C.
  • Entirely 316L stainless steel, with Viton or PTFE seals, designed to BS 5500. For liquids and gases, and high-flow corrosive duty in 1 to 2 inch lines.
  • A variety of flange connections is available, and the housings can be made in exotic materials such as Monel and Hastelloy.
  • Replace xx with the grade, for example 51-230-50C, SS-150-25 or PT-150-03.

Flow rates

From Headline bulletin HFL203. Flow is generally proportional to the pressure drop. For other line pressures, grades or gases, use the sizing calculator.

150 series (51-230 elements)

Line pressure, bar gGrade 30Grade 40Grade 50Grade 60Grade 70
012223889101
1244476178202
23666113268303
34883151357404
459110189446505
571133227535607
683155265624708
795177302714809
8107199340803910
91192213788921010
101312434169811110
Water, l/h21440070517701910

Air at 20 °C in Nm³/h, and water in l/h, with a 0.15 bar pressure drop.

160 series (51-476 elements)

Line pressure, bar gGrade 30Grade 40Grade 50Grade 60Grade 70
0254465107114
14987129213228
274131194320341
399175258426455
4123219323533569
5148262387640683
6172306152*746797
7197350516853911
82223945819601020
9246497*64610701140
1027148171011701250
Water, l/h410780120020702240

Air at 20 °C in Nm³/h, and water in l/h, with a 0.15 bar pressure drop. * Printed as 152 for grade 50 at 6 bar; the bulletin's own s.c.f.m. figure gives 452 Nm³/h, which the calculator uses. * Printed as 497 for grade 40 at 9 bar; the bulletin's own s.c.f.m. figure gives 437 Nm³/h, which the calculator uses.

Other process gas products, including bowl-up analyser housings and stainless adsorption housings, are on the process gas filters page.

Headline brochures

Headline's own brochures for these products, with dimensions and order codes.

All Headline brochures and application notes

Not sure which model?

The filter finder takes your duty, gas, pressure, temperature and port and returns the Headline housings rated for it, with the element grade and binder.

Find your filter

Frequently asked questions

Which models are in the Headline 150 and 160 series?

18 models: 150, 150HP, 150VP, 151, 151HP, 151VP, 152, 152HP, 152VP, 160, 160HP, 160VP, 161, 161HP, 161VP, 162, 162HP, 162VP.

What pressure and temperature are they rated for?

From 100 to 400 bar and 200 to 200 °C, by model; each model's maximum temperature and pressure are stated together in the table above.

Which element fits these housings?

From Headline's brochures: 150, 150HP, 150VP, 151, 151HP, 151VP and others take 51-230 elements; 160, 160HP, 160VP, 161, 161HP, 161VP and others take 51-476 elements. Replace xx in the part number with the grade, for example 25-64-50C. For models not listed, we confirm the size.

Are they suitable for sour gas?

They are weld-free 316L stainless steel and compliant with NACE MR0175 and MR0103, the standards for sour (H2S) service. Confirm the rating at your temperature with us.

Can I buy them in India?

Yes. Sarvesh Analytics supplies the full Headline range as its exclusive representative for the Indian subcontinent. Ask for price and lead time on the models you need.

Talk to an applications engineer

Send the gas, range, pressure, temperature and area classification.

Request a quoteAsk an engineer: +91 94 2300 4179Sales; support +91 94 2300 4178Download the Headline brochureFilters for Process Gases, PDF 200 KB