Headline Filters · Application note

Filters for stack emission and ambient monitoring

Stack gas is hot, wet, dusty and often acidic, and an emission analyser has to read it for years with little attention. The filters decide how often someone climbs the stack. Headline lists the elements, housings and membranes below for ambient, combustion and pollution monitoring equipment.

Headline filters for stack emission and ambient monitoring
Quick answer

Headline's range of stack and emission monitoring filters runs to 123 products in these families: 110 and 120 series, low-pressure stainless steel series, in-line filters (IL), 200 series aluminium housings and 300 series aluminium coalescing housings.

Figures from the Headline Filters catalogue and brochures

What the filters face

  • Heat. Silica-bonded elements (S and CS) are completely inorganic and rated to 500 °C, so they can sit in a heated probe or heated filter housing.
  • Acid gases and condensate. PVDF-bonded elements (K and C) resist corrosive gases up to 150 °C. Keep the sample above its dew point until the cooler, then coalesce what is left.
  • Liquid carry-over. A Guardian membrane separator at the analyser inlet stops liquid from a cooler upset reaching the cells. Headline does not recommend it for hydrofluoric acid.
  • Ambient monitors. Disposable in-line filters protect small pumps and sensors in portable and ambient instruments.

With a Sarvesh system

  • The SP-300 heated probe filters the gas at the stack, the i-Cons conditioner cools and dries it, and Headline elements protect the analysers. SGI-320 packages the whole chain for stack emission monitoring.

Headline products for this duty

Headline lists these 123 products for this application, grouped by family. Open a family to see every model; each links to its card with ports and rating.

110 and 120 series

19 products, to 700 bar
ModelPortsRatingOptions
1101/8" NPT200°C - 340 bar1/8" NPT drain
110HP1/8" NPT200°C - 700 bar1/8" NPT drain
1121/4" NPT200°C - 340 bar1/4" NPT drain
112HP1/4" NPT200°C - 700 bar1/4" NPT drain
1141/8" NPT200°C - 340 barNo drain
114HP1/8" NPT200°C - 700 barNo drain
1161/4" NPT200°C - 340 barNo drain
116HP1/4" NPT200°C - 700 barNo drain
1201/8" NPT200°C - 340 bar1/8" NPT drain
120B1/8" NPT200°C - 340 bar1/8" NPT drain
120HP1/8" NPT200°C - 700 bar1/8" NPT drain
120S1/8" NPT200°C - 340 bar1/8" NPT drain
1221/4" NPT200°C - 340 bar1/4" NPT drain
122B1/4" NPT200°C - 340 bar1/4" NPT drain
122HP1/4" NPT200°C - 700 bar1/4" NPT drain
1241/8" NPT200°C - 340 barNo drain
124HP1/8" NPT200°C - 700 barNo drain
1261/4" NPT200°C - 340 barNo drain
126HP1/4" NPT200°C - 700 barNo drain

Low-pressure stainless steel series

12 products, to 7 bar
ModelPortsRatingOptions
1171/4" NPT100°C - 7 bar1/8" NPT drain
117G1/4" NPT100°C - 7 bar1/8" NPT drain
1271/4" NPT100°C - 7 bar1/8" NPT drain
127G1/4" NPT100°C - 7 bar1/8" NPT drain
1371/4" NPT100°C - 7 bar1/4" NPT drain
137G1/4" NPT100°C - 7 bar1/4" NPT drain
1381/2" NPT100°C - 7 bar1/4" NPT drain
138G1/2" NPT100°C - 7 bar1/4" NPT drain
1471/4" NPT100°C - 7 bar1/4" NPT drain
147G1/4" NPT100°C - 7 bar1/4" NPT drain
1481/2" NPT100°C - 7 bar1/4" NPT drain
148G1/2" NPT100°C - 7 bar1/4" NPT drain

In-line filters (IL)

4 products, to 340 bar
ModelPortsRatingOptions
116IL1/4" NPT200°C - 340 bar–
126IL1/4" NPT200°C - 340 barCell Filler
136IL1/2" NPT200°C - 100 bar–
146IL1/2" NPT200°C - 100 barCell Filler

200 series aluminium housings

27 products, to 16 bar
ModelPortsRatingOptions
2001/8" NPT50°C - 10 barNo drain
200A1/8" NPT120°C - 16 barBrass
2031/4" NPT50°C - 10 barNo drain
203A1/4" NPT120°C - 16 barNo drain
203AL1/8" NPT120°C - 16 barBrass
2101/8" NPT50°C - 10 barManual
210A1/8" NPT50°C - 10 barManual
210AL1/8" NPT120°C - 16 barBrass
2131/4" NPT50°C - 10 barManual
213A1/4" NPT120°C - 16 barBrass
213AL1/4" NPT120°C - 16 barBrass
2231/4" NPT50°C - 10 barNo drain
223A1/4" NPT120°C - 16 barNo drain
2251/2" NPT50°C - 10 barNo drain
225A1/2" NPT120°C - 16 barNo drain
2301/4" NPT50°C - 10 barManual
230A1/4" NPT120°C - 16 barBrass
2331/2" NPT50°C - 10 barManual
233A1/2" NPT120°C - 16 barBrass
2431/4" NPT50°C - 10 barNo drain
243A1/4" NPT120°C - 16 barNo drain
2451/2" NPT50°C - 10 barNo drain
245A1/2" NPT120°C - 16 barNo drain
2501/4" NPT50°C - 10 barManual
250A1/4" NPT120°C - 16 barBrass
2531/2" NPT50°C - 10 barManual
253A1/2" NPT120°C - 16 barBrass

300 series aluminium coalescing housings

36 products, to 16 bar
ModelPortsRatingOptions
3101/8" NPT50°C - 10 barManual
310A1/8" NPT120°C - 16 barBrass
3151/4" NPT50°C - 10 barManual
315A1/4" NPT120°C - 16 barBrass
3601/4" NPT50°C - 10 barManual
360A1/4" NPT120°C - 16 barBrass
360AF1/4" NPT120°C - 16 barAuto float
360AFI1/4" NPT120°C - 10 barAuto float
360AI1/4" NPT120°C - 10 barBrass
360F1/4" NPT50°C - 10 barAuto float
360FI1/4" NPT50°C - 10 barAuto float
360I1/4" NPT50°C - 10 barManual
3651/2" NPT50°C - 10 barManual
365A1/2" NPT120°C - 16 barBrass
365AF1/2" NPT120°C - 16 barAuto float
365AFI1/2" NPT120°C - 10 barAuto float
365AI1/2" NPT120°C - 10 barBrass
365F1/2" NPT50°C - 10 barAuto float
365FI1/2" NPT50°C - 10 barAuto float
365I1/2" NPT50°C - 10 barManual
3701/4" NPT50°C - 10 barManual
370A1/4" NPT120°C - 16 barBrass
370AF1/4" NPT120°C - 16 barAuto float
370AFI1/4" NPT120°C - 10 barAuto float
370AI1/4" NPT120°C - 10 barBrass
370F1/4" NPT50°C - 10 barAuto float
370FI1/4" NPT50°C - 10 barAuto float
370I1/4" NPT50°C - 10 barManual
3751/2" NPT50°C - 10 barManual
375A1/2" NPT120°C - 16 barBrass
375AF1/2" NPT120°C - 16 barAuto float
375AFI1/2" NPT120°C - 10 barAuto float
375AI1/2" NPT120°C - 10 barBrass
375F1/2" NPT50°C - 10 barAuto float
375FI1/2" NPT50°C - 10 barAuto float
375I1/2" NPT50°C - 10 barManual

Guardian membrane separators

10 products, to 150 bar
ModelPortsRatingOptions
GMS1001/4" NPT100°C - 100 barM2- High Flow
GMS1051/4" NPT100°C - 100 barM2- High Flow
GMS1051/8" NPT100°C - 100 barM1- Low Flow
GMS105P1/4" NPT100°C - 7 barM2- High Flow
GMS1221/4" NPT100°C - 100 barM2- High Flow
GMS1301/4" NPT100°C - 100 barM2- High Flow
GMS1701/4" NPT100°C - 150 barM2- High Flow
GMS2051/4" NPT100°C - 100 barM2- High Flow
GMS205P1/4" NPT100°C - 7 barM2- High Flow
M2H–––

Filter elements

10 products
ModelPortsRatingOptions
10-37-60K––Grade 60K
12-32.7-70–––
12-43.5-60K––Grade 60K
16-41-60––Grade 60
25-64-70CS–––
Coalescing Glass Fibre Filter Element (PVDF - Corrosive Applications)––Grade 40C, Grade 50C, Grade 60C, Grade 70C, Grade 80C, Grade 50CR
Coalescing Glass Fibre Filter Element (Silica - Up to 500°C)––Grade 40CS, Grade 50CS, Grade 60CS, Grade 70CS, Grade 80CS
Particulate Glass Fibre Filter Element (Epoxy - Standard)––Grade 40, Grade 50, Grade 60, Grade 70, Grade 80
Particulate Glass Fibre Filter Element (PVDF - Corrosive Applications)––Grade 40K, Grade 50K, Grade 60K, Grade 70K, Grade 80K
Particulate Glass Fibre Filter Element (Silica - up to 500°C)––Grade 40S, Grade 50S, Grade 60S, Grade 70S, Grade 80S

Disposable in-line filters and adsorbers

5 products, to 8.5 bar
ModelPortsRatingOptions
DIA-BN6.3mm110°C @ 0bar - 50°C @ 8.5barActivated Carbon, Silica Gel, Molecular Sieve 13X, Potassium Permanganate, Mixed Bases, Molecular Sieve 4A
DIA-IN6.3mm110°C @ 0bar - 50°C @ 7barActivated Carbon, Silica Gel, Potassium Permanganate, Molecular Sieve 13X, Molecular Sieve 4A, Mixed Bases
DIA-LN12.7mm110°C @ 0bar - 50°C @ 7barActivated Carbon, Silica Gel, Potassium Permanganate, Mixed Bases, Molecular Sieve 13X, Molecular Sieve 4A
DIA-LN-11/4" NPT (male)110°C @ 0bar - 50°C @ 7barActivated Carbon, Silica Gel
DIA-MN6.3mm110°C @ 0bar - 50°C @ 8.5barActivated Carbon, Silica Gel, Molecular Sieve 13X, Mixed Bases, Molecular Sieve 4A, Potassium Permanganate
Find the exact model

The filter finder takes your gas, pressure, temperature and port and returns the Headline housings rated for it, with the element grade and binder.

Find your filter
Headline brochure: Filters for Instrumentation and Gas Analysis

The main Headline catalogue for sample systems: bonded microfibre, stainless steel and PTFE elements in industry-standard sizes and grades, and the stainless steel, PTFE, PVDF, plastic and aluminium housings that hold them, with dimensions and order codes.

Download the PDF 32 pages, 1.3 MB

Frequently asked questions

Which element for hot flue gas?

A silica-bonded element, S for particulate or CS for coalescing, rated to 500 °C. The housing must be rated for the temperature too.

Which element for acid gases?

A PVDF-bonded element, K for particulate or C for coalescing, up to 150 °C, in a housing whose wetted parts suit the gas.

Do you claim any regulatory approval for these filters?

No. Filters are components of a monitoring system; we confirm the materials and grades against your sample and duty.