Headline Filters · Application note

Filters for gas analyser sample systems

A gas analyser is only as reliable as the sample that reaches it. Particles block flow restrictors and coat sensors; oil and water aerosols poison cells and fog optics. Headline's sample conditioning range covers every filter position in the sample path, and Sarvesh builds the same filters into its own sample systems.

Headline filters for gas analyser sample systems
Quick answer

Headline's range of gas analyser sample filters runs to 114 products in these families: 110 and 120 series, 130 and 140 series, 150 and 160 series, low-pressure stainless steel series and in-line filters (IL).

Figures from the Headline Filters catalogue and brochures

Where the filters go

  • At the take-off. A probe filter keeps the bulk of the dust in the process. For hot, wet gas the filter is heated so nothing condenses on it.
  • Near the analyser, if response time matters. A fast loop filter sits close to the analyser with a large bypass flow that keeps the element clean; the analyser draws filtered sample from its side port.
  • After the cooler. A coalescing filter takes out the fine aerosols a cooler leaves behind. Use a three-port housing so the liquid drains.
  • At the analyser inlet. A Guardian membrane separator is the last barrier: gas passes, liquid does not.

Choosing the housing

  • Small internal volume keeps the analyser's response fast: the 110 and 120 series hold 20 to 30 cc. Weld-free 316L housings are compliant with NACE MR0175 and MR0103 for sour gas.
  • For corrosive samples or gases that must not stick to the filter, use PTFE or all-PVDF housings, with PVDF-bonded or PTFE elements.
  • Two-port housings are for particulate filtration of a dry gas; three-port housings carry coalescing and bypass.

Headline products for this duty

Headline lists these 114 products for this application, grouped by family. Open a family to see every model; each links to its card with ports and rating.

110 and 120 series

22 products, to 700 bar
ModelPortsRatingOptions
1101/8" NPT200°C - 340 bar1/8" NPT drain
110HP1/8" NPT200°C - 700 bar1/8" NPT drain
1121/4" NPT200°C - 340 bar1/4" NPT drain
112HP1/4" NPT200°C - 700 bar1/4" NPT drain
1141/8" NPT200°C - 340 barNo drain
114HP1/8" NPT200°C - 700 barNo drain
1161/4" NPT200°C - 340 barNo drain
116HP1/4" NPT200°C - 700 barNo drain
1201/8" NPT200°C - 340 bar1/8" NPT drain
120B1/8" NPT200°C - 340 bar1/8" NPT drain
120HP1/8" NPT200°C - 700 bar1/8" NPT drain
120S1/8" NPT200°C - 340 bar1/8" NPT drain
1221/4" NPT200°C - 340 bar1/4" NPT drain
122 SilcoNert1/4" NPT––
122B1/4" NPT200°C - 340 bar1/4" NPT drain
122HP1/4" NPT200°C - 700 bar1/4" NPT drain
122S1/4" NPT200°C - 340 bar1/4" NPT drain
1241/8" NPT200°C - 340 barNo drain
124HP1/8" NPT200°C - 700 barNo drain
1261/4" NPT200°C - 340 barNo drain
126HP1/4" NPT200°C - 700 barNo drain
126S1/4" NPT200°C - 340 barNo drain

130 and 140 series

29 products, to 400 bar
ModelPortsRatingOptions
1301/4" NPT200°C - 100 bar1/4" NPT drain
130HP1/4" NPT200°C - 200 bar1/4" NPT drain
130VP1/4" NPT200°C - 400 bar1/4" NPT drain
1321/2" NPT200°C - 100 bar1/4" NPT drain
132-38751/2" BSPP200°C - 100 bar1/4" NPT drain
132HP1/2" NPT200°C - 200 bar1/4" NPT drain
132VP1/2" NPT200°C - 400 bar1/4" NPT drain
1331/2" NPT200°C - 100 bar1/2" NPT drain
1341/4" NPT200°C - 100 barNo drain
134HP1/4" NPT200°C - 200 barNo drain
134S1/4" NPT200°C - 100 barNo drain
134VP1/4" NPT200°C - 400 barNo drain
1361/2" NPT200°C - 100 barNo drain
136HP1/2" NPT200°C - 200 barNo drain
136VP1/2" NPT200°C - 400 barNo drain
1401/4" NPT200°C - 100 bar1/4" NPT drain
140HP1/4" NPT200°C - 200 bar1/4" NPT drain
140VP1/4" NPT200°C - 400 bar1/4" NPT drain
1421/2" NPT200°C - 100 bar1/4" NPT drain
142HP1/2" NPT200°C - 200 bar1/4" NPT drain
142VP1/2" NPT200°C - 400 bar1/4" NPT drain
1431/2" NPT200°C - 100 bar1/2" NPT drain
143HP1/2" NPT200°C - 200 bar1/2" NPT drain
1441/4" NPT200°C - 100 barNo drain
144HP1/4" NPT200°C - 200 barNo drain
144VP1/4" NPT200°C - 400 barNo drain
1461/2" NPT200°C - 100 barNo drain
146HP1/2" NPT200°C - 200 barNo drain
146VP1/2" NPT200°C - 400 barNo drain

150 and 160 series

18 products, to 400 bar
ModelPortsRatingOptions
1501" NPT200°C - 100 bar1/4" NPT drain
150HP1" NPT200°C - 200 bar1/4" NPT drain
150VP1" NPT200°C - 400 bar1/4" NPT drain
1511 1/2" NPT200°C - 100 bar1/4" NPT drain
151HP1 1/2" NPT200°C - 200 bar1/4" NPT drain
151VP1 1/2" NPT200°C - 400 bar1/4" NPT drain
1522" NPT200°C - 100 bar1/4" NPT drain
152HP2" NPT200°C - 200 bar1/4" NPT drain
152VP2" NPT200°C - 400 bar1/4" NPT drain
1601" NPT200°C - 100 bar1/4" NPT drain
160HP1" NPT200°C - 200 bar1/4" NPT drain
160VP1" NPT200°C - 400 bar1/4" NPT drain
1611 1/2" NPT200°C - 100 bar1/4" NPT drain
161HP1 1/2" NPT200°C - 200 bar1/4" NPT drain
161VP1 1/2" NPT200°C - 400 bar1/4" NPT drain
1622" NPT200°C - 100 bar1/4" NPT drain
162HP2" NPT200°C - 200 bar1/4" NPT drain
162VP2" NPT200°C - 400 bar1/4" NPT drain

Low-pressure stainless steel series

12 products, to 7 bar
ModelPortsRatingOptions
1171/4" NPT100°C - 7 bar1/8" NPT drain
117G1/4" NPT100°C - 7 bar1/8" NPT drain
1271/4" NPT100°C - 7 bar1/8" NPT drain
127G1/4" NPT100°C - 7 bar1/8" NPT drain
1371/4" NPT100°C - 7 bar1/4" NPT drain
137G1/4" NPT100°C - 7 bar1/4" NPT drain
1381/2" NPT100°C - 7 bar1/4" NPT drain
138G1/2" NPT100°C - 7 bar1/4" NPT drain
1471/4" NPT100°C - 7 bar1/4" NPT drain
147G1/4" NPT100°C - 7 bar1/4" NPT drain
1481/2" NPT100°C - 7 bar1/4" NPT drain
148G1/2" NPT100°C - 7 bar1/4" NPT drain

In-line filters (IL)

4 products, to 340 bar
ModelPortsRatingOptions
116IL1/4" NPT200°C - 340 bar–
126IL1/4" NPT200°C - 340 barCell Filler
136IL1/2" NPT200°C - 100 bar–
146IL1/2" NPT200°C - 100 barCell Filler

Fast loop filters (IL-3)

4 products, to 340 bar
ModelPortsRatingOptions
116IL-31/4" NPT200°C - 340 bar–
126IL-31/4" NPT200°C - 340 bar–
136IL-31/2" NPT, 1/4" NPT200°C - 100 bar–
146IL-31/2" NPT, 1/4" NPT200°C - 100 bar–

PVDF housings (K)

10 products, to 7 bar
ModelPortsRatingOptions
700K1/8" NPT120°C - 7 barNo drain
705K1/4" BSPP120°C - 7 barNo drain
705K1/4" NPT120°C - 7 barNo drain
710K1/4" NPT120°C - 7 barManual
720K1/8" NPT120°C - 7 barNo drain
721K1/8" NPT120°C - 7 barManual
725K1/4" NPT120°C - 7 barNo drain
730K1/4" NPT120°C - 7 barManual
750K1/4" NPT120°C - 7 barNo drain
751K1/4" NPT120°C - 7 barManual

Guardian membrane separators

11 products, to 150 bar
ModelPortsRatingOptions
GMS1001/4" NPT100°C - 100 barM2- High Flow
GMS1051/4" NPT100°C - 100 barM2- High Flow
GMS1051/8" NPT100°C - 100 barM1- Low Flow
GMS105P1/4" NPT100°C - 7 barM2- High Flow
GMS1221/4" NPT100°C - 100 barM2- High Flow
GMS1301/4" NPT100°C - 100 barM2- High Flow
GMS1701/4" NPT100°C - 150 barM2- High Flow
GMS2051/4" NPT100°C - 100 barM2- High Flow
GMS205P1/4" NPT100°C - 7 barM2- High Flow
M2H–––
MB-GMS105–––

Spares and membrane kits

4 products
ModelPortsRatingOptions
GMS170–––
MB-GMS170–––
MT61.M2H–––
MT61.M3–––
Find the exact model

The filter finder takes your gas, pressure, temperature and port and returns the Headline housings rated for it, with the element grade and binder.

Find your filter
Headline brochure: Filters for Instrumentation and Gas Analysis

The main Headline catalogue for sample systems: bonded microfibre, stainless steel and PTFE elements in industry-standard sizes and grades, and the stainless steel, PTFE, PVDF, plastic and aluminium housings that hold them, with dimensions and order codes.

Download the PDF 32 pages, 1.3 MB

Frequently asked questions

Which element grade protects a gas analyser?

Headline builds a Grade 50 coalescing element (50CS) into its GMS170 analyser protector, which removes 99.99+ % of 0.1 micron particles. Grade 40 is finer still. Headline advises the coarsest grade that adequately protects the equipment.

Do Headline elements fit other makes of housing?

Headline makes its elements to industry-standard sizes and grades, so they fit many other manufacturers' housings. Send us your current part number and we confirm the equivalent.

Can you supply the complete sample system?

Yes. Sarvesh designs and builds sample systems in Pune, India: probes, heated lines, the i-Cons conditioner and the analyser, with Headline filters where they belong.