Headline's range of gas analyser sample filters runs to 114 products in these families: 110 and 120 series, 130 and 140 series, 150 and 160 series, low-pressure stainless steel series and in-line filters (IL).
Where the filters go
- At the take-off. A probe filter keeps the bulk of the dust in the process. For hot, wet gas the filter is heated so nothing condenses on it.
- Near the analyser, if response time matters. A fast loop filter sits close to the analyser with a large bypass flow that keeps the element clean; the analyser draws filtered sample from its side port.
- After the cooler. A coalescing filter takes out the fine aerosols a cooler leaves behind. Use a three-port housing so the liquid drains.
- At the analyser inlet. A Guardian membrane separator is the last barrier: gas passes, liquid does not.
Choosing the housing
- Small internal volume keeps the analyser's response fast: the 110 and 120 series hold 20 to 30 cc. Weld-free 316L housings are compliant with NACE MR0175 and MR0103 for sour gas.
- For corrosive samples or gases that must not stick to the filter, use PTFE or all-PVDF housings, with PVDF-bonded or PTFE elements.
- Two-port housings are for particulate filtration of a dry gas; three-port housings carry coalescing and bypass.
Headline products for this duty
Headline lists these 114 products for this application, grouped by family. Open a family to see every model; each links to its card with ports and rating.
110 and 120 series
22 products, to 700 bar
| Model | Ports | Rating | Options |
|---|---|---|---|
| 110 | 1/8" NPT | 200°C - 340 bar | 1/8" NPT drain |
| 110HP | 1/8" NPT | 200°C - 700 bar | 1/8" NPT drain |
| 112 | 1/4" NPT | 200°C - 340 bar | 1/4" NPT drain |
| 112HP | 1/4" NPT | 200°C - 700 bar | 1/4" NPT drain |
| 114 | 1/8" NPT | 200°C - 340 bar | No drain |
| 114HP | 1/8" NPT | 200°C - 700 bar | No drain |
| 116 | 1/4" NPT | 200°C - 340 bar | No drain |
| 116HP | 1/4" NPT | 200°C - 700 bar | No drain |
| 120 | 1/8" NPT | 200°C - 340 bar | 1/8" NPT drain |
| 120B | 1/8" NPT | 200°C - 340 bar | 1/8" NPT drain |
| 120HP | 1/8" NPT | 200°C - 700 bar | 1/8" NPT drain |
| 120S | 1/8" NPT | 200°C - 340 bar | 1/8" NPT drain |
| 122 | 1/4" NPT | 200°C - 340 bar | 1/4" NPT drain |
| 122 SilcoNert | 1/4" NPT | – | – |
| 122B | 1/4" NPT | 200°C - 340 bar | 1/4" NPT drain |
| 122HP | 1/4" NPT | 200°C - 700 bar | 1/4" NPT drain |
| 122S | 1/4" NPT | 200°C - 340 bar | 1/4" NPT drain |
| 124 | 1/8" NPT | 200°C - 340 bar | No drain |
| 124HP | 1/8" NPT | 200°C - 700 bar | No drain |
| 126 | 1/4" NPT | 200°C - 340 bar | No drain |
| 126HP | 1/4" NPT | 200°C - 700 bar | No drain |
| 126S | 1/4" NPT | 200°C - 340 bar | No drain |
130 and 140 series
29 products, to 400 bar
| Model | Ports | Rating | Options |
|---|---|---|---|
| 130 | 1/4" NPT | 200°C - 100 bar | 1/4" NPT drain |
| 130HP | 1/4" NPT | 200°C - 200 bar | 1/4" NPT drain |
| 130VP | 1/4" NPT | 200°C - 400 bar | 1/4" NPT drain |
| 132 | 1/2" NPT | 200°C - 100 bar | 1/4" NPT drain |
| 132-3875 | 1/2" BSPP | 200°C - 100 bar | 1/4" NPT drain |
| 132HP | 1/2" NPT | 200°C - 200 bar | 1/4" NPT drain |
| 132VP | 1/2" NPT | 200°C - 400 bar | 1/4" NPT drain |
| 133 | 1/2" NPT | 200°C - 100 bar | 1/2" NPT drain |
| 134 | 1/4" NPT | 200°C - 100 bar | No drain |
| 134HP | 1/4" NPT | 200°C - 200 bar | No drain |
| 134S | 1/4" NPT | 200°C - 100 bar | No drain |
| 134VP | 1/4" NPT | 200°C - 400 bar | No drain |
| 136 | 1/2" NPT | 200°C - 100 bar | No drain |
| 136HP | 1/2" NPT | 200°C - 200 bar | No drain |
| 136VP | 1/2" NPT | 200°C - 400 bar | No drain |
| 140 | 1/4" NPT | 200°C - 100 bar | 1/4" NPT drain |
| 140HP | 1/4" NPT | 200°C - 200 bar | 1/4" NPT drain |
| 140VP | 1/4" NPT | 200°C - 400 bar | 1/4" NPT drain |
| 142 | 1/2" NPT | 200°C - 100 bar | 1/4" NPT drain |
| 142HP | 1/2" NPT | 200°C - 200 bar | 1/4" NPT drain |
| 142VP | 1/2" NPT | 200°C - 400 bar | 1/4" NPT drain |
| 143 | 1/2" NPT | 200°C - 100 bar | 1/2" NPT drain |
| 143HP | 1/2" NPT | 200°C - 200 bar | 1/2" NPT drain |
| 144 | 1/4" NPT | 200°C - 100 bar | No drain |
| 144HP | 1/4" NPT | 200°C - 200 bar | No drain |
| 144VP | 1/4" NPT | 200°C - 400 bar | No drain |
| 146 | 1/2" NPT | 200°C - 100 bar | No drain |
| 146HP | 1/2" NPT | 200°C - 200 bar | No drain |
| 146VP | 1/2" NPT | 200°C - 400 bar | No drain |
150 and 160 series
18 products, to 400 bar
| Model | Ports | Rating | Options |
|---|---|---|---|
| 150 | 1" NPT | 200°C - 100 bar | 1/4" NPT drain |
| 150HP | 1" NPT | 200°C - 200 bar | 1/4" NPT drain |
| 150VP | 1" NPT | 200°C - 400 bar | 1/4" NPT drain |
| 151 | 1 1/2" NPT | 200°C - 100 bar | 1/4" NPT drain |
| 151HP | 1 1/2" NPT | 200°C - 200 bar | 1/4" NPT drain |
| 151VP | 1 1/2" NPT | 200°C - 400 bar | 1/4" NPT drain |
| 152 | 2" NPT | 200°C - 100 bar | 1/4" NPT drain |
| 152HP | 2" NPT | 200°C - 200 bar | 1/4" NPT drain |
| 152VP | 2" NPT | 200°C - 400 bar | 1/4" NPT drain |
| 160 | 1" NPT | 200°C - 100 bar | 1/4" NPT drain |
| 160HP | 1" NPT | 200°C - 200 bar | 1/4" NPT drain |
| 160VP | 1" NPT | 200°C - 400 bar | 1/4" NPT drain |
| 161 | 1 1/2" NPT | 200°C - 100 bar | 1/4" NPT drain |
| 161HP | 1 1/2" NPT | 200°C - 200 bar | 1/4" NPT drain |
| 161VP | 1 1/2" NPT | 200°C - 400 bar | 1/4" NPT drain |
| 162 | 2" NPT | 200°C - 100 bar | 1/4" NPT drain |
| 162HP | 2" NPT | 200°C - 200 bar | 1/4" NPT drain |
| 162VP | 2" NPT | 200°C - 400 bar | 1/4" NPT drain |
Low-pressure stainless steel series
12 products, to 7 bar
| Model | Ports | Rating | Options |
|---|---|---|---|
| 117 | 1/4" NPT | 100°C - 7 bar | 1/8" NPT drain |
| 117G | 1/4" NPT | 100°C - 7 bar | 1/8" NPT drain |
| 127 | 1/4" NPT | 100°C - 7 bar | 1/8" NPT drain |
| 127G | 1/4" NPT | 100°C - 7 bar | 1/8" NPT drain |
| 137 | 1/4" NPT | 100°C - 7 bar | 1/4" NPT drain |
| 137G | 1/4" NPT | 100°C - 7 bar | 1/4" NPT drain |
| 138 | 1/2" NPT | 100°C - 7 bar | 1/4" NPT drain |
| 138G | 1/2" NPT | 100°C - 7 bar | 1/4" NPT drain |
| 147 | 1/4" NPT | 100°C - 7 bar | 1/4" NPT drain |
| 147G | 1/4" NPT | 100°C - 7 bar | 1/4" NPT drain |
| 148 | 1/2" NPT | 100°C - 7 bar | 1/4" NPT drain |
| 148G | 1/2" NPT | 100°C - 7 bar | 1/4" NPT drain |
In-line filters (IL)
4 products, to 340 bar
Fast loop filters (IL-3)
4 products, to 340 bar
PVDF housings (K)
10 products, to 7 bar
| Model | Ports | Rating | Options |
|---|---|---|---|
| 700K | 1/8" NPT | 120°C - 7 bar | No drain |
| 705K | 1/4" BSPP | 120°C - 7 bar | No drain |
| 705K | 1/4" NPT | 120°C - 7 bar | No drain |
| 710K | 1/4" NPT | 120°C - 7 bar | Manual |
| 720K | 1/8" NPT | 120°C - 7 bar | No drain |
| 721K | 1/8" NPT | 120°C - 7 bar | Manual |
| 725K | 1/4" NPT | 120°C - 7 bar | No drain |
| 730K | 1/4" NPT | 120°C - 7 bar | Manual |
| 750K | 1/4" NPT | 120°C - 7 bar | No drain |
| 751K | 1/4" NPT | 120°C - 7 bar | Manual |
Guardian membrane separators
11 products, to 150 bar
| Model | Ports | Rating | Options |
|---|---|---|---|
| GMS100 | 1/4" NPT | 100°C - 100 bar | M2- High Flow |
| GMS105 | 1/4" NPT | 100°C - 100 bar | M2- High Flow |
| GMS105 | 1/8" NPT | 100°C - 100 bar | M1- Low Flow |
| GMS105P | 1/4" NPT | 100°C - 7 bar | M2- High Flow |
| GMS122 | 1/4" NPT | 100°C - 100 bar | M2- High Flow |
| GMS130 | 1/4" NPT | 100°C - 100 bar | M2- High Flow |
| GMS170 | 1/4" NPT | 100°C - 150 bar | M2- High Flow |
| GMS205 | 1/4" NPT | 100°C - 100 bar | M2- High Flow |
| GMS205P | 1/4" NPT | 100°C - 7 bar | M2- High Flow |
| M2H | – | – | – |
| MB-GMS105 | – | – | – |
The filter finder takes your gas, pressure, temperature and port and returns the Headline housings rated for it, with the element grade and binder.
Related detail
The main Headline catalogue for sample systems: bonded microfibre, stainless steel and PTFE elements in industry-standard sizes and grades, and the stainless steel, PTFE, PVDF, plastic and aluminium housings that hold them, with dimensions and order codes.
Frequently asked questions
Which element grade protects a gas analyser?
Headline builds a Grade 50 coalescing element (50CS) into its GMS170 analyser protector, which removes 99.99+ % of 0.1 micron particles. Grade 40 is finer still. Headline advises the coarsest grade that adequately protects the equipment.
Do Headline elements fit other makes of housing?
Headline makes its elements to industry-standard sizes and grades, so they fit many other manufacturers' housings. Send us your current part number and we confirm the equivalent.
Can you supply the complete sample system?
Yes. Sarvesh designs and builds sample systems in Pune, India: probes, heated lines, the i-Cons conditioner and the analyser, with Headline filters where they belong.