Choose the element grade, then the element size whose air flow at your line pressure covers your maximum flow. At 7 bar and a 0.1 bar pressure drop, for example, a grade 50 element passes 10 Nm³/h in the 12-32 size and 35 Nm³/h in the 25-64 size. The calculator below does this for any grade, gas and pressure.
What decides the filter
Headline selects a housing from six facts about the duty:
- Pressure and temperature: of the gas at the filter housing.
- Composition: the chemical and physical make-up of the gas.
- Contaminants: what has to be removed: dust, liquid aerosol, slugs of liquid, a vapour.
- Duty: inlet, particulate, coalescing or fast loop.
- Flow and line size: the flow rate, the line size and the level of filtration needed.
- Priorities: the relative importance of cost, response time, ease of service and service interval.
The first three set the materials of the housing, the element and the seals. The duty sets the port configuration. Flow, line size and priorities set the size.
Port configuration
| Ports | Duty | How it works |
|---|---|---|
| One port | Inlet filter | Sits at the open end of a sample line, for example the inlet of an ambient monitor. |
| Two ports, in-line | Particulate | Gas passes straight through the element. For dust in a gas that is already dry. |
| Two ports, T | Particulate | Inlet and outlet in the head, element in the bowl. For dust in a dry gas where the line layout suits a T. |
| Three ports | Coalescing | The third port drains the liquid the element collects, by hand or through an automatic drain. |
| Three ports | Fast loop | A large bypass flow sweeps the element clean while the analyser draws filtered gas from the side port. |
Small filter or large filter
Size is always a compromise. A small filter gives fast response, smallest space, lowest cost, least adsorption of the measured gas. A large filter gives long service interval and low pressure drop. Choose by which matters more in your application.
Sizing calculator
Flow rate tables
Headline's tables for disposable glass fibre elements, with the comparable stainless steel mesh (SS) and PTFE (PT) element grades. Flow rates are for air at 20 °C and are generally proportional to the pressure drop: if a starting drop of 0.2 bar is acceptable, they double. In-line adsorbers and vapour adsorption cartridges pass the same flow as a grade 50 element of the same size.
Elements 12-32-xx (SS-110-xx, PT-110-xx): 110 series
| Grade | SS | PT | 0.1 | 1 | 2 | 4 | 7 | 10 | 16 | 100 | 200 | 400 | 700 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 40, 40K, 40S | 01 | – | 0.7 | 1.3 | 2 | 3.3 | 5.3 | 7.3 | 11 | 67 | 135 | 225 | 450 |
| 50, 50K, 50S, 50C | 03 | 03 | 1.4 | 2.6 | 3.9 | 6.4 | 10 | 14 | 22 | 130 | 260 | 440 | 880 |
| 60, 60K, 60S, 60C | 10 | 10 | 3.9 | 7 | 11 | 18 | 28 | 39 | 60 | 350 | 700 | 1200 | 2400 |
| 70, 70K, 70S, 70C | 25 | 25 | 5.3 | 9.5 | 14 | 24 | 38 | 52 | 81 | 480 | 960 | 1620 | 3240 |
| 80, 80K, 80S, 80C | 100 | – | 5.9 | 11 | 16 | 27 | 43 | 60 | 92 | 550 | 1090 | 1850 | 3700 |
Air flow in Nm³/h at the line pressure in bar shown at the top of each column, with a 0.1 bar pressure drop. Housings that take this element: 110 and 120 series, low-pressure stainless steel, in-line and fast loop, polypropylene and nylon, aluminium, instrument air coalescing.
Elements 12-57-xx (SS-120-xx, PT-120-xx): 120 series
| Grade | SS | PT | 0.1 | 1 | 2 | 4 | 7 | 10 | 16 | 100 | 200 | 400 | 700 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 40, 40K, 40S | 01 | – | 1.2 | 2.3 | 3.4 | 5.6 | 9 | 12 | 19 | 115 | 225 | 385 | 770 |
| 50, 50K, 50S, 50C | 03 | 03 | 2.5 | 4.5 | 6.7 | 11 | 18 | 25 | 38 | 225 | 450 | 795 | 1590 |
| 60, 60K, 60S, 60C | 10 | 10 | 5.1 | 9.3 | 14 | 23 | 37 | 51 | 79 | 470 | 940 | 1590 | 3180 |
| 70, 70K, 70S, 70C | 25 | 25 | 6.1 | 11 | 17 | 28 | 45 | 61 | 95 | 560 | 1120 | 1900 | 3800 |
| 80, 80K, 80S, 80C | 100 | – | 6.8 | 13 | 19 | 31 | 50 | 69 | 106 | 630 | 1260 | 2130 | 4250 |
Air flow in Nm³/h at the line pressure in bar shown at the top of each column, with a 0.1 bar pressure drop. Housings that take this element: 110 and 120 series, low-pressure stainless steel, in-line and fast loop, PTFE and PVDF, polypropylene and nylon, aluminium.
Elements 25-64-xx (SS-130-xx, PT-130-xx): 130 series
| Grade | SS | PT | 0.1 | 1 | 2 | 4 | 7 | 10 | 16 | 100 | 200 | 300 | 400 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 40, 40K, 40S | 01 | – | 2.6 | 4.7 | 7 | 12 | 19 | 26 | 40 | 240 | 470 | 645 | 820 |
| 50, 50K, 50S, 50C | 03 | 03 | 4.8 | 9 | 13 | 22 | 35 | 48 | 75 | 440 | 880 | 1210 | 1540 |
| 60, 60K, 60S, 60C | 10 | 10 | 8.5 | 16 | 23 | 39 | 62 | 85 | 130 | 780 | 1560 | 2150 | 2730 |
| 70, 70K, 70S, 70C | 25 | 25 | 10 | 18 | 27 | 44 | 74 | 97 | 150 | 890 | 1780 | 2450 | 2730* |
| 80, 80K, 80S, 80C | 100 | – | 11 | 19 | 29 | 48 | 77 | 105 | 165 | 970 | 1970 | 2690 | 3400 |
Air flow in Nm³/h at the line pressure in bar shown at the top of each column, with a 0.1 bar pressure drop. Housings that take this element: 130 and 140 series, low-pressure stainless steel, in-line and fast loop, heatable, PTFE and PVDF, polypropylene and nylon, aluminium, instrument air coalescing. * As printed in Headline's bulletin; out of step with the grades either side, so we confirm it for your duty.
Elements 25-178-xx (SS-140-xx, PT-140-xx): 140 series
| Grade | SS | PT | 0.1 | 1 | 2 | 4 | 7 | 10 | 16 | 100 | 200 | 300 | 400 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 40, 40K, 40S | 01 | – | 6 | 11 | 16 | 26 | 42 | 58 | 90 | 530 | 1060 | 1460 | 1850 |
| 50, 50K, 50S, 50C | 03 | 03 | 9 | 17 | 25 | 42 | 67 | 92 | 140 | 840 | 1680 | 2320 | 2950 |
| 60, 60K, 60S, 60C | 10 | 10 | 11 | 20 | 30 | 49 | 79 | 110 | 170 | 990 | 1980 | 2720 | 3460 |
| 70, 70K, 70S, 70C | 25 | 25 | 12 | 21 | 32 | 53 | 84 | 115 | 180 | 1680* | 2120 | 2920 | 3710 |
| 80, 80K, 80S, 80C | 100 | – | 13 | 23 | 35 | 58 | 93 | 130 | 200 | 1180 | 2360 | 3250 | 4130 |
Air flow in Nm³/h at the line pressure in bar shown at the top of each column, with a 0.1 bar pressure drop. Housings that take this element: 130 and 140 series, low-pressure stainless steel, in-line and fast loop, heatable, PTFE and PVDF, polypropylene and nylon, aluminium, instrument air coalescing. * As printed in Headline's bulletin; out of step with the grades either side, so we confirm it for your duty.
Source: Headline Filters bulletin HFL201, Filters for Instrumentation and Gas Analysis.
150 and 160 series, 1 to 2 inch lines
From Headline's process gas bulletin HFL203, at a 0.15 bar pressure drop and line pressures to 10 bar. The calculator above includes them.
150 series (51-230 elements)
| Line pressure, bar g | Grade 30 | Grade 40 | Grade 50 | Grade 60 | Grade 70 |
|---|---|---|---|---|---|
| 0 | 12 | 22 | 38 | 89 | 101 |
| 1 | 24 | 44 | 76 | 178 | 202 |
| 2 | 36 | 66 | 113 | 268 | 303 |
| 3 | 48 | 83 | 151 | 357 | 404 |
| 4 | 59 | 110 | 189 | 446 | 505 |
| 5 | 71 | 133 | 227 | 535 | 607 |
| 6 | 83 | 155 | 265 | 624 | 708 |
| 7 | 95 | 177 | 302 | 714 | 809 |
| 8 | 107 | 199 | 340 | 803 | 910 |
| 9 | 119 | 221 | 378 | 892 | 1010 |
| 10 | 131 | 243 | 416 | 981 | 1110 |
| Water, l/h | 214 | 400 | 705 | 1770 | 1910 |
Air at 20 °C in Nm³/h, and water in l/h, with a 0.15 bar pressure drop.
160 series (51-476 elements)
| Line pressure, bar g | Grade 30 | Grade 40 | Grade 50 | Grade 60 | Grade 70 |
|---|---|---|---|---|---|
| 0 | 25 | 44 | 65 | 107 | 114 |
| 1 | 49 | 87 | 129 | 213 | 228 |
| 2 | 74 | 131 | 194 | 320 | 341 |
| 3 | 99 | 175 | 258 | 426 | 455 |
| 4 | 123 | 219 | 323 | 533 | 569 |
| 5 | 148 | 262 | 387 | 640 | 683 |
| 6 | 172 | 306 | 152* | 746 | 797 |
| 7 | 197 | 350 | 516 | 853 | 911 |
| 8 | 222 | 394 | 581 | 960 | 1020 |
| 9 | 246 | 497* | 646 | 1070 | 1140 |
| 10 | 271 | 481 | 710 | 1170 | 1250 |
| Water, l/h | 410 | 780 | 1200 | 2070 | 2240 |
Air at 20 °C in Nm³/h, and water in l/h, with a 0.15 bar pressure drop. * Printed as 152 for grade 50 at 6 bar; the bulletin's own s.c.f.m. figure gives 452 Nm³/h, which the calculator uses. * Printed as 497 for grade 40 at 9 bar; the bulletin's own s.c.f.m. figure gives 437 Nm³/h, which the calculator uses.
The accessories that go with a gas sample filter: for slugs of liquid, washing a sample, draining under vacuum or pressure, and open-ended inlets.
The main Headline catalogue for sample systems: bonded microfibre, stainless steel and PTFE elements in industry-standard sizes and grades, and the stainless steel, PTFE, PVDF, plastic and aluminium housings that hold them, with dimensions and order codes.
Frequently asked questions
How do I size a Headline filter for my flow?
Find the flow your element size passes at your line pressure and grade with a 0.1 bar pressure drop, from the tables or the calculator on this page, and choose an element size that passes your maximum flow. If a 0.2 bar starting pressure drop is acceptable, the flow roughly doubles.
Are the flow rates for air only?
The tables are for air at 20 °C. For other gases Headline derives the flow from relative viscosity; the calculator scales by the ratio of the viscosity of air to that of your gas. We confirm the figure for your gas before quoting.
Why does a coarser grade pass more flow?
A coarser grade has larger pores, so the same pressure drop pushes more gas through. Headline advises the coarsest grade that adequately protects the equipment: it is cheaper to run and lasts longer.
Do vapour adsorption cartridges and in-line adsorbers follow these tables?
Headline gives them the same flow as a grade 50 element of the same size, but for adsorption the volume of adsorbent and the contact time matter more than the flow.
What about the 150 and 160 series?
They take larger 51 mm elements that are not in these tables. Send us the flow and pressure and we size them with Headline.