Headline filter positions in compressed air and pneumatic equipment: air inlet to the machine, critical air, oil vapour, point of use and high pressure air. The table below gives the Headline products for each position.
For: Air dryer and air treatment builders, instrument air panel builders, pneumatic machinery, laser cutting and packaging machine builders.
Where Headline filters go in your equipment
| Position | What the filter does | Headline products |
|---|---|---|
| Air inlet to the machine | Grade 70C coalescer for general clean air: valves, cylinders, air tools and motors | Compressed air filters Aluminium housings |
| Critical air | Grade 50C for air bearings, spray coating, instrumentation, lasers and food contact | Instrument air coalescing filters Coalescing filters |
| Oil vapour | Grade CC activated carbon after the 50C coalescer | Vapour removal adsorbers |
| Point of use | Brass housings at each instrument or positioner, resistant to a salt-water atmosphere | Brass filter housings |
| High pressure air | Aluminium high-pressure housings to 70 bar, or stainless steel above that | Aluminium housings 130 and 140 series |
Design notes
- Aluminium housings with a polycarbonate bowl are rated to 10 bar at 50 °C; with an aluminium bowl, to 16 bar at 120 °C. Automatic float drains need at least 1 bar.
- Keep polycarbonate bowls away from synthetic lubricants and solvents.
- The C-type element needs no end caps or support core; at a change only the filter medium is thrown away, which keeps your customer's running cost down.
- An optional differential pressure indicator shows when the element reaches 0.7 bar and needs changing.
Selection, Headline's data for your drawing, and equivalents for filters you use now are covered on Headline filters for OEMs.
The filter finder takes the gas, pressure, temperature and port and returns the Headline housings rated for it, with the element grade.
Related Headline collections
Frequently asked questions
Which grade should a machine's air inlet filter use?
Grade 70C for general clean air. Use grade 50C, with a 70C prefilter, where the machine has air bearings, spray coating, instrumentation, lasers or food contact.
Can a coalescing filter replace an air dryer?
No. A coalescer removes liquid water and oil aerosols. Water vapour needs a dryer.