Headline filter positions in gas generators and electrolysers: feed air, oil vapour in the feed, product gas, purity analyser sample and high-pressure filling. The table below gives the Headline products for each position.
For: Nitrogen and oxygen generator makers (PSA and membrane), hydrogen generator and electrolyser builders.
Where Headline filters go in your equipment
| Position | What the filter does | Headline products |
|---|---|---|
| Feed air | Grade 70C then grade 50C coalescers remove oil and water aerosols down to 0.1 micron | Compressed air filters Aluminium housings Instrument air coalescing filters |
| Oil vapour in the feed | A grade CC activated carbon cartridge after the 50C coalescer takes out oil vapour | Vapour removal adsorbers Coalescing filters |
| Product gas | A particulate filter on the outlet, in stainless steel rated for the outlet pressure | 110 and 120 series 130 and 140 series High-purity gas filters |
| Purity analyser sample | Stop liquid water and particles reaching the oxygen or hydrogen sensor | Guardian membrane separators Gas analyser sample filters |
| High-pressure filling | Stainless housings for cylinder filling and storage, to 400 bar, or 700 bar in the 110 and 120 HP versions | 130 and 140 series 110 and 120 series |
Design notes
- Always fit a grade 70C prefilter ahead of a grade 50C final filter, and a 50C coalescer ahead of any CC vapour cartridge.
- Never fit a filter with ports smaller than the line, and size it for the maximum flow: above its rated flow a coalescer loses efficiency.
- A coalescing element starts below 0.15 bar dry pressure drop; Headline recommends a change at 0.7 bar. A differential pressure indicator tells your customer when.
- Hydrogen from an electrolyser is saturated with water. Keep the sample to the analyser free of liquid with a coalescing filter and a membrane separator.
Selection, Headline's data for your drawing, and equivalents for filters you use now are covered on Headline filters for OEMs.
The filter finder takes the gas, pressure, temperature and port and returns the Headline housings rated for it, with the element grade.
Related Headline collections
Sarvesh Analytics designs and builds ACCURRA gas analysers in Pune, India, for OEMs and system builders: one ordering code, 4–20 mA, Modbus and alarm relays.
Frequently asked questions
Which grade protects a nitrogen membrane or PSA bed?
Headline specifies grade 50C for the most demanding air duties, with a grade 70C prefilter. Add a grade CC cartridge after the 50C to take out oil vapour.
Do you supply the purity analyser as well?
Yes. Sarvesh Analytics designs and builds ACCURRA oxygen and thermal conductivity analysers in Pune, India, for nitrogen, oxygen and hydrogen generators.