A coalescing filter merges fine oil and water droplets into drops that drain away, and traps particles at the same time. Headline's grade 50 coalescing elements remove 99.99+ % of 0.1 micron particles and aerosols, in three-port drained housings from small 316L analyser filters to 2 inch lines rated to 400 bar.
How a coalescing filter works
Headline coalescing elements are bonded borosilicate glass microfibre, more than 90 percent void volume, so they filter efficiently at a low pressure drop and last a long time. Gas flows through the element; fine oil and water aerosols touch the fibres, join into larger drops and run down into the bowl, where they drain away. Particles are removed with the same efficiency, so one element does both jobs.
Because liquid collects, a coalescing filter always needs a housing with a drain or bypass port. A particulate filter, by contrast, is for gas that is already dry.
Element grades
| Grade | Removal of 0.1 micron particles |
|---|---|
| 40C / 40CS | 99.9999+ % |
| 50C / 50CS | 99.99+ % |
| 60C / 60CS | 99.5+ % |
| 70C / 70CS | 95+ % |
| 80C / 80CS | 75+ % |
Grades are rated by removal of 0.1 micron particles. Headline advises the coarsest grade that adequately protects the equipment; where the liquid load is heavy, put a coarser grade ahead of a finer one.
C or CS: the binder
- C (PVDF binder). For corrosive and non-corrosive gases, up to 150 °C.
- CS (silica binder). Completely inorganic, up to 500 °C and where solvents are present.
The part number gives the inside diameter and length in millimetres, then the grade and binder: 25-64-50C is 25 mm inside, 64 mm long, Grade 50, PVDF binder. Each housing takes one element size, listed on its series page.
Housings for coalescing duty
Every Headline housing below has a drain or bypass port. Stainless steel three-port housings carry coalescing filtration and bypass in analyser and process lines; aluminium 300 series filters hold more liquid and can have an automatic float drain; plastic housings have a manual twist drain.
| Series | Coalescing models | Material | Max temperature and pressure |
|---|---|---|---|
| 110 and 120 series | 12 | Stainless steel 316 | 200 to 200 °C, 340 to 700 bar |
| 150 and 160 series | 18 | Stainless steel 316 | 200 to 200 °C, 100 to 400 bar |
| 130 and 140 series | 16 | Stainless steel 316 | 200 to 200 °C, 100 to 400 bar |
| Brass housings (B) | 3 | Brass | 120 to 120 °C, 16 to 16 bar |
| 380 series aluminium high-pressure housings | 2 | Aluminium | 120 to 120 °C, 16 to 16 bar |
| 300 series aluminium coalescing housings | 36 | Aluminium | 50 to 120 °C, 10 to 16 bar |
| 200 series aluminium housings | 16 | Aluminium | 50 to 120 °C, 10 to 16 bar |
| PTFE housings | 9 | PTFE | 100 to 150 °C, 7 to 7 bar |
| Polypropylene housings (P, PC) | 13 | Plastic | 50 to 50 °C, 7 to 7 bar |
| Nylon housings (N, NC) | 14 | Plastic | 50 to 50 °C, 7 to 7 bar |
| 770 series | 3 | Plastic | 50 to 50 °C, 7 to 7 bar |
| PVDF housings (K) | 5 | Plastic | 120 to 120 °C, 7 to 7 bar |
- 150 and 160 series
- 130 and 140 series
- 110 and 120 series
- PTFE housings
- Polypropylene housings (P, PC)
- Nylon housings (N, NC)
- 770 series
- PVDF housings (K)
- Brass housings (B)
- 380 series aluminium high-pressure housings
- 300 series aluminium coalescing housings
- 200 series aluminium housings
Where coalescing filters are used
- Instrument and compressed air. Water, oil and dirt out before instruments, valves and actuators.
- Natural gas and fuel gas. Clean gas for fuel gas metering and gas filtration.
- Gas analyser sample lines. Aerosols out before the sensor, with a Guardian membrane separator as the last barrier against liquid.
- Vacuum pumps. Oil mist out of the exhaust, with silica-bonded CS elements.
The filter finder returns the Headline housings rated for your pressure, temperature and port, with the element grade and binder.
Related detail
- Filter sizing calculator and flow rates
- Compressed air housings, flow rates and sizing calculator
- Coalescing filter regulators
- Activated carbon cartridges for oil vapour
Headline brochures
Headline's own brochures for these products, with dimensions and order codes.
- Filters for Compressed AirCoalescing filters for compressed and instrument air: how the C-type element works, which grade to choose, when to change it, the aluminium, brass and stainless steel housings, drains, indicators and vapour adsorption cartridges.PDF, 16 pages, 499 KB
- Filters for Instrumentation and Gas AnalysisThe main Headline catalogue for sample systems: bonded microfibre, stainless steel and PTFE elements in industry-standard sizes and grades, and the stainless steel, PTFE, PVDF, plastic and aluminium housings that hold them, with dimensions and order codes.PDF, 32 pages, 1.3 MB
- Filters for Vacuum PumpsOil mist filters for the exhaust of oil-sealed vacuum pumps: the CS-type coalescing element, aluminium and stainless steel housings sized by pump flow from 5 to 765 m³/h, and installation guidance.PDF, 8 pages, 370 KB
All Headline brochures and application notes
Frequently asked questions
What is the difference between a coalescing and a particulate filter?
A particulate filter removes solid particles from a gas that is already dry. A coalescing filter removes fine liquid aerosols as well: it merges oil and water mist into drops that drain from the bowl, and takes out particles with the same efficiency.
Which grade should I use?
Headline advises the coarsest grade that adequately protects the equipment. Grade 80C is the high-flow grade Headline fits in its B360 instrument-air filters for heavily saturated air; Grade 50 is the grade it builds into the GMS170 analyser protector as 50CS; Grade 40 is the finest.
C or CS element?
C elements use a PVDF binder, for corrosive and non-corrosive gases up to 150 °C. CS elements use a silica binder, completely inorganic, for temperatures up to 500 °C and where solvents are present.
Does a coalescing filter need a drain?
Yes. The coalesced liquid collects in the bowl, so use a housing with a drain or bypass port: a three-port stainless steel housing, or a manual or automatic float drain on aluminium and plastic housings. The automatic float drain works above 12 psi.
Can it protect a gas analyser from liquid?
It removes aerosols. For a final barrier against liquid carry-over at the analyser inlet, add a Guardian membrane separator after it; the GMS170 combines a 50CS coalescing element and a PTFE membrane in one housing.
Can I buy Headline coalescing filters in India?
Yes. Sarvesh Analytics supplies Headline housings and elements across India as Headline's exclusive representative for the Indian subcontinent.