Headline filter positions in gas analysers and sample systems: probe or take-off, fast loop, after the cooler, analyser inlet, corrosive or reactive sample and interfering vapour. The table below gives the Headline products for each position.
For: Gas analyser makers, analyser shelter and sample panel builders, CEMS integrators.
Where Headline filters go in your equipment
| Position | What the filter does | Headline products |
|---|---|---|
| Probe or take-off | Keep the bulk of the dust in the process; heated where the gas is hot and wet | Heatable H130 and H140 130 and 140 series Emission monitoring filters |
| Fast loop | Clean sample near the analyser with a 4 to 1 bypass that keeps the element clean | In-line and fast loop filters |
| After the cooler | Coalesce the fine aerosols a cooler leaves behind, in a three-port drained housing | 110 and 120 series 130 and 140 series Filter elements |
| Analyser inlet | Last barrier: gas passes, liquid does not | Guardian membrane separators |
| Corrosive or reactive sample | PTFE or all-PVDF wetted parts, PVDF-bonded or PTFE elements | PTFE and PVDF housings |
| Interfering vapour | Adsorb moisture, hydrocarbons or acid gases ahead of a sensor | Disposable in-line filters and adsorbers Vapour removal adsorbers |
Design notes
- The 110 and 120 series hold 20 to 30 cc, so a sample line sweeps them quickly. Weld-free 316L, NACE MR0175 and MR0103 compliant, to 340 bar or 700 bar (HP).
- Use two-port housings for particulate filtration of a dry gas, three-port housings for coalescing and bypass.
- Headline builds a grade 50 coalescing element (50CS) into its GMS170 analyser protector; it removes 99.99+ % of 0.1 micron particles.
- Specify the coarsest grade that protects the analyser: it lasts longer between changes, which your customer will notice.
Selection, Headline's data for your drawing, and equivalents for filters you use now are covered on Headline filters for OEMs.
The filter finder takes the gas, pressure, temperature and port and returns the Headline housings rated for it, with the element grade.
Related Headline collections
- Gas analyser sample filters
- Emission monitoring filters
- High-purity gas filters
- Vapour removal adsorbers
Sarvesh Analytics designs and builds ACCURRA gas analysers in Pune, India, for OEMs and system builders: one ordering code, 4–20 mA, Modbus and alarm relays.
Frequently asked questions
Which Headline filter is best at an analyser inlet?
A Guardian membrane separator is the usual last barrier, because it stops liquid while passing gas. Headline does not recommend it for hydrofluoric acid.
How do I keep analyser response time short?
Use the smallest housing that handles the flow, such as the 110 and 120 series at 20 to 30 cc, or a fast loop filter that flushes itself with a bypass flow.