ACCURRA-S · Model M015

ACCURRA-S M015 dew point analyser

ACCURRA-S M015 measures dew point over -80 to +20 °C dp (minimum range -80 to 0 °C dp) with a ceramic sensor. It is a safe-area, 19-inch rack or panel analyser with an isolated 4–20 mA output, relays and Modbus, made by Sarvesh in Pune, India.

Quick answer

ACCURRA-S M015 measures dew point from -80 to +20 °C dp (minimum range -80 to 0 °C dp), with a ceramic sensor: accuracy +/- 2 °C dp, response 2 min at 5 LPM, dry to wet. Ordering code ACCURRA-S-M015 followed by the second component and options.

Figures from the ACCURRA-S datasheet (SAPL/PDS/ACCURRA-S-10/25-Aug)

Specifications

ItemSpecificationNotes
MeasuresMoisture / dew point
Range-80 to +20 °C dpConfigurable within this span; dual-range 4–20 mA output
Minimum range-80 to 0 °C dp
SensorCeramic sensor
Display resolution1 °C
Intrinsic error (accuracy)+/- 2 °C dp
Repeatability1 °C dp
Response T902 min at 5 LPM, dry to wetAt 1 LPM unless stated
NotesSensor bypass valve supplied; field calibration not possible

From datasheet SAPL/PDS/ACCURRA-S-10/25-Aug. Specifications may change as products improve.

Built into every ACCURRA-S

ItemSpecificationNotes
DisplayBacklit LCD, 4 lines x 20 characters
Analog output1 x 4–20 mA isolated, max load 500 ohm, dual rangeRange freely selectable over the full measurement range
Relays6 x SPST rated 1 A 230 V AC, all failsafeAlarm 1, Alarm 2, fault, sample pump or range ID, two for auto-calibration valves
CommunicationModbus RTU over RS 485Read measured value, status, set-up and history; write auto-calibration start and set-up
Enclosure19 inch rack or panel; 134 H x 483 W x 180 (short) or 280 (long) D mmIP 20, safe area only; net about 6 kg, gross about 8 kg
Power100 to 240 V AC, 50/60 Hz, 45 W
Inlet and outlet1/4 inch OD SS316
Ambient5 to 40 °C; below 90 % RH non-condensingStorage 0 to 50 °C

Options for this model

  • Auto calibration: not available on this model.
  • Sample pump: no internal sample pump on this model; a relay output can drive an external pump.
  • Range ID relay: shows which of the two 4–20 mA ranges is active; it shares a relay with the sample pump, so choose one.
  • A sensor bypass valve is supplied, to isolate the sensor during purging or upsets.
  • Field calibration is not possible on M015; ask us how the sensor is checked and recalibrated.

Build the part number Write the specification

Dual measurement

The M015 can share an ACCURRA-S enclosure with a second sensor in series, each with its own electronics, 4–20 mA output, relays and Modbus address. The catalogue lists it with 3015 (oxygen, trace). Other pairs are possible on request.

Sample at the analyser

  • The sample gas should be non-corrosive, non-toxic, non-flammable, non-condensing and dry, and free from entrained oil.
  • Sample pressure 2 to 10 psig maximum, regulated externally. Recommended flow 1 LPM.
  • Dust or particulate below 3 micron; the built-in fine filter handles light loads, and heavier dust needs an upstream filter.
  • Materials in contact with sample: SS316, Viton, PTFE, glass, aluminium and acrylic.
  • Sample temperature 5 to 45 °C, and a sample dew point at least 5 °C below the lowest ambient temperature.

Where it is used

Application notes where M015 is part of the recommended system:

Frequently asked questions

What range does ACCURRA-S M015 measure?

-80 to +20 °C dp, with a minimum range of -80 to 0 °C dp.

Does M015 have auto calibration and an internal sample pump?

Auto calibration: not available on this model. Sample pump: no internal sample pump on this model; a relay output can drive an external pump.

What is the part number?

It starts ACCURRA-S-M015. Positions 5 to 8 are a second gas or XXXX, then the power supply, the range ID or pump relay, and auto calibration. The part number builder writes the full code and checks it against the catalogue.